Please click Send us the order information , we will contact you as soon as possible !
Mitsubishi VFD Frequency Converter FR-F740-S315K-CHT
Please click Send us the order information , we will contact you as soon as possible !
People who bought this item also viewed
Panasonic Servo Drive MDDDA103A1A
Dynapar Encoder H232500022545
HITACHI VFD Frequency Converter SJ100-015HFU
COSEL Power Supply LFA240F-36-TY
DAYTON Speed Reducer 1LPL9
MITSUBISHI Spindle Amplifier MDS-B-SPJ2-15
LR-LINK NIC Card LRESS2031PT
Beckhoff Coupling Module BK2000
Fuji Relay HH63P
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CKD Air Cylinder FCD-L-40-10
Recent related posts
-
08/14/2023
Are Window Heat Pumps Efficient? (Window Heat Pump: Everything You Need to Know)
Window heat pumps (heat pump window units, window unit heat pumps) are a popular heating and cooling solution for homes and apartments. They are affordable, easy to install, and can help save energy compared to other heating and cooling options.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/01/2020
Talking about the advantages of compressor enthalpy increasing technology
Talking about the advantages of compressor enthalpy increasing technology The air-jet enthalpy-increasing compressor adopts two-stage throttling intermediate air-jet technology, and uses a flash evaporator to separate gas and liquid to achieve an enthalpy-increasing effect. This compressor jet enthalpy increasing technology has many advantages, as follows:
-
07/27/2020
The working principle of screw unit and common failure analysis
1. Refrigeration cycle and pressure enthalpy diagram<br></br> The refrigeration cycle of a screw chiller can be represented by a pressure-enthalpy diagram. The main state points are shown in the diagram, which will be used in the following discussion.
-
06/29/2020
Causes of non-condensable gas in refrigeration system
Causes of non-condensable gas in refrigeration system 1. Insufficient emptying of the refrigeration system before charging the refrigerant Before charging the refrigerator, the compressor cylinder in the refrigeration system, the condenser, the evaporator, and the piping of the system were filled with air. In order to eliminate these air before charging the refrigerant, the interior of the refrigeration system Vacuuming,
-
07/07/2023
Why Heat Pump Compressor Starts Then Stops: Common Causes and Solutions
A heat pump compressor that starts and then stops can be a frustrating and potentially costly issue. A malfunctioning compressor can cause inefficient operation, poor heating or cooling performance, and even complete system failure.
-
06/30/2020
Broken suction valve of Bristol compressor
Broken suction valve of Bristol compressor A Bristol compressor is a machine that compresses gas. Generally, the piston compresses gas 1450 times per minute (half-sealed compressor) or 2900 times (full-sealed compressor), that is, the time to complete an intake or exhaust process is 0.02 seconds or even shorter.
-
08/16/2020
What are the problems with the fan system of air-cooled refrigerators
The fan system of an air-cooled refrigerator is an important part of the air-cooled refrigerator system. The air-cooled refrigerator uses the fan system to dissipate heat for cooling.
-
08/15/2020
What should I do if wall cracks appear after the cold storage is built
After the construction of the cold storage project, there may be many problems. For example, we have seen a lot of news recently. It is said that the wall cracks appeared after the construction of the cold storage
-
06/14/2020
New energy efficiency standards for air conditioners are officially implemented
New energy efficiency standards for air conditioners are officially implemented Recently, a major event has occurred in the air-conditioning industry, and the new energy efficiency standard has confirmed the implementation time.