There is no price at present, you can Request a Quote
Repeatability: ±2% FS
Turndown Ratio: 50:1
Response Time:
FLR-1600A: 20 ms
FLV-4600A: 100 ms
Input Control Signal
(FLV-4600A Units):
0 to 5 Vdc and RS232
Output Signal: 0 to 5 Vdc, RS232
Optional Input/Outputs:
4 to 20 mA, 0 to 10 Vdc
Operating Temperature:
10 to 50°C (50 to 122°F)
Zero Shift: 0.02%/ATM FS/°C
Span Shift: 0.02%/ATM FS/°C
Excess Flow Rate:
Approx 28% overage
Maximum Pressure:
Meters: 200 psig
Controllers: 150 psig
Minimum Pressure Drop: 0.4 psid
Supply Current (Typical):
FLR-1600A: 30 mA
FLV-4600A: 250 mA
Supply Voltage:
FLR-1600A: 7 to 30 Vdc, 0.035 A
FLV-4600A: 12 to 30 Vdc, 0.250 A
Note: 15 Vdc minimum for 4 to 20 mA
output option.
Electrical Connections:
8-pin circular mini DIN
Omega Flowmeter FLR-1605A-V2
There is no price at present, you can Request a Quote
People who bought this item also viewed
NIVELCO Level Meter SPB-390-4
Apure Turbidity Meter TS-620
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Autonics Sensor BJ100-DDT-P
Mitsubishi Servo Motor HC-PQ053D
Banner Sensor Q4XTBLAF300-Q8
Schneider Circuit Breaker LS8O11501G
CKD Air Cylinder SCA2-FA-63B-350-T0H-D
Daikin Solenoid Valve KSO-G02-91CD-30
Recent related posts
-
08/12/2020
How to configure the cold storage refrigeration equipment
How to configure the cold storage refrigeration equipment? The full set of refrigeration equipment installation quotation for Yuncheng cold storage, okmarts.com Refrigeration, as a cold storage overall solution provider, has rich experience in cold storag¨ﰨ2 䀀 湠疨 V ǜ V
-
10/21/2023
Why Does My AC Keep Freezing Up at Night?
During the hot summer months, a well-functioning air conditioning (AC) system is crucial to maintaining a comfortable indoor environment. However, if your AC keeps freezing up at night, it can be a frustrating and perplexing problem.
-
07/19/2020
Have you mastered the general troubleshooting methods for ammonia refrigeration
In the refrigeration system of the cold storage, the refrigeration compressor is the core equipment, usually called the refrigeration host. At present, piston refrigeration compressors are mostly used in small and medium-sized cold storage refrigeration systems. Due to the different refrigerants,
-
07/27/2020
How much do you know about air conditioning Remove the air-conditioning mystery layer by layer
The working principle of air conditioning supplements the fourth and fifth points:<br></br> Compressor<br></br>
-
08/19/2020
Can the fresh air system, air purifier and air conditioner replace each other
1. Fresh air system Fresh air system is based on the use of special equipment on one side of a closed room to send fresh air to the room, and then discharge from the other side by special equipment to the outside,
-
06/29/2020
Semi-closed piston refrigeration compressor 4SJH-3000
Semi-closed piston refrigeration compressor 4SJH-3000 Features of semi-hermetic piston compressor 4SJH-3000: 1. Light in size and small in space 2. Suitable for R12, R22 and R502, with a wide range of applications
-
09/04/2020
Have you heard of the 6S management of the compressor station on-site
For compressor users, on-site management is one of the daily management content of each enterprise.
-
09/14/2020
Common troubleshooting methods for twin screw compressors
Common troubleshooting of twin screw compressor 1. Trouble phenomenon The exhaust temperature of the unit is high (over 100 degrees) The coolant level of the unit is too low (should be visible in the oil glass but not more than half) Dirty oil cooler
-
11/22/2023
How to Keep Your Computer Cool (Desktop, Laptop, or Computer CPU Temperature is too High)
The main sources of heat in a computer are the processor (CPU) and graphics processing unit (GPU). When these components work, they generate a lot of heat.
-
07/14/2020
What's wrong with the freezer not cooling
1. Test the power cord with an electric pen. The broken power cord of the freezer is also a cause of non-refrigeration. For this situation, we need to check whether it is a power problem. The general approach is to open the door and observe whether the lighting lamp in the box Light up. Look for signs of damage to the wires, such as being bitten by a mouse.