Piston diameter: 20 mm
Type code: ADN
Based on norm: ISO 21287
Cushioning: Elastic cushioning rings/pads at both ends: Self-adjusting pneumatic end-position cushioning
Mounting position: Any
Design: Profile barrel: Piston: Piston rod
Position sensing: For proximity sensor
Variants: Through piston rod: Continuous, hollow piston rod: Piston rod at one end: Special thread on piston rod: With anti-twist protection: Explosion protection certification (ATEX): Low friction: High corrosion protection: Heat-resistant seals max. 120Celsius Degree: Increased service life: Extended piston rod: Laser etched rating plate: Constant, slow movement: Extended external thread piston rod: Dust protection: Temperature range -40 to 80 Celsius Degree
Operating pressure: 0.6 bar - 10 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: c T4
ATEX category for dust: II 2D
Type of (ignition) protection for dust: c 120Celsius Degree
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 2 (ATEX): Zone 1 (ATEX): Zone 21 (ATEX): Zone 22 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Theoretical force at 6 bar, retracting: 141 N
Theoretical force at 6 bar, advancing: 141 N - 188 N
Moving mass at 0 mm stroke: 30 g
Additional weight per 10 mm stroke: 21 g
Basic weight with 0 mm stroke: 131 g
Additional moving mass per 10 mm stroke: 6 g
Type of mounting: Optionally:: With internal thread: With through-hole: With accessories
Pneumatic connection: M5
Note on materials: RoHS-compliant
Cover material: Anodized: Aluminum
Piston rod material: High-alloy steel
Material of cylinder barrel: Smooth anodized: Wrought aluminum alloy
Festo Air Cylinder ADN-20-80-I-P-A
People who bought this item also viewed
MINDMAN Air Cylinder MCQV2-11-40-200
AirTAC Air Cylinder SC40X70
CKD Air Cylinder SCPG2-M-00-10-30
Festo Air Cylinder SLT-16-150-A-CC-B
Festo Air Cylinder ADN-16-40-I-P-A
Festo Air Cylinder DSNU-10-40-P-A
Festo Air Cylinder ADVU-32-10-A-P-A-S2
Festo Air Cylinder ADVU-100-20-P-A
Festo Air Cylinder DSNU-12-30-P-A
MINDMAN Air Cylinder MCMA-11-25-125
Festo Air Cylinder DNG-63-300-PPV-A
HENGSTLER Encoder AC36/1213ER.41SGA
SIEMENS Actuator GMA126.1E
Bellofram Proportional Valve 969-753-000
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
FOTEK Sensor CDT-60MX-V-M12
Recent related posts
-
12/19/2021
TECO Servo JSDEP Works for Food Placement Machine
It evenly arranges the formed food, such as moon cakes, bread, chocolate and other foods with solid shapes into the trays of standard specifications according to the set number of rows and columns
-
07/02/2022
How To Repair a Pool Spring Flapper Check Valve
With time, the spring or flapper seal in a pool Spring Flapper Check Valve will deteriorate to the point where the Check Valve will begin to leak and water will start to flow backwards through the pipes when the pump is off.
-
06/13/2020
Twin screw compressor
Twin screw compressor
-
12/26/2023
Troubleshooting the "Air Conditioner Fan Not Spinning But Hums" Issue
When your air conditioner's fan refuses to spin but emits a distinctive hum, it can be a frustrating and perplexing situation.
-
01/09/2021
Be sure to understand these before installing a new fan
The most troublesome thing: the new fan requires indoor and outdoor air exchange, which requires opening holes on the wall or glass. The diameter of the holes in the market is basically concentrated on 150mm\120mm\110mm\100mm.
-
05/04/2023
What is an HVAC System?
There are many systems and components in a home or building that we take for granted, such as roofs, plumbing, and electricity. HVAC is the main system that probably will be most underrated: a massive heating and cooling system driven by a miniature thermostat.
-
02/28/2022
Introduction to the Principle, Types and Advantages of Gas Sensors
The gas sensor is used to detect specific gases in a certain area and continuously measure the concentration of gases as well.
-
06/13/2020
How to solve the problems encountered during the operation of 120KW cold air-cooled compressor
The 120KW cold capacity air-cooled compressor mainly has three related systems: refrigerant circulation system, water circulation system and automatic electrical control system.
-
08/12/2020
Have you figured out the "enthalpy" and "entropy" of the refrigeration system?
1. Enthalpy<br></br> It is a kind of energy, used to indicate the thermal state parameter of the state of the refrigerant, it represents the size of the total energy of the refrigerant; namely:
-
06/13/2020
Is it necessary to install the fresh air system recommended during decoration Where are the people who have been eating ash for many years but are secretly happy this year
Is it necessary to install the fresh air system recommended during decoration Where are the people who have been eating ash for many years but are secretly happy this year Is it necessary for ordinary families to install fresh air system?