Series | MCMI Series |
Acting type | Double acting / Male thread |
Tube I.D.(mm) | 25 |
Stroke (mm) | 25 |
CUSHION TYPE | Cushion pad (Unadjustable) |
END COVER TYPE | Standard type |
PORT POSITION | Standard type |
Port size | G1/8 |
Medium: Air
Max. operating pressure: 0.7 MPa
Min. operating pressure: 0.1-0.08 MPa Proof pressure: 1 MPa
Ambient temperature: -5 - 60 degree celsius (No freezing)
Lubricator: Not required
Available speed range: 50-500 mm/sec
Sensor switch: RCM We can also provide the following models
MCJQ-15-16-100M-F-G
MCMB-27-40-250-E-G
MCSS-20L-100-B-NPT
MCMB-13-25-25-A-N-G
MCSS-25L-75-BT-NPT
MCJQ-22-32-30M-F-G
MCSS-12L-30-AS-X12-G
MCGS-03-32-50-NPT
MCMI-21-40-500-F
MCMI-11-16-100-F
MCCG-28-40-800M-20-NPT
MCGS-23-25-125-G
MCMI-13-10-40-R
MCSS-8L-10-BS-X12-G
MCJQ-23-20-125M-F-NPT
MCSS-6L-50-AS-X11
MCJQ-24-80-25M
MCJQ-23-40-25M-F-NPT
MCMI-21-40-75-H
MCMB-27-40-250-A-E-G
For more information,please contact us freely
MINDMAN Air Cylinder MCMI-11-25-25
People who bought this item also viewed
CHANTO Air Cylinder DXSL20X15
AirTAC Air Cylinder JSI100X400S
MINDMAN Air Cylinder MCMI-11-25-550-A
MINDMAN Air Cylinder MCJQ-12-25-30M
Festo Air Cylinder DPZ-16-10-P-A-KF-S2
AirTAC Air Cylinder TN20X20S
CKD Air Cylinder BHA-03CS1-O
Festo Air Cylinder DGSL-16-20-PA
Autonics Rotary Encoder E40H8-800-3-T-24
Honeywell Actuator M6294F1009-F
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CCS Switch 6900DZEM10
GE Circuit Breaker FDN36TD040ED
Daikin Solenoid Valve KSOB-G02-2BP-30-N
VECTOR Transmitter SDC-H1T1-08-A2-LCD
Recent related posts
-
06/14/2020
What is the energy efficiency ratio of air conditioning
What is the energy efficiency ratio of air conditioning What does the air-conditioning energy efficiency ratio mean? How to calculate the air-conditioning energy efficiency ratio?
-
09/14/2020
Selection guide for air compressor
Selection of working pressure (exhaust pressure): When the user is preparing to purchase an air compressor, first determine the working pressure required by the air end, add a margin of 1-2 bar, and then select the pressure of the air compressor (the margin is considered from the air compressor The pressure loss from the installation site to the actual gas end pipeline distance, according to the length of the distance between 1-2 bar, appropriately consider the pressure margin)
-
06/28/2022
Introduction to Priming in Pumps
Priming a piston pump is probably the first and one of the most important thing one should do before operating it. Not priming a pump or not doing it properly makes majority of pump problems.
-
03/22/2022
What is an Expansion Valve?
The expansion valve is an important part of the refrigeration system and is generally installed between the liquid storage tank and the evaporator.
-
02/13/2023
What is the Gearbox?
The gearbox, also called transmission that can changes the speed of a motor, is a power transmission device.
-
06/14/2020
Do summer air-conditioning rooms need air purifiers
Do summer air-conditioning rooms need air purifiers It is high temperature in summer again. Many people have disputes about whether an air purifier is needed in summer.
-
02/05/2024
Exploring the Wonders of Fan Ovens: A Comprehensive Guide
In the realm of modern kitchen appliances, the fan oven stands as a testament to innovation and efficiency. As culinary technology continues to advance, the fan oven has become a staple in many households, revolutionizing the way we bake, roast, and prepare our favorite dishes.
-
09/23/2020
Air compressor classification, working principle and air compressor selection
Air compressor classification, working principle and air compressor selection The air compressor is the main body of the air source device. It is a device that converts the mechanical energy of the prime mover (usually an electric motor) into gas pressure energy, and is a pressure generating device for compressed air.
-
02/24/2020
Why is the air conditioner not cooling
1.Check whether the compressor is working normally. If the compressor is broken, the air conditioner cannot start normally and there will be no cooling effect. 2. There is not enough refrigerant in the air conditioner. At this time, you need to add Freon, and the time for adding Freon can be very long. 3. The air conditioner itself has quality problems and the electrical components have failed. In this case, you need to find a master to repair it.
-
07/30/2020
Causes and troubleshooting of industrial chillers
1. High condensing pressure (higher than the specified value) failure causes and remedies:<br></br> ①There is non-condensable gas in the system: release non-condensable gas.