The specific maintenance content of the cooling tower equipment of the chiller
We know that the international cooling water tower is a structure used for cooling water in power plants, and the general height is determined by the size of the power plant units. Next, we fully explain the specific maintenance content of the cooling tower equipment of the chiller.
1. Operation record. When the FRP cooling water tower is constructed or installed and put into operation, the design unit or manufacturer shall provide all the characteristic data of the cooling water tower: including thermal characteristics, resistance characteristics, water load, heat load, ambient temperature, cooling range, air flow rate, concentration Multiplying factor, fan power consumption, water pressure entering the tower, etc.
2. Measuring instruments and methods. In order to detect the operating effect of the glass fiber reinforced plastic cooling water tower, or to evaluate the size of the cooling capacity, it is necessary to conduct an indoor test or an identification test on the operating cooling water tower at the production site. Therefore, it is not only necessary to have scientific and technical personnel for the cold water tower test and research, but also a complete set of test methods that meet the specifications.
3. Cooling water collection tank. The cold water sump should maintain the water depth of the pool to prevent cavitation. The freeboard height of the sump is 15~30cm, and the following is the effective volume of the pool. The water level of the pool should be maintained at a certain level, otherwise the supplementary water valve needs to be adjusted. For cross-flow cooling water towers, if the operating water level is lower than the design requirements, an air baffle should be installed below the original water surface to prevent air from bypassing.
The cold pool of the air-cooled chiller should be cleaned irregularly to remove the sludge and adhesions deposited on the bottom of the pool, remove the debris from the filler and its support, keep the grille of the pump suction port clean, and inspect it from time to time If the leakage of the collection tank needs to be repaired, attention must be paid to the normal operation of the acid, chlorine, and water quality stabilizing agent distribution device.
The specific maintenance content of the cooling tower equipment of the chiller
Recent related posts
-
08/17/2020
The specific maintenance content of the cooling tower equipment of the chiller
We know that the international cooling water tower is a structure used for cooling water in power plants, and the general height is determined by the size of the power plant units.
-
08/17/2020
The setting of fire damper in HVAC system
In the HVAC design, there are many types of valves for fire prevention and smoke exhaust, and the valve settings are different for different applications.
-
08/17/2020
The reason for the water seepage at the outlet of the central air conditioner
The spring equinox is over, and the temperature will slowly rise. The hot summer will soon come. Whether it is traditional air conditioning or central air conditioning, it will soon come in handy.
-
08/17/2020
The quality of the cooling medium affects the cooling effect of industrial chillers
After enterprises purchase industrial chillers, when the cooling performance of industrial chillers decreases during operation, many enterprises think that it is related to the failure of industrial chillers.
-
08/17/2020
The most basic maintenance skills for air conditioner failure
1. The most basic maintenance skills for air conditioner failure The air conditioner is composed of a refrigeration system and an electrical system, and its operating state is closely related to the working environment and conditions,
-
08/17/2020
The main difference between the appearance of the evaporator and the condenser
Both the evaporator and the condenser actually have their own advantages, but the principle is actually figured out, so what is the main difference in appearance between the two, I will take you to understand.
-
08/17/2020
The heat pump is prone to frost between +4~-4℃. The symptoms and reasons are not beyond these 10 points.
The air source heat pump can use the low-grade heat energy in the ambient air, so it has the dual advantages of energy saving and environmental protection. However, one of the problems is that
-
08/17/2020
The function and setting of the oil trap in the refrigeration system
In the Fuli Subaru refrigeration and air-conditioning system, when the main engine is higher than the end (evaporator), there is a riser pipe between the evaporator and the main suction pipe,
-
08/17/2020
The function and selection method of throttling capillary in industrial chiller
The capillary tube in the industrial chiller is a pure copper tube with a specified length and a very thin diameter. Its inner diameter is generally between 0.5-2mm. Choose the appropriate length according to the size of the chiller, and then process it i碌7館2 䀀 締眪
-
08/17/2020
The difference between a single-head chiller and a double-head chiller
1. Single-stage refrigeration system 1. The single-stage refrigeration cycle refers to the four processes of compression, condensation, throttling,
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
Yaskawa Servo Motor SGMPH-15AAA4B
YUKEN Vane Pump A145-FR04EK-10
Sanyo Denki Fan 9G0848P1G041