Littelfuse Fuse 153.5395.6501
People who bought this item also viewed
Siemens Circuit Breaker 5SY6340-8CC
Schneider Contactor LC1E160Q6N
CITEL Surge Protection Device DS98-400
ABB Relay K6-31Z 24V
Yageo Resistor RC0805FR-0710RL
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Recent related posts
-
08/07/2020
What should I do if the refrigeration compressor returns oil
During the operation of the system, the lubricating oil is discharged from the compressor along with the refrigerant, and returns to the compressor after the cycle.
-
07/25/2020
The 9 types of compressor failure and hazard analysis are all in it! ! !
Start with liquid is a problem that easily occurs during shutdown. In the shutdown state, the refrigerant will migrate from the system back to the compressor and be deposited in the lubricating oil.
-
08/20/2020
How to prevent high temperature alarm of industrial chiller in summer
In the high temperature and hot summer, the frequency of use of industrial chillers is the highest in a year, and summer is also the season when industrial chillers have the most frequent high temperature alarms.
-
09/10/2020
Afternoon tea problems often exist in air conditioning design
The author of okmarts.com came into contact with the HVAC engineering design of some design institutes, and compared the "Code for Design of Heating, Ventilation and Air Conditioning"
-
07/16/2020
Compressor failure and elimination
The compressor is the heart of the refrigeration system. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and discharges high-temperature and high-pressure refrigerant liquid to the exhaust pipe to provide power for the refrigeration cycle.
-
06/14/2020
Ammonia refrigeration equipment has leaked, which is the safest way to deal with it!
Ammonia refrigeration equipment has leaked, which is the safest way to deal with it! 1. The danger of ammonia refrigeration system in advance According to the statistical analysis of the actual operation of the refrigeration system, the safety risk ma 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢
-
06/14/2020
Today, a user who came to repair a display cabinet said that the compressor of the freezer sometimes works and sometimes does not work
Today, a user who came to repair a display cabinet said that the compressor of the freezer sometimes works and sometimes does not work.
-
08/02/2020
Characteristics of R12, R22, R407C refrigerants in cold storage
don’t know if you still remember that okmarts.com wrote "How to Choose Refrigerant for Cold Storage Design" some time ago. Today okmarts.com will introduce several different cold storage refrigerants in detail, namely R12, R22, R407C
-
06/24/2020
What to do if Haier refrigerator doesn't cool
In the process of using home appliances, there will be some situations. I believe many people have encountered that the refrigerator at home is not cooling. What will you do when you encounter this situation? Let’s take a look at Haier with the editor. What to do if the refrigerator is not cooling, for your reference.
-
05/14/2022
What Are The Input And Output Module (I / O) of PLC?
PLC I/O is the part of the PLC that connects the brain of the PLC, the CPU, to the outside world, the machines.