How to switch freely between cooling, heating and dehumidification modes
Nowadays, the air conditioner has become a must-have household appliance for every household. In different seasons, for us, we can adjust the temperature with our fingers and realize the switching of different functions. But you know that when you press the button, what happens in the air conditioner How about the change? Today, the editor of okmarts.com will take you to understand the relevant knowledge.
To understand the operating principle of the air conditioner, we must start with the internal structure of the air conditioner. The air conditioner we commonly use is generally a split air conditioner, which consists of two parts: the outer unit of the air conditioner and the inner unit of the air conditioner. The outer unit is placed outdoors with a condenser and compressor. The internal machine is placed indoors, which contains an evaporator, an expansion valve and a cross flow fan. It should be noted that the condenser and the evaporator are actually heat exchangers, but they are called different names according to different uses.
Refrigeration cycle
In the refrigeration cycle, the air conditioner reduces the refrigerant pressure through the expansion valve to lower the boiling point of the refrigerant, so that the refrigerant boils in the indoor evaporator and turns into vapor. The vapor flows to the outdoors, and then pressurized by the compressor to liquefy and then The absorbed heat is released, and then flows back into the room, and the reciprocating cycle continues, and the indoor heat is carried to the outdoors.
heating cycle
In the heating cycle, the four-way valve used in the air conditioner allows the refrigerant to flow in the opposite direction to the refrigeration cycle. The specific cycle is: the compressor pressurizes the refrigerant and sends the high-pressure gaseous refrigerant to the indoor heat exchanger, and the refrigerant liquefies to release heat.
But in winter, there is a large temperature difference between indoor and outdoor. Many domestic air conditioners are equipped with electric auxiliary heating. Electric auxiliary heating is similar to a hair dryer. It is to install a heating wire at the air outlet to warm the wind.
dehumidification mode
For dehumidification, when the air conditioner is cooling, the indoor evaporator is constantly absorbing heat, and the temperature will be in a lower state. In order to make the cooling more efficient, the blower continuously sucks indoor air through the evaporator to speed up the heat exchange process. When the air is cooled, the moisture in the air becomes condensed water, which is finally collected in the water collector and discharged outside. Therefore, in fact, the air conditioner works in the cooling mode with a certain degree of dehumidification. The dehumidification mode is also designed according to this principle, so how can we make this dehumidification process more efficient and make dehumidification independent as a function?
In the dehumidification mode, engineers lowered the speed of the compressor and blower to allow enough time for the water vapor in the air to condense, thereby improving the dehumidification efficiency and making it an independent function.
Since dehumidification is accompanied by refrigeration, how do those high-end air conditioners on the market claim to be able to dehumidify at a constant temperature?
The answer is actually very simple. This type of air conditioner only heats the cooled air during air supply, so that people will not feel the temperature drop while dehumidifying, making the dehumidification function a function that can be used all year round.
It should be noted that in summer, when the temperature is set to 26~27 degrees Celsius, the cooling load can be reduced by more than 8%; when heating in winter, the temperature is set 2 degrees Celsius lower, which can also save 10% of electricity; when a person sleeps, the metabolism Reduce 30%~50%, set the air conditioner to sleep mode, set the temperature to 2 degrees Celsius higher, and save 20% of electricity.
Practice has also proved that for people who sit quietly or work lightly, if the room temperature is maintained at 28~29 degrees Celsius and the relative humidity is maintained at 50%~60%, people will not feel stuffy and sweat, which belongs to the comfortable range.
How to switch freely between cooling, heating and dehumidification modes
Recent related posts
-
08/24/2020
How to switch freely between cooling, heating and dehumidification modes
Nowadays, the air conditioner has become a must-have household appliance for every household. In different seasons, for us, we can adjust the temperature with our fingers and realize the switching of different functions.
-
08/24/2020
How long is the service life of the refrigerator
Currently, there is no mandatory standard for the service life of electrical appliances.<br></br> The "Safety Life of Household Appliances" formulated by the Household Appliances Industry Association specifies that the safe use of refrigerators is 10 years.
-
08/24/2020
How can humidification and refrigeration equipment companies reduce their operating costs and improve efficiency through CRM systems
Although 2020 has now entered the summer, many companies are still in the cold winter due to the impact of the epidemic. Our Zhiyuntong CRM sales management system provides online support for every company in the cold winter.
-
08/24/2020
Honeywell Connected People Solution Helps Wood Group Ensure Business Continuity
Honeywell recently announced that Wood has adopted Honeywell's Connected Personnel Productivity Solution to improve decision-making, increase productivity, and ensure the safety of industrial personnel.
-
08/24/2020
Health sterilization is sought after, air-conditioning innovation boosts market recovery
Since the beginning of this year, affected by the new crown pneumonia epidemic, the development of the air-conditioning industry has been relatively difficult.
-
08/24/2020
Guidelines for the scientific wearing of masks by the public (revised edition) and summer air-conditioning operation management and use guidelines (revised edition) released
Guidelines for the scientific wearing of masks by the public (revised edition) and summer air-conditioning operation management and use guidelines (revised edition) released
-
08/24/2020
Do cold storage maintenance, you must understand this knowledge!
1. "Three Preventions" of the Refrigeration System 1. Prevent the evaporation temperature from being too low The increase in the temperature difference between the evaporating temperature and the warehouse temperature will make the evaporating temperature too low
-
08/24/2020
Central air conditioning In 2020, enter the era of stock
In 2020, no one will be able to make an accurate assessment of international political patterns and economic development trends. In the short term, central air-conditioning is gradually transitioning from an incremental market to a stock market.
-
08/24/2020
Causes of uneven liquid distribution in refrigeration systems and tragic cases!
If the distribution head is not evenly distributed, it will cause too much refrigerant in some of the branches, which will cause the evaporator to frost.
-
08/24/2020
Beware of invisible pollution in air conditioning in summer
"My God, I can't believe that the air conditioner that is blown every day is so dirty." Mr. Huang, who lives in Jiqingmen, said in surprise after opening the air conditioner.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X