9 usage details that affect the life of air conditioners 1. Clean the air filter frequently. Usually clean once every 2-3 weeks. The steps are: remove the panel; pull out the air filter; clean the air filter. Rinse the air filter under the tap. Since the filter is made of plastic frame and polyester silk, it should not be cleaned with hot water above 40℃ to prevent shrinkage and deformation. After cleaning, you can dry the water on the filter, insert the panel, and install the air conditioner. 2. Protect the heat sink of the condenser and evaporator. The radiating fins of the condenser and evaporator are made of 0.15mm aluminum sheet inserted into the copper tube and then expanded. It cannot withstand collisions. If the radiating fin is damaged (rewinding), it will affect the heat dissipation effect of the air conditioner and make cooling The efficiency is reduced. Therefore, pay special attention to protection. Three, protect the refrigeration system. If the components or connecting pipes of the refrigeration system are damaged, the refrigerant will leak, and the air conditioner cannot be cooled. Fourth, the correct selection of fuses (fuses). Choose the specifications of the fuse wire according to the rated current indicated in the product manual. If it is too large, it will not be insured, and if it is too small, it will often blow. 5. The operation time of manual stopping and opening of the air conditioner should be more than 2 minutes apart, and continuous stopping and opening is not allowed. 6. Prevent the electrical system from getting wet. The electrical system is prone to leakage after being damp. Therefore, the electrical system parts should not be exposed to water, especially in the summer and rainy seasons, and pay attention to moisture. Seven. Always check whether the power plug is in good contact with the socket, and there should be no looseness or fall off. 8. Pay attention to the operating sound of the air conditioner. When you hear abnormal noises during operation of the air conditioner, such as metal collision, motor buzzing, shell vibration, etc., you should immediately shut down and check the cause, and you must not continue to use it blindly to avoid greater damage. Nine, often wipe the outer surface of the air conditioner, especially the panel part, to keep the air conditioner clean. Use a long-bristled brush to clean the dust on the outdoor cooler every six months. Remove the movement every year and inject appropriate lubricating oil into the fan motor bearings. The refrigeration system does not need to be processed, as long as the external dirt is removed.
9 usage details that affect the life of air conditioners
Recent related posts
-
07/23/2020
9 usage details that affect the life of air conditioners
1. Clean the air filter frequently. Usually clean once every 2-3 weeks. The steps are: remove the panel; pull out the air filter; clean the air filter. Rinse the air filter under the tap. Since the filter is made of plastic frame and polyester silk, it should not be cleaned with hot water above 40℃ to prevent shrinkage and deformation.
-
07/23/2020
Share┃Causes and solutions for ice block, dirty block, and oil block
Foreword: The blockage of the refrigeration system is mainly caused by the ice blockage, dirty blockage or oil blockage of the capillary tube, or the dirty blockage of the dryer filter.
-
07/23/2020
R410a and R22 refrigerant comparison application and installation specifications
1.Introduction to the properties of R410a refrigerant<br></br> 1. R410a is a HFCs refrigerant mixed with two working fluids of R32 and R125 at a mass fraction of 50% and 50%. It is a near-azeotropic mixture (pseudo-azeotrope), and its thermal performance is close to a single working fluid.
-
07/23/2020
Do you know the causes, hazards, treatment and prevention methods of compressor liquid strike?
Liquid hammer refers to the situation in which the refrigerant liquid or wet vapor is sucked into the compressor by the compressor due to the failure or insufficient heat absorption and evaporation of the refrigerant, which is called liquid hammer.<br></br> <br></br>
-
07/23/2020
The influence of capillary tube length on refrigeration system parameters and troubleshooting
The capillary tube generally refers to a slender copper tube with an inner diameter of 0.4~2.0mm. As the throttling mechanism of the refrigeration system, the capillary tube is the simplest one. Because of its low price and flexible selection, it is widely used in small refrigeration devices.
-
07/23/2020
Shallow oil return method of parallel refrigeration compressors
Compressor oil return is one of the key problems in piping design, and it is also a troublesome problem that must be solved; the solubility of refrigerant and lubricating oil should be miscible, slightly soluble, and miscible at high pressure and separate at low pressure. ; The problem of oil return often occurs in the exhaust pipe and return pipe. Today, the analysis is the oil return problem of parallel compressors
-
07/23/2020
Why does refrigeration equipment particularly emphasize installation
Hidden danger 1: The refrigerant pipe enters dust and impurities<br></br> Dust and impurities in the refrigerant pipeline will cause the effect of the central air conditioner to decrease, increase the wear of the central air conditioner compressor, and cause the central air conditioner to block and affect the cooling effect.<br></br><br></br>
-
07/23/2020
Analysis of Overheating Failure of Refrigeration Compressor
The main reasons for the overheating of exhaust temperature are as follows: high return air temperature, large heating capacity of the motor, high compression ratio, high condensation pressure, and improper refrigerant selection.<br></br> <br></br>
-
07/23/2020
Reasons for excessively high discharge temperature of refrigeration compressor (technology sharing)
The refrigeration compressor is the core and heart of the refrigeration system. The capacity and characteristics of the compressor lead to the capacity and characteristics of the refrigeration system. In a sense, the design and matching of the refrigeration system is to reflect the capacity of the compressor.
-
07/23/2020
Trouble and overhaul of piston refrigeration compressor
1. The refrigeration compressor cannot start normally Maintenance ideas 1. First, check whether it is caused by low power supply voltage or poor connection of the motor circuit. If it is indeed that the grid voltage is too low, restart after the grid voltage returns to normal: If the line is in poor contact, the connection between the line and the motor should be detected and repaired.