MICREL IC Integrated Circuit Chip MIC2003-0.5YML-TR
People who bought this item also viewed
Panasonic PLC FPG-C28P2H
BLKE Micro SD Card BLKE 64G class10
Beckhoff Module KL9505
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MINDMAN Air Cylinder MCQA-11-100-720M
ARK Air Cylinder KCDQ2A100-15
Danfoss Solenoid Valve Coil BE380AS
ARK Air Cylinder KCP95SDB50-500
Sanyo Denki Fan 109P6612H2026
Recent related posts
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/21/2020
Types of steam compressors_selection of steam compressors
Types of steam compressors_selection of steam compressors Types of steam compressors<img src="{{media url="Types_of_steam_compressors_selection_of_steam_compressors.jpg"}}" alt="" /> 1. Single-stage high-speed centrifugal blower This type of steam compressor is a relatively common steam compressor on the market. It can have a large air volume and pressure and can meet the needs of many working conditions. The single-stage high-speed centrifugal blower is designed with a ternary flow theory, and the whole structure of the fan is compact , And the technology is relatively mature. 2. Roots type steam compressor
-
06/13/2020
What are the causes of frost in refrigeration compressors
1. The opening of the thermal expansion valve is too large, or the installation of the temperature sensor is incorrect and the fixing is not firm or loose. The main reason is that the temperature sensor may feel the temperature too high in this case, resu 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž
-
10/22/2021
List of Problems and Solutions for Centrifugal Air Compressor
As a speed type air compressor, centrifugal compressor can generate air flow moving in radial direction.
-
01/10/2024
Common Faults of Cold Storage (with a List of Fault Repair Methods)
Cold storage is an indispensable and important facility in many industries. They play a key role in storing and preserving various products. However, even with the most sophisticated systems, cold storage can suffer from various failures.
-
01/14/2021
Causes and solutions of air-conditioning leakage
Some air conditioners will leak when used for a long time, and some new air conditioners have no problem in debugging, but after a few days of use, there will be water leaks, so what is the reason for air conditioning leaks? Today we will talk about the r 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ
-
07/27/2020
What is the principle of air conditioning refrigeration system? What is the heating principle of the air conditioner?
When we use the air conditioner, the commonly used function should be the cooling function, because the cooling function can bring us a more comfortable and cool environment in summer,
-
06/13/2020
The working principle of refrigeration compressors_The main performance parameters of refrigeration compressors
Working principle of refrigeration compressor
-
03/10/2023
Advantages of Motor Soft Starter
Motor is widely applied in industry and daily life, thus people attach more importance to the starting method of motor. Generally, motor soft starter should be used when motor working power exceeds 30 kilowatts
-
06/13/2020
How to solve the problems encountered during the operation of 120KW cold air-cooled compressor
The 120KW cold capacity air-cooled compressor mainly has three related systems: refrigerant circulation system, water circulation system and automatic electrical control system.