Piston diameter: 10 mm
Type code: ADVC
Cushioning: Elastic cushioning rings/pads at both ends
Mounting position: Any
Mode of operation: Double-acting
Design: Piston rod: Piston
Position sensing: For proximity sensor
Symbol: 00991217
Operating pressure: 1 bar - 8 bar
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC): 1 - Low corrosion stress
Ambient temperature: -20 to 80 Celsius Degree
Theoretical force at 6 bar, retracting: 40 N
Theoretical force at 6 bar, advancing: 47 N
Moving mass: 3.7 g
Product weight: 45 g
Type of mounting: Optionally:: With through-hole: With accessories
Pneumatic connection: M5
Note on materials: Free of copper and PTFE
Cover material: Anodized: Wrought aluminum alloy
Seals material: TPE-U(PU): NBR
Housing material: Anodized: Wrought aluminum alloy
Piston rod material: High-alloy steel
Festo Air Cylinder ADVC-10-10-A-P-A
People who bought this item also viewed
Festo Air Cylinder DGP-32-600-PPV-A-B-KH-GK
CAMOZZI Air Cylinder 61M2P063A0305
Festo Air Cylinder ADNGF-12-60-P-A
Festo Air Cylinder DGSL-12-30-Y3A
Festo Air Cylinder DSM-32-270-P-A-B
Festo Air Cylinder DNC-63-200-PPV-A
TPC Air Cylinder ARDB63-1000-XRO
Festo Air Cylinder DZH-40-160-PPV-A
MINDMAN Air Cylinder MCJA-11-32-25M
CHANTO Air Cylinder ASR150X300
SMC Solenoid Valve VQ7-8-FIG-D-3Z
SIEMENS Actuator GLB332.1E
SMC Proportional Valve ITV3030-313N5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Dwyer Transmitter 626-07-GH-P1-E1-S1
WURTH Switch 428521320810
AirTAC Air Cylinder MAC32X125SCA
Contrinex Sensor BD10-S1-Q25
CPC Linear Guideway HRC45FL
KONOR Compressor GQR70AA
Recent related posts
-
06/14/2020
The central air conditioner can be used! Must use outdoor clean fresh air
The central air conditioner can be used! Must use outdoor clean fresh air There have been no newly diagnosed and asymptomatic infections in Guangdong for many days, and the epidemic prevention and control has entered a new normal stage
-
09/22/2020
Compressed air dewatering, oil removal and dust removal multifunctional filter
Compressed air degreasing, water removal and dust removal filter (purification equipment) Sometimes, connecting a piece of equipment to a compressed air supply station cannot solve the quality of compressed air.
-
08/20/2020
How to calculate air conditioner power-what is air conditioner power
The cooling power of the air conditioner refers to the total power consumed within the rated time when the air conditioner is in cooling operation, and the unit is W. It should be noted that the cooling power and cooling capacity are different.
-
07/21/2020
How to protect the refrigeration compressor, you must master the following knowledge!
When the compressor is running, some abnormal conditions may occur, such as: exhaust pressure is too high, suction pressure is too low, oil pressure is insufficient, motor is overheated, excess liquid enters the cylinder, etc. In the event of an abnormal situation, the compressor will be damaged if there is no protective measure.
-
06/26/2023
Why is My Fridge Not Cooling & How to Fix
A refrigerator is one of the most important appliances in any home. It keeps your food fresh and prevents spoilage. However, if your fridge is not cooling, it can be a cause for concern.
-
06/28/2020
Trouble analysis and elimination of semi-hermetic compressor motor
Trouble analysis and elimination of semi-hermetic compressor motor Abstract:Semi—hermetic compressor often be used in the water—cooling unit of air conditioning system,and it’S motor which work in rather high temperature and pressure condition,even work with refrigerator and oil, has a poor working condition.
-
01/12/2021
To be honest for 3 years Which is more cost-effective, ordinary air conditioner or central air conditioner Too many families think wrong
To be honest for 3 years Which is more cost-effective, ordinary air conditioner or central air conditioner Too many families think wrong More than one person came around and asked me when I was decorating, which one is more cost-effective to install ordi 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱
-
10/29/2021
Advantages of VFD for HVAC System
One of the most successful energy management tools ever used in HVAC (Heating, Ventilating and Air Conditioning) systems of buildings is the Variable Frequency Drive (VFD).
-
06/14/2020
Analysis and solution of the three reasons for the high temperature of the exhaust of the compressor dryer
Analysis and solution of the three reasons for the high temperature of the exhaust of the compressor dryer
-
08/17/2021
What to do if Your Compressor is in Reverse Rotation
As we know, the operation of the internal compression structure of the refrigeration compressor has a fixed direction.