Safety Operating Regulations for Freon Refrigeration Compressor Unit Safety Operating Regulations for Freon Refrigeration Compressor Unit Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them. One, preparation before starting The preparation work before starting the equipment includes the following: (1) Clean the environment around the equipment site, and deal with the cleanliness of the equipment body and related auxiliary equipment. (2) Check the power supply voltage. (3) Check the on-off conditions and liquid level of various valves in refrigeration equipment. (4) The capacity adjustment device should be placed in the minimum gear to facilitate the no-load start of the refrigeration compressor. (5) Check whether there is water in the pool on the evaporating condenser, and if there is water shortage, make up for it in time. (6) Ensure that the oil level is correct, 1/8 to 3/8 of the sight glass. (7) All temperature controls are set at the expected operating temperature value. (8) Ensure that no liquid refrigerant enters the compressor. The liquid is incompressible and will damage the compressor. Freon Refrigeration Compressor Unit Safety Operation Regulations 2. Start-up and operation of refrigeration equipment During the start-up operation of the refrigeration equipment, attention should be paid to the start-up procedures, the content and period of the operation inspection inspection, and the main adjustment methods in operation to guide the correct start-up of the equipment and ensure the normal operation of the equipment. (一) The startup procedure is as follows: (1) First, start the water pump and fan on the evaporative condenser. (2) Each time you start a compressor, turn the switch of the compressor to the automatic gear to start operation, and observe whether the compressor is running abnormally. If there is an abnormal sound, immediately shut down the compressor for inspection. Restart after troubleshooting. The usual reasons for the abnormality are: 1, insufficient or excessive freezing oil; 2, The unreasonable installation or management connection of the unit causes excessive vibration; 3, Compressor hydraulic machine. (二) Matters needing attention for inspection during equipment operation After the equipment is started up and put into normal operation, the inspection should be strengthened to find the problem in time and deal with it in time. The main contents of the inspection are: 1. The oil pressure, oil temperature, bearing temperature, and oil level during the operation of the refrigeration compressor; 2. The temperature of the cooling water at the inlet of the condenser and the temperature of the refrigerant water at the outlet of the evaporator; 3. The operating current of the motor when the compressor, cooling water pump, and fan are running, and the flow of cooling water and refrigerant water; 4. Compressor suction and discharge pressure values, sound and vibration of the entire refrigeration unit during operation. (3) Precautions for defrosting in cold storage 1. First, stop the liquid supply of the evaporator that needs to be defrosted and draw back its original liquid, and adjust the defrost valve; 2. Defrosting with warmed water; 3. Before defrosting, reduce the pressure in the drain barrel to the evaporation pressure and adjust the relevant valves; 4. After the defrosting operation is over, you must wait at least 30 minutes before turning on the fan to prevent freezing and blocking the pipeline; 5. According to the frosting situation of the freezing storage and the evaporator of the cold storage, the defrosting operation shall be carried out in time. Three, shutdown procedures and precautions Turn off the electronic valve first, and then turn off the compressor after the suction pressure of the compressor reaches the set value, so as not to make the pressure of the low pressure system too high after shutdown, but not too low, not lower than the atmospheric pressure, to avoid air infiltration refrigerating system. is stopping the evaporator fan, and finally the condenser water pump and fan. In the shutdown process, in order to ensure the safety of the equipment, the evaporator should be operated for a period of time after the compressor is shut down. Once the refrigerant in the evaporator is vaporized, all the refrigerant in the condenser is liquefied. Operate according to the steps described above, the whole operation process is smoother and the error rate is lower.
Safety Operating Regulations for Freon Refrigeration Compressor Unit
Recent related posts
-
07/22/2020
Safety Operating Regulations for Freon Refrigeration Compressor Unit
Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
07/22/2020
The refrigerator is not cooling, and the compressor ‘buzzes’ after turning on the battery for a few seconds. What's the matter?
A few days ago, I received a call from a customer asking for repairs, saying that her refrigerator had suddenly stopped cooling in the past two days. The light bulb in the plug-in fresh-keeping room was on, and no movement was heard.
-
07/21/2020
How to protect the refrigeration compressor, you must master the following knowledge!
When the compressor is running, some abnormal conditions may occur, such as: exhaust pressure is too high, suction pressure is too low, oil pressure is insufficient, motor is overheated, excess liquid enters the cylinder, etc. In the event of an abnormal situation, the compressor will be damaged if there is no protective measure.
-
07/21/2020
Basic knowledge of refrigeration compressor (technology sharing)
Compressor, a driven fluid machine that promotes low-pressure gas to high-pressure gas. It is the heart of the refrigeration system. It sucks in low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and discharges the high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle. Compression → condensation (heat release) → expansion → evaporation (heat absorption) refrigeration cycle.
-
07/21/2020
11 common protection devices for refrigeration compressors
When the compressor is running, some abnormal conditions may occur, such as: exhaust pressure is too high, suction pressure is too low, oil pressure is insufficient, motor is overheated, excess liquid enters the cylinder, etc. In the event of an abnormal situation, the compressor will be damaged if there is no protective measure.
-
07/21/2020
Ten basic performance parameters of refrigeration compressors (technology sharing)
Under a certain working condition, the gas mass delivered from the suction end to the discharge end per unit time is called the compressor mass air delivery under this working condition, and the unit is. If calculated according to the volume of the inhalation state, the volume of the air delivery is, and the unit is then
-
07/21/2020
Analysis of the application advantages and disadvantages of the five major refrigeration compressors
At present, semi-hermetic piston compressors are mostly used in the cold storage and freezing and refrigeration markets (commercial refrigeration and air conditioning are also useful, but they are relatively less used now). The semi-enclosed piston cold storage compressor is generally driven by a four-pole motor, and its rated power is generally between 60-600KW. The number of cylinders is 2-8, up to 12.
-
07/21/2020
Do you know several common refrigeration compressors?
1. Semi-sealed piston refrigeration compressor Among the various types of refrigeration compressors, the piston compressor is the first one that has come out and is still in use. For example, semi-hermetic piston refrigeration compressors are widely used in refrigeration equipment. Common manufacturers are: Emerson, Bitzer, Sanyo, Duling and other compressors.
-
07/20/2020
Six aspects of repair and maintenance of refrigeration compressors in cold storage
A. During the initial operation of the cold storage unit, carefully observe the oil return of the compressor and keep it clean. If you find that the oil level is not clean enough or if the oil level drops, you should add oil or replace it with new oil in time. This can avoid poor lubrication
-
07/20/2020
Pay attention to these for compressor maintenance safety!
Oxygen blowing system is forbidden: Oxygen is colorless, odorless, non-toxic, non-combustible and non-explosive. However, mixing with other combustible or explosive gases will promote combustion or explosion;