There is no price at present, you can Request a Quote
Stroke: 1 mm - 200 mm
Piston diameter: 12 mm
Type code: DSNU
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Conforms to standard: CETOP RP 52 P: ISO 6432
Design: Piston: Piston rod: Cylinder barrel
Position sensing: For proximity sensor
Variants: Piston rod at one end: High corrosion protection: Clamping unit on the piston rod: Low friction: Constant, slow movement: Axial supply port: With anti-twist protection: Extended piston rod: Piston rod with external thread shortened at one end: Transverse supply port: Through piston rod: Extended external thread piston rod: With direct mounting: Heat-resistant seals max. 120Celsius Degree
Protection against torsion/guide: Square piston rod
Operating pressure: 1.5 bar - 10 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 22 (ATEX): Zone 1 (ATEX): Zone 21 (ATEX): Zone 2 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -20 to 120 Celsius Degree
Impact energy in the end positions: 0.07 J
Theoretical force at 6 bar, advancing: 51 N - 68 N
Type of mounting: With accessories
Pneumatic connection: M5
Note on materials: RoHS-compliant
Cover material: Wrought aluminum alloy
Seals material: TPE-U(PU): NBR
Piston rod material: High-alloy stainless steel
Material of cylinder barrel: High-alloy stainless steel
Festo Air Cylinder DSNU-12-125-PPV-A-S2
There is no price at present, you can Request a Quote
People who bought this item also viewed
CKD Air Cylinder STSB-4010
CKD Air Cylinder SCPG2-M-00-10-30
CAMOZZI Air Cylinder 61M2P063A0305
Festo Air Cylinder DSM-12-270-P-FW
Festo Air Cylinder ADVU-20-10-P-A
Festo Air Cylinder DSEU-63-200-P-A
Festo Air Cylinder DFM-16-80-P-A-GF
KOGANEI Air Cylinder DA32X75-A
Festo Air Cylinder DGP-40-200-PPV-A-B
Festo Air Cylinder DGSL-20-200-Y3A
Festo Air Cylinder DZH-32-75-PPV-A
MTL Encoder MEH-60-500P
UNIVER Solenoid Valve BE-3720
Belimo Actuator LMU24-SR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Fuji Belt SPA-2332
YUASA Battery NPL170-12
KOGANEI Air Cylinder XDAQ20X50
Recent related posts
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
03/05/2021
Precautions for use and installation
Ambient temperature of servo driver. 1) Operating temperature: - 10 ℃ ~ + 40 ℃; (2) storage temperature: - 25 ℃ ~ + 65 ℃; (3) ambient humidity: 5% ~ 90%, no condensation; (4) vibration / shock: vibration is 0.5g (4.9M / S2), shock is 2G (19.6m / S2).
-
09/10/2020
Analysis on the New Trend of Chinese Inverter Compressor Technology Development
In 1978, Japanese air-conditioning companies put forward the concept of inverter air conditioners. Because inverter air conditioners have many advantages, they soon entered the families of developed countries.
-
12/26/2022
What is a Programmable Logic Controller?
The programmable logic controller (PLC) is a digital operation electronic system specially designed for application in industrial environment.
-
01/09/2021
Do you know what is a central dust removal system ?
How to create a cleaner environment more efficiently, along with people's awareness and awareness of cleanliness, also mentioned in front of people. Generally, various cleaning agents, cleaning tools and cleaning equipment in the traditional sense have va 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V
-
08/02/2020
New refrigerant R450A is used for performance study of ejector refrigeration cycle
The new refrigerant R450A is a substitute for R134a, which is environmentally friendly and reliable. There are still few studies on it.
-
06/22/2020
Working principle of steam compressor_steam compressor application
Working principle of steam compressor_steam compressor application Working principle of steam compressor After the steam is filtered by the filter, clean steam then enters the host cavity through the intake valve, and the volume of the cavity changes from large to small to compress the steam. The volume of the cavity is changed by the rotor rotating under the drive of the motor. <img src="{{media url="Working_principle_of_steam_compressor_steam_compressor_application.jpg"}}" alt="" />
-
06/17/2020
The role of refrigerator compressors
The role of refrigerator compressors The role of refrigerator compressor The compressor is the power of the refrigerator, which is equivalent to the heart of the refrigerator, compresses the refrigerant, increases the pressure and temperature of the r 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧
-
06/14/2020
Note! Seven mistakes in the maintenance of refrigeration equipment
Many refrigeration maintenance masters, seeing the internal leakage of the refrigerator, will directly add the condenser net without pressure, and it will not leak again for a long time. It turns out that it is the evaporator of the refrigerator compartme 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ښ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
04/25/2022
How to Install A Surge Protection Device?