Real-time Clock ± 1 minute per month 0° to 50°C (32° to 122°F)
Battery 2/3 AA, 3.6 Volt lithium, factory-replaceable
Battery Life (Typical Use) 5 years with 1 minute or greater logging interval
Memory (Non-volatile) 64K bytes memory (approx. 21,700 pressure and temperature samples)
Operation Range -20° to 50°C (-4° to 122°F)
Accuracy ±0.44°C from 0° to 50°C (±0.79°F from 32° to 122°F), see Plot A in manual
Resolution 0.10°C at 25°C (0.18°F at 77°F), see Plot A in manual
Response Time (90%) 5 minutes in water (typical)
Stability (Drift) 0.1°C (0.18°F) per year
Raw Pressure Accuracy** ±0.3% FS, 0.62 kPa (0.09 psi) maximum error
Resolution <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
HOBO Level Meter U20L-02
People who bought this item also viewed
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
Kacon Relay 730-1QR 24VDC
TTO Oil Seal TB 17*28*7
Festo Solenoid Coil MSG-24DC
TRIAD Transformer F-96U
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Banner Sensor LS2LP30-900Q88
BOURNS Encoder ENC1J-D16-L00128L
Schneider Sensor XUM5ANANL2
Sanyo Denki Fan 9GL1224H103
Mitsubishi Servo Motor HF453S-A48
Recent related posts
-
08/13/2020
How to apply the functions of cooling, heating, humidification, and dehumidification of computer room air conditioning
1. Uninterrupted operation and year-round refrigeration<br></br> The heat dissipation of the equipment in the computer room is a steady-state heat source, and it operates continuously throughout the year. This requires an uninterrupted air-conditioning gPﰨ2 䀀 湠癐
-
03/03/2021
Type selection calculation of servo motor
Confirmation of speed and encoder resolution. Conversion of load torque on motor shaft and calculation of acceleration and deceleration torque.
-
07/31/2020
What kind of equipment is suitable for high and low pressure refrigerant charging method
There are generally two types of refrigerant charging methods: low-pressure charging and high-pressure charging. The advantage of the low pressure charging method is that it is easier to control the amount of refrigerant charged,
-
06/14/2020
Carry out special inspection of centralized air conditioning and ventilation systems
Carry out special inspection of centralized air conditioning and ventilation systems Recently, the Keqiao District Sanitary Supervision Department has carried out special inspections
-
06/27/2020
Compressor installation
Chapter 1 General Provisions Article 1 This chapter is applicable to the installation of reciprocating piston type, screw type, vane type and membrane type positive displacement compressors.
-
09/23/2022
Common Faults and Troubleshooting of Gear Pumps
Gear oil pump can be used as oil transfer pump, lubricating pump, booster pump, and fuel pump, suitable for hydraulic systems of machine tools
-
11/20/2023
Difference in 2 Pin, 3 Pin and 4 Pin Computer Fans: Which is better?
If a computer does not have a radiator, its internal temperature will be infinitely high, and eventually the hardware will be burned directly. Whether it is for the CPU, graphics card, chassis, or power supply, heat dissipation is required.
-
12/19/2022
The Ultimate Guide to Memory Card Selection
To select the proper memory card, storage, transfer speed, speed class, and price are all factors to consider. Here is a complete guide to determine these factors.
-
07/28/2020
Overview of refrigeration compressor classification
The compressor is the core equipment in the refrigeration system. Only by converting electrical energy into mechanical work and compressing low-temperature and low-pressure gaseous refrigerant into high-temperature and high-pressure gas can the refrigeration cycle be ensured
-
01/05/2021
Real Gas Model for an Electric Swashplate Refrigeration Compressor
Real Gas Model for an Electric Swashplate Refrigeration Compressor Author links open overlay panelMohammadArqam1Dzung VietDao1AmirJahangiri2MarkMitchell2PeterWoodfield1 1 School of Engineering and Built Environment, Griffith University, Australia 2 U 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦