Stroke: 2 mm - 2000 mm
Piston diameter: 32 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: None: For proximity sensor
Variants: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Continuous, hollow piston rod: Extended external thread piston rod: With anti-twist protection: Piston rod at one end: Through piston rod: Increased service life: With rear end-position locking: Temperature range -40 to 80 Celsius Degree: Extended piston rod: Clamping unit on the piston rod: With front end-position locking: Low friction: With end-position locking at both ends: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: High corrosion protection: Internal thread on piston rod: Dust protection: Piston rod with external hexagon: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: Constant, slow movement: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Special thread on piston rod
Protection against torsion/guide: Square piston rod
Operating pressure: 0.2 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 22 (ATEX): Zone 1 (ATEX): Zone 2 (ATEX): Zone 21 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress: 3 - High corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.1 J
Max. torque for protection against rotation: 0.8 Nm
Theoretical force at 6 bar, retracting: 415 N
Theoretical force at 6 bar, advancing: 415 N - 483 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G1/8
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-32-320-PPV-KP
There is no price at present, you can Request a Quote
People who bought this item also viewed
CHANTO Air Cylinder JSR32X10B
Festo Air Cylinder SLG-18-200-YSR-A
Festo Air Cylinder DGC-25-625-KF-PPV-A
CHANTO Air Cylinder DXSL20X15
Festo Air Cylinder DSNU-32-60-PPV-A
Festo Air Cylinder DNC-63-300-PPV-A-KP
Festo Air Cylinder SLS-10-30-P-A
Festo Air Cylinder AEVULQ-20-25-P-A
MINDMAN Air Cylinder MCJT-12-12-10
Festo Air Cylinder ESNU-12-25-P-A
Festo Air Cylinder ADN-20-60-I-P-A
SIEMENS Actuator GDB132.1E
SMC Proportional Valve ITV1030-33F2N3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Delta Fan ASB0812HH
WINMOST Solenoid Valve WD-G03-B7A-A1
Yaskawa Servo Motor SGMAS-08A2A21-Y1
GRACO Diaphragm Pump 223500
TCL Air Conditioner KFRd-35GW-DBp-XJ11+B1
Recent related posts
-
02/23/2021
The reason why the air conditioner is not cooling
Occasionally encounter the problem that the air conditioner does not cool in life. Don't worry at this time. The reason for the air conditioner not cooling is not very complicated. After understanding the reason for the air conditioner not cooling, you can solve the problem by taking the right medicine.
-
03/23/2023
Common Faults, Reasons of Faults, and Solutions of Vacuum Pump
common faults like falling vacuum degree, abnormal operation, even being jammed, large noises and oil leakage resulting from not well-sealed pump body appears in the operation
-
06/14/2020
How to solve the problems encountered during the operation of 120KW cold air-cooled compressor
How to solve the problems encountered during the operation of 120KW cold air-cooled compressor
-
08/19/2020
What should I do if the freezer trips
Tripping when the freezer starts is a problem that many users may encounter when using the freezer for the first time. Domestic refrigerators are widely used. Although domestic refrigerators have high performance,
-
06/14/2020
Danfoss cocuses on providing energy efficient, sustainable and smart refrigeration compressors for a varied range of commercial applications such as cold rooms
-
08/20/2021
Things You Need to Know about Refrigerator Compressor Hot
A lot of people are worried about whether the compressor overheating is due to refrigerator quality problems.
-
08/20/2020
Small low-temperature cold storage the unique secret to extend the storage time of fruits and vegetables by 10 times
With the requirements of industry density and specialization, the production areas of fruits and vegetables are mainly concentrated in several places. In order to meet the needs of the national market and even the global market
-
08/05/2020
How to solve the common old problems in the operation of chillers
In the pharmaceutical, food, chemical and other industries, process water cooling is required. The chiller has become a must-choice equipment for many industries.
-
07/23/2021
How to Maintain Your Screw Air Compressor?
The screw air compressor adopts a single power connection and compressed air connection, and a built-in cooling system, which greatly simplifies the installation process.
-
08/03/2020
Can a low-power air conditioner use a five-hole socket
Five-hole socket and three-hole socket<br></br> The five-hole socket we usually talk about refers to the wall socket with a rated power of 10A; the three-hole socket refers to the wall socket with a rated power of 16A.