Global one-stop procurement platform for industrial spare parts.
support01@okmarts.com service@okmarts.com hydraulic@okmarts.com
Okmarts.com Online Store, Refrigeration Compressor Price, O&Kmarts Logo
Max 200 characters
Display the website inEN
EN
translate to EN
EN
translate to ES
ES
translate to العربية
العربية
All
Omron
Omron
  • Encoder
    Encoder
  • Light Curtain
    Light Curtain
  • VFD
    VFD
  • Sensor
    Sensor
  • PLC
    PLC
  • Transformer
    Transformer
  • Optical Fiber Amplifier
    Optical Fiber Amplifier
  • Fan
    Fan
  • Digital Display Controller
    Digital Display Controller
  • Module
    Module
  • Battery
    Battery
  • Switch
    Switch
DANFOSS
DANFOSS
  • Switch
    Switch
CHANTO
CHANTO
  • Air Cylinder
    Air Cylinder
  • Switch
    Switch
ERSCE
ERSCE
  • Switch
    Switch
Trane
Trane
  • Switch
    Switch
  • Sensor
    Sensor
Kromschroder
Kromschroder
  • Proportional Valve
    Proportional Valve
  • Proportional Valve
    Proportional Valve
  • Transformer
    Transformer
  • Flame Detector
    Flame Detector
  • Safety Valve
    Safety Valve
  • Combustion Controller
    Combustion Controller
  • Pressure Gauge
    Pressure Gauge
  • Switch
    Switch
  • Solenoid Valve
    Solenoid Valve
All Brands
All Brands
    • a
    • b
    • c
    • d
    • e
    • f
    • g
    • h
    • i
    • j
    • k
    • l
    • m
    • n
    • o
    • p
    • q
    • r
    • s
    • t
    • u
    • v
    • w
    • x
    • y
    • z
    • 3
    • 7
      Top Picks
      • FEMA Switch DNS16-201
      1/1
      FEMA Switch DNS16-201
      $ 1,373 .08

      ✔ In Stock (Can ship in 5-7 days)

      Quantity
      MOQ : 1
      Payment Methods
      T/T pay VISA pay mastercard pay Diners Club pay Discover pay JCB pay American Express pay Stripe pay PayPal pay Google pay Apple pay Link pay venmo pay
      • Online Support 24/7

      • 12 Months Warranty for New Products

      • 30 Days Money Back Guarantee

      • Specifications
      • Q&A
      • Reviews
      Pressure switches of the DNS series are suitable for monitoring and controlling pressures in chemical plants, process engineering and any situation where the pressure of aggressive liquids and gases must be monitored.

      Ask questions

      (0/1,200)

      Max 1200 characters

      • Q: How can I track my order?

        A: Once your order is shipped, you will receive a confirmation email with tracking information. You can use this information to track your order through the logistics provider's website.

      • Q: How can I apply for a purchase invoice?

        A: On the checkout page, you can select the option for an invoice and fill in the relevant invoice information. We will provide you with the corresponding invoice according to your request.

      • Q: What should I do if a product is lost or damaged during shipping?

        A: We purchase shipping insurance for every order to ensure the safety of the products during transportation. If the products are lost or damaged, please contact our customer service team promptly. We will assist you in resolving the issue and provide appropriate compensation.

      View More
      Question has been sent successfully

      Reviews

      • J

        John Tamasi

        Jan 09, 2026

        FEMA Switch DNS16-201
        Really easy to order, thanks!
        Helpful
        Unhelpful
      • K

        Kelley Harris

        Nov 02, 2025

        FEMA Switch DNS16-201
        I really like it.
        Helpful
        Unhelpful
      • C

        Craig Sanford

        Jul 26, 2025

        FEMA Switch DNS16-201
        Genial, tenía la pieza al día siguiente a las 8 de la mañana.
        Helpful
        Unhelpful
      • A

        Anita Holland

        May 29, 2024

        FEMA Switch DNS16-201
        Repair work was completed with ease, thanks.
        Helpful
        Unhelpful
      • A

        Anonymous user

        Nov 25, 2022

        FEMA Switch DNS16-201
        All was ok! No problems whatsoever.
        Helpful
        Unhelpful

      FEMA Switch DNS16-201

      $ 1,373 .08
      Click here to view shipping costs.

      ✔ In Stock (Can ship in 5-7 days)

      Quantity
      MOQ : 1
      Payment Methods
      T/T pay VISA pay mastercard pay Diners Club pay Discover pay JCB pay American Express pay Stripe pay PayPal pay Google pay Apple pay Link pay venmo pay
      • Online Support 24/7

      • 12 Months Warranty for New Products

      • 30 Days Money Back Guarantee

      People who bought this item also viewed

      New In stock for sale, AirTAC Air Cylinder Pneumatic ACQJ25X90-50 Model:Compact Cylinder Pneumatic(Adjustable stroke)

      AirTAC Air Cylinder Pneumatic ACQJ25X90-50 Model:Compact Cylinder Pneumatic(Adjustable stroke)

      US$41.15
      New In stock for sale, Omron Sensor E2EQ-X3D1

      Omron Sensor E2EQ-X3D1

      US$204.13
      New In stock for sale, Siemens Circuit Breaker 5SL6150-7CC

      Siemens Circuit Breaker 5SL6150-7CC

      US$19.53
      New In stock for sale, Siemens Contactor 3TF6933-1DB4

      Siemens Contactor 3TF6933-1DB4

      US$13076.92
      New In stock for sale, SHOWA Overload Pump OLP8S-H-L

      SHOWA Overload Pump OLP8S-H-L

      US$810.00

      Customers frequently viewed

      New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

      IWAYA DENKI Water Pump 25CJT0752

      US$2307.69
      New In stock for sale, Panasonic Servo Motor MHMF022L1V2M

      Panasonic Servo Motor MHMF022L1V2M

      US$653.85
      New In stock for sale, Honeywell Solenoid Valve VE4025B1045

      Honeywell Solenoid Valve VE4025B1045

      US$334.62
      New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

      ROTEN Mechanical Seal 8E5K-22-X

      US$384.62
      New In stock for sale, SANDSUN Overload Pump VA08H-760

      SANDSUN Overload Pump VA08H-760

      US$1568.40
      New In stock for sale, GS Battery 6-QW-60(450)-(55D23L-KR)

      GS Battery 6-QW-60(450)-(55D23L-KR)

      US$646.15
      New In stock for sale, Rechi Compressor 44R273A

      Rechi Compressor 44R273A

      US$341.00
      New In stock for sale, Bosch Rexroth Linear Guideway Runner Block R165381920

      Bosch Rexroth Linear Guideway Runner Block R165381920

      US$107.69
      New In stock for sale, MINDMAN Air Cylinder MCQV2-11-40-200

      MINDMAN Air Cylinder MCQV2-11-40-200

      US$88.46
      New In stock for sale, Mitsubishi Compressor YB645WTG

      Mitsubishi Compressor YB645WTG

      US$549.00
      New In stock for sale, Mitsubishi Servo Drive FCA65S

      Mitsubishi Servo Drive FCA65S

      US$850.41
      New In stock for sale, Copeland Compressor AFE06C4-IAA-901

      Copeland Compressor AFE06C4-IAA-901

      Contact Us
      New In stock for sale, Northman Vane Pump SMVP-12-2-3-V

      Northman Vane Pump SMVP-12-2-3-V

      Contact Us
      New In stock for sale, Sanyo Denki Fan 109P0612S7D01

      Sanyo Denki Fan 109P0612S7D01

      US$13.48
      New In stock for sale, Siemens PLC 6ES7141-3BF00-0XA0

      Siemens PLC 6ES7141-3BF00-0XA0

      US$461.54
      New In stock for sale, AirTAC Air Cylinder Pneumatic PSB16X5Pen size Cylinder Pneumatic(Single acting-push)

      AirTAC Air Cylinder Pneumatic PSB16X5Pen size Cylinder Pneumatic(Single acting-push)

      US$11.92
      New In stock for sale, BOSCH REXROTH Aventics Air Cylinder R480198340

      BOSCH REXROTH Aventics Air Cylinder R480198340

      US$1209.62
      New In stock for sale, AirTAC Air Pneumatic Cylinder MGC50X200 Mini Pneumatic Cylinder(Double acting with cushion)

      AirTAC Air Pneumatic Cylinder MGC50X200 Mini Pneumatic Cylinder(Double acting with cushion)

      US$84.23
      New In stock for sale, Rockwell Allen Bradley AB Circuit Breaker 188-K1B320-N

      Rockwell Allen Bradley AB Circuit Breaker 188-K1B320-N

      Contact Us
      New In stock for sale, SICK Light Curtain C4P-EA12031D00

      SICK Light Curtain C4P-EA12031D00

      US$1470.00

      Recent related posts

      Collection of various types of faults and troubleshooting methods for central air-conditioning!(Ⅰ)

      08/21/2020

      Collection of various types of faults and troubleshooting methods for central air-conditioning!(Ⅰ)

      Collection of various types of faults and troubleshooting methods for central air-conditioning! 1.Failure and maintenance methods of fan coil

      Ten prohibitions on multi-line air conditioning installation

      08/07/2020

      Ten prohibitions on multi-line air conditioning installation

      1. On-site material stacking<br></br>    The materials should be stacked neatly and orderly, and both ends must be sealed to ensure cleanliness. The copper pipe should be placed on a shelf that is ventilated and dry and is above the ground 300mm.

      Methods to prevent failures of industrial chillers

      08/17/2020

      Methods to prevent failures of industrial chillers

      In the process of using the industrial chiller, the prevention of various failures of the industrial chiller can reduce the cost of the company's later maintenance equipment. The stable operation of industrial chillers directly affects the efficiency of e碌7館2䀀締眪湠眷

      Hydronic HVAC System: A Comprehensive Guide

      09/14/2023

      Hydronic HVAC System: A Comprehensive Guide

      Hydronic HVAC systems are becoming increasingly popular as a more efficient and cost-effective way to heat and cool homes and commercial buildings.

      What are the causes of air conditioning trip

      06/20/2020

      What are the causes of air conditioning trip

      What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire.   Here are two formulas involved:   ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required.   ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current.    So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit.    Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle.    2. Leakage   During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip.   Why does the electric leakage cause the MCB to trip? There are two situations.    ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close.   ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open.   How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter.    ① Measure the voltage at the input and output to see if there is a significant change in voltage drop.   ②Measure whether the output current exceeds the standard.    So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.

      Ways to improve the service life of control valves

      08/16/2020

      Ways to improve the service life of control valves

      The control valve is not like a manual valve. After it is installed, it is rarely managed and maintained. It must be maintained frequently to ensure normal operation and long service life. Below we introduce eight ways to extend the service life of the control valve.

      Too high or too low oil pressure of industrial chillers affects normal operation

      08/17/2020

      Too high or too low oil pressure of industrial chillers affects normal operation

      When using industrial chillers, regular inspection and maintenance work is essential. In the absence of basic maintenance and regular inspections, many industrial chillers are prone to different failures.

      Troubleshooting Guide: Convection Oven Fan Not Spinning

      02/06/2024

      Troubleshooting Guide: Convection Oven Fan Not Spinning

      The convection oven, with its innovative fan system, has revolutionized the way we cook, offering even heat distribution and faster cooking times.

      Classification of solenoid valves

      09/06/2020

      Classification of solenoid valves

      Direct acting solenoid valve    Introduction:   There are two types: normally closed and normally open. The normally closed type is closed when the power is cut off.

      Gas Shut-Off Solenoid Valve: Basics, Working Principles and Applications

      07/22/2024

      Gas Shut-Off Solenoid Valve: Basics, Working Principles and Applications

      Gas shut-off solenoid valves, also known as gas safety shut off solenoid valves and gas emergency shut off solenoid valves, are emergency shutoff devices for gas pipelines.

      • Welcome to O&Kmarts

        Is there anything we can help?

        Email us
      • Feedback

      Join in

      Join in to enjoy exclusive discounts and give you greater discounts

      See More About O&Kmarts Member
      Sign up now

      Common Problem

      Payment Methods
      Shipping Guide
      Sales and Refund Policy
      FAQs

      About O&Kmarts

      About Us
      Membership

      Website Terms

      Privacy Policy
      Terms Of Use
      Bidding Agreement
      Review Rules

      Customer Service

      support01@okmarts.com
      service@okmarts.com
      hydraulic@okmarts.com
      +86-28-84166335
      GMT+08:00 Mon-Fri, 9:00 AM-7:00 PM
      Customer Feedback

      POPULAR PRODUCTS :

      Omron Switch SCHUNK Switch ERSCE Switch NKK Switch CHANTO Switch KROM Switch Trane Switch DANFOSS Switch 112-63 E100-01-S5I  T1R256-02Z ZLDXC03CH DL3AG-6K2 25CJT0752 MHMF022L1V2M VE4025B1045 8E5K-22-X VA08H-760 750el 128d3 ad1212hb a71gl ad1212hb y53 APISTEK GA51S2U BFB0712H Bifold FP06P-S1-04-32-NU-V-77A9-24D-ML-30-K85 CAJ4492Y Carrier EA03XC385 Chelic SV-8103-24VDC-K CKD 4KA249-06-B-AC100V Copeland BRG2-0900-TFD-501 Copeland RS97C1E-CAV-101 fuji src3631 02 LG MB98NAEM mdr 40 12 Mitsubishi JH527YEB Parker Sporlan 111270 rsp 320 5 sgdh 30ae Unitta Belt

      Disclaimer: All brand names, model or type numbers or marks listed on the website are owned by their respective manufacturers. These terms are used for identification purposes only and are not intended to indicate affiliation with OEM companies. Product pictures shown on the website are for illustrative purposes only and the actual item may vary in design, specification, etc. Confirm at the time of purchase if you are unsure.

      © eCommerce. 2017-2025. All Rights Reserved
      © eCommerce. 2017-2025. All Rights Reserved
      Press and drag the mouse to start taking a screenshot