Fuji PLC NWOP32R-3
People who bought this item also viewed
Omron PLC CJ1W-NC271
Mitsubishi PLC FX5UJ-40MR-ES
SIEMENS Servo Motor 1FT6102-4AC71-3AH1
Sanyo Denki Servo Drive 65AA008VXR01
HENGSTLER Encoder RI76TD/1000ED.1A25KF
Panasonic Extension Module AFPX-EFP0
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CKD Air Cylinder SSD2-KL-16-10-N-W1
AirTAC Air Cylinder SGCD250X200S
ADDA Fan AD0512UB-TBB
SMC Solenoid Valve VX3324-02-5G1-B
Festo Air Cylinder AEVULQ-100-30-P-A
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/08/2021
Four technical advantages of Mitsubishi Electric compressor
Four technical advantages of Mitsubishi Electric compressor Those who get the Central Plains get the world, those who get the compressor get the comfort, energy saving, mute and long service life of the central air conditioner. Mitsubishi Electric is a 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ъ 識
-
06/14/2020
Popularly speaking, what is the difference between heating 24℃ and cooling 24℃
Popularly speaking, what is the difference between heating 24℃ and cooling 24℃ Everyday use of air conditioners must have this experience: in the summer, the air conditioner is used for cooling. Setting the temperature to 24°C makes the room very cool, a 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ
-
06/14/2020
The difference between single and twin screw compressors is reflected in the following 6 aspects
The difference between single and twin screw compressors is reflected in the following 6 aspects
-
06/14/2020
Advantages of cascade cryogenic refrigeration system industrial chillers
Advantages of cascade cryogenic refrigeration system industrial chillers The cascade refrigeration system is a low-temperature refrigeration system that uses more than two refrigerants and combines them with a heat exchanger (condensation evaporator) in ﰸ2 䀀 ᅵ皥
-
08/17/2021
What to do if Your Compressor is in Reverse Rotation
As we know, the operation of the internal compression structure of the refrigeration compressor has a fixed direction.
-
12/20/2023
Troubleshooting a Split AC Not Cooling But Fan is Running (12 Possible Reasons)
A split air conditioner, known for its efficiency and comfort, can be a savior during the scorching summer months.
-
12/18/2021
Basics of Encoder and Orthogonal Coding
Encoder is a kind of electromechanical equipment, which can be used to measure the movement of machinery or the target position of machinery.
-
09/21/2020
Product development of CFT-303.8 centrifugal chlorine compressor
Hangzhou Hangyang Compressor Co., Ltd. is one of the core enterprises of Hangyang Group. Its leading product is the development and production of various gas-medium compressor products for empty distribution sets and chemical processes (the variety and specifications have reached more than 110 Species);
-
09/06/2023
What is an Inverter Heat Pump: Understanding the Technology and Benefits
An inverter heat pump is a type of HVAC system that uses advanced technology to provide efficient heating and cooling for residential and commercial spaces. Unlike traditional HVAC systems, which operate at a fixed speed, inverter heat pumps can vary their output to match the exact requirements of your space.