The reason for the water seepage at the outlet of the central air conditioner
The spring equinox is over, and the temperature will slowly rise. The hot summer will soon come. Whether it is traditional air conditioning or central air conditioning, it will soon come in handy. However, many people have found that the problem of water leakage from the air conditioning blower is extremely common. The air outlets of central air conditioners are generally hidden in the ceiling and walls, and long-term water seepage will have a certain impact on the indoor environment. Therefore, solving the problem of water seepage in the air outlet of the central air conditioner has become a topic of concern to everyone. Let's take a look at how to solve the problem of water seepage in the air outlet of the central air conditioner.
Why does water seep? It may be a problem with the air outlet panel!
As the saying goes: Unlock the bell and return the bell to the person who wants to solve the problem of water seepage. You need to start with the reason first. The air outlet panel is one of the main factors. For the panel of the air outlet, many customers always choose aluminum alloy panel, thinking that it is tall and durable, and the price is high. The engineering plastic panel feels a little softer, and the grade may not be high. So almost all use aluminum alloy panels. As everyone knows, the engineering plastic panel is also very solid, and the effect is no different from the aluminum alloy panel after installation.
At the same time, because engineering plastics are not as sensitive to changes in cold and heat as aluminum alloys, when the cold air from the air-conditioning outlet blows outwards and intersects with the higher indoor air, water will not appear immediately like aluminum alloy panels. Condensation and condensation drip water. Therefore, strictly speaking, aluminum alloy panels should be eliminated to avoid misleading users of high-end decoration.
How to solve it effectively? Perform overall system settings for central air conditioning
In fact, regarding the dripping of the tuyere, the setting of the entire central air-conditioning system is also a very important aspect. On hot days, customers turn on the air conditioner after they arrive home, and often want to set the temperature below the standard temperature in one step. If the air conditioner installation company sets it reasonably in advance, even if the air conditioner is set below the standard temperature when it is turned on, it will Let the air out first, it is a little cool, and then gradually cool down by yourself, so that the temperature of the air outlet panel is gradually reduced to adapt to the higher indoor temperature, so that the temperature of the air outlet panel will drop in one step and cause condensation and dripping, thus solving the problem The problem of condensate leakage.
For a series of problems of water seepage at the air outlets of central air conditioning, we also need to rely on very detailed analysis to solve the problems. Among them, it is very important to pay attention to the air outlet panel and the entire system setting. Knowing these two issues will have a good effect on our treatment of air outlet dripping. Users also need to provide for both aspects. Focus on attention and be ready to take some effective measures against dripping.

Related Info
The function and setting of the oil trap in the refrigeration system The heat pump is prone to frost between +4~-4℃. The symptoms and reasons are not beyond these 10 points. The main difference between the appearance of the evaporator and the condenser The most basic maintenance skills for air conditioner failure The quality of the cooling medium affects the cooling effect of industrial chillersThe reason for the water seepage at the outlet of the central air conditioner
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
LS/LG HMI XP10BKA/DC
Contact Us
HONGFA Relay HF41F-12-HT
US$1.54
Carrier Expansion Valve 33B0043N04
Contact Us
Siemens Power Supply 6EP3446-8SB00-0AY0
US$524.49
NMB-MAT Fan 1604KL-01W-B50
US$13.46
PIZZATO Switch FL601
Contact Us
Fuji VFD Frequency Converter FRN005C1S-6A11
Contact Us
TOKIMEC Vane Pump V20-1P8P-3A11L-JA-J
Contact Us
SUNON Fan A2123-HST
US$75.00