Series:Rectangular type
Housing material:PBT
P+F Pepperl Fuchs Sensor NCN50-FP-A2-P1-V1
People who bought this item also viewed
IFM Sensor KI5301
Schneider Sensor XS1D18PA140
Contrinex Sensor DW-AS-509-M8-393
TAKEX Sensor UM-T100S
TAKEX Sensor GTR3RSPN
Honeywell Flame Detector IRD820
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TTO Oil Seal TC 32*56*12
SMC Solenoid Valve SY5440-5LOU-Q
STNC Air Cylinder TGLJ-32X100
Recent related posts
-
08/19/2020
Why do industrial chillers need to replace high-quality antifreeze regularly
When the industrial chiller is running, there are high requirements for the use of antifreeze. Ordinary equipment cannot use high concentration antifreeze. If the concentration of antifreeze is high, it takes a long time to warm up before operating the equipment.
-
06/22/2020
What to do if the refrigerator does not cool in winter
1.If it is because of the weather, you need to change the refrigerator to another location. 2. When used in winter, you can turn on a compensation switch in the refrigerator. 3. It is necessary to check whether the compressor is damaged. 4. If the modulation gear is incorrect, you can adjust the gear higher. 5. If the refrigerant is not enough, the problem of non-refrigeration can be solved after the fluorine content is added.
-
07/23/2020
9 usage details that affect the life of air conditioners
1. Clean the air filter frequently. Usually clean once every 2-3 weeks. The steps are: remove the panel; pull out the air filter; clean the air filter. Rinse the air filter under the tap. Since the filter is made of plastic frame and polyester silk, it should not be cleaned with hot water above 40℃ to prevent shrinkage and deformation.
-
02/17/2021
How about the cooling effect of the air-conditioning fan
Air-conditioning fans are becoming more and more popular in summer. Of course, the price of air-conditioning fans is cheaper than air-conditioning. Of course, the cooling effect is not comparable to that of air-conditioning. So what about the cooling effect of air-conditioning fans? This is also a problem that everyone is more concerned about. In addition, the principle of the air-conditioning fan is also what you want to know. Let's take a look at the cooling effect of the air-conditioning fan with the editor, for your reference.
-
07/30/2020
About inverter air conditioner fault repair skills
Today I will share with you the maintenance ideas and cases about the failure of the inverter air conditioner that does not heat but can cool. If you like, you can like it and collect it, thank you!!!<br></br>
-
06/13/2020
New Live with Cargo Race Track-How does Cold Chain Logistics build a Minsheng Bridge
New Live with Cargo Race Track-How does Cold Chain Logistics build a Minsheng Bridge Sudden epidemic, making fresh electricity providers bursting again, cold chain logistics also ushered in the explosive growth.
-
03/10/2021
The main circuit fuse fusing is a common fault of SCR servo driver. The causes of fuse fusing are as follows
The "phase sequence" of power incoming line is incorrect. Due to the synchronization problem between the trigger pulse and the main circuit of SCR servo driver, there are strict requirements on the "phase sequence" of the input power supply. If the "phase sequence" is not correct, connecting the power supply may immediately cause the fuse of the main circuit of the driver to blow.
-
06/13/2020
What cooling methods do you know Come chat!
What cooling methods do you know? Come chat! 1. Steam compression refrigeration Principle: In the vapor compression refrigeration cycle system, the compressor sucks low-temperature and low-pressure refrigerant vapor from the evaporator
-
07/28/2023
Heat Pump Making Loud Noise in Cold Weather: Causes and Solutions
When the temperature drops outside, your heat pump becomes an essential part of your home's heating system. While it's common for heat pumps to make some noise during operation, loud or unusual noises can be a cause for concern.
-
06/18/2020
Analysis of the circuit diagram of the two compressors' phase failure protection
Analysis of the circuit diagram of the two compressors' phase failure <br><br> Air compressor phase failure <br><br> circuit In the figure, KP is the electrical contact pressure gauge Ai is the CD4073 AND gate circuit, Az is the ~D4025 NOR gate circuit, and A3 is the CD4071 OR gate circuit. The 7806 three-terminal fixed integrated voltage regulator is used as the control circuit for the DC working power supply. When the AC power fails, the relay KA is released and the motor stops. Circuit diagram of compressor phase failure <br><br><img src="{{media url="wysiwyg/Analysis_of_the_circuit_diagram_of_the_two_compressors_phase_failure_protection.jpg"}}" alt="" />