What is the four-pipe air conditioner Under what circumstances
Four-pipe air-conditioning means that the air-conditioning box is equipped with cold coils and hot coils at the same time. Each group of coils is fed one time, a total of four, so it is called four-pipe. Two sets of water pipes are connected to cold water and hot water respectively, that is, cooling and heating can be switched at any time throughout the year, which can realize heating in some rooms while cooling in other rooms. So it has high standards and high costs
Advantages of four control systems:
①Each terminal device can freely choose the operating mode of heating or cooling at any time, without mutual interference, and the air-conditioned areas served can independently control temperature and other parameters;
②Save energy, all energy consumption in the system can be provided according to the requirements of the end, unlike the three-pipe system, there is no problem of cold and heat offset.
The two-pipe air-conditioning box is just a set of coils, one in one, cold water in summer and hot water in winter. Such a system makes the entire area only available for cooling or heating at the same time. Compared with the four pipes, it saves a set of water system, so its standard is relatively low, and the cost is also low.
Disadvantages of the four control system:
① Large investment, relatively complicated operation and management
②As there are more pipelines, the system design becomes more complicated, and the pipeline takes up a lot of space.
Due to these shortcomings, the use of this system is subject to some restrictions.
What is the four-pipe air conditioner Under what circumstances
Recent related posts
-
08/02/2020
What is the four-pipe air conditioner Under what circumstances
Four-pipe air-conditioning means that the air-conditioning box is equipped with cold coils and hot coils at the same time. Each group of coils is fed one time, a total of four, so it is called four-pipe.
-
08/02/2020
The hazards and causes of high exhaust temperature of cold storage compressor
The discharge temperature of cold storage compressors should generally be 15~30℃ lower than the flash point of the lubricant, and not too high.
-
08/02/2020
How to manage the temperature after the cold storage is built
After the cold storage is built, the temperature in the cold storage must be better adjusted. This content is actually very important, but the corresponding precautions should also be grasped in the process of adjusting the temperature of the cold storage.
-
08/02/2020
How does the cooling, heating, and dehumidification mode switch freely
Nowadays, almost every home has air-conditioning, which is cooled in summer, which brings coolness, heat in winter, provides warmth, dehumidification in the rainy season, and creates a refreshing environment.
-
08/02/2020
Refrigerator refrigeration system leak detection
The refrigeration system should be tested for leaks due to refrigerant leakage or refrigerators after replacing parts. The following three methods are generally used for leak detection in refrigeration systems
-
08/02/2020
Basic principles of data center cooling and energy saving solutions
Basic principles of data center cooling and energy saving solutions<br></br> Each data center has its own characteristics, so there is no technical solution that can be applied to any data center.
-
08/02/2020
Introduction to the knowledge of central air conditioning vents
Introduction to the knowledge of central air-conditioning vents The correct installation and design of central air-conditioning is very important.
-
08/01/2020
The new era of dual-supply air-conditioning refrigeration, floor heating and heating trend has arrived
For heating equipment, many people will have doubts. The central air conditioner installed in the home already has heating function. Do you need to install floor heating?
-
07/31/2020
How to judge the freezer has aged
Long-term use of the freezer will cause some large and small problems. The freezer in many people's stores has gradually become aging for some years
-
07/31/2020
The reason why the freezer glass door is not closed tightly
The glass door of the freezer is not closed tightly. This problem occurs in both domestic and commercial freezers. When we are at home, we rarely pay attention to whether the door of the freezer can be closed tightly.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
VTOZ Overflow Valve WKG-033-210-V
AirTAC Air Cylinder TCMJ40X200-20S
Honor Gear Pump 1GG1B35R