RESOLUTION(PPR):1024
OUTPUT SIGNALS:AB0/AB0 cable output
SUPPLY VOLTAGE:+5V/+30V(H output circuit)
SHAFT DIAMETER :15mm
Lika Encoder C58A-H-1024ZCU415
People who bought this item also viewed
Lika Encoder IT65-H-1024ZCP4ER
Lika Encoder C80-H-2048ZCU430L2
Lika Encoder C80-H-1024ZCU430L2
Lika Encoder C50-Y-360ZNF26L3
MTL Encoder MEH-30-3600PE
HENGSTLER Encoder RI58-D/5000AF.47RB
Yaskawa Servo Motor SGMAH-01AAA41D-OY
Sanyo Denki Servo Drive QS1L01AA045A3PAR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Contactor 3RT2025-4XJ40-0LA2
AirTAC Air Cylinder SC250X800-S
SUNON Fan PE60252B3-000C-G99
Recent related posts
-
06/16/2022
What is A VFD?
A Variable Frequency Drive (VFD) is a type of motor controller that drives an electric motor by varying the frequency and voltage supplied to the electric motor.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
03/10/2021
The main circuit fuse fusing is a common fault of SCR servo driver. The causes of fuse fusing are as follows
The "phase sequence" of power incoming line is incorrect. Due to the synchronization problem between the trigger pulse and the main circuit of SCR servo driver, there are strict requirements on the "phase sequence" of the input power supply. If the "phase sequence" is not correct, connecting the power supply may immediately cause the fuse of the main circuit of the driver to blow.
-
08/15/2020
What should I do if the refrigeration performance of industrial refrigerators declines
When many enterprise users use industrial refrigerators, due to the lack of knowledge about the use and maintenance of equipment, industrial refrigerators are prone to various failures
-
08/07/2020
Common physical and chemical methods for removing scale in condensers in chillers
The water chiller is prone to scale formation in the condenser pipe after long-term use. If it is not treated in time, these scales will affect the heat exchange effect and cause the condensing temperature of the unit to increase
-
07/06/2020
Air Compressor Market product type, technology, lubrication, application, key Players and region Analysis
The dramatic spread of COVID-19 has created a marginal impact on the global air compressor market. The sustainability of the air compressor market is mainly attributed to the significantly increasing demand from various industries such as oil & gas, healthcare, chemical manufacturing, and many others. In addition, it is expected that the demand for the air compressor will be ultimately restored after the outbreak of COVID-19.
-
06/14/2020
One of the directions of scroll compressor's attack deep dive into the low-temperature market
One of the directions of scroll compressor's attack deep dive into the low-temperature market In Panasonic's view, in the field of air conditioning
-
01/20/2023
Choose the Right Solenoid Valve
Solenoid valves are industrial equipment controlled by solenoids. It is the basic element of automation used to control fluids.
-
08/06/2020
How to distinguish the authenticity of the compressor of the antifreeze chiller
The familiar "pump" is a mechanical device that can increase potential energy. For example, a water pump mainly pumps water from a low position to a high position.
-
12/01/2021
With COVID-19 Outbreak, Will Sensors be Next Hot Market in Medical Industry?
Last year was a very hard year with the COVID-19 epidemic, everyone saw the important role of the medical device industry.