PCB Relays
Contact arrangement: 2 Form C
Surface-mount availability:SA type
Panasonic Relay TX2SA-4.5V-Z
People who bought this item also viewed
Riken Relay RAB-150N
SIEMENS Relay 3TK2824-1AL20
PARKER Relay SCPSD-400-14-27
JEL Relay S1C-225WDV
TRIAD Transformer F-302U
Schneider Circuit Breaker LV431830
Schneider Contactor LC1D32ED
OBO Surge Protection Device V20-C/3
Raychem Fuse TR250-120T-RB-B-0.5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Kompass Vane Pump VFA1-15F-A2
Schneider Sensor XS1L06NA340S
COSEL Power Supply PBA1000F-7R5-F1
FOTEK Sensor UR-10P-PG
Recent related posts
-
08/27/2020
Compressor overhaul and correct installation matters, super complete and detailed
Content covered by compressor overhaul Compressors generally need to be overhauled after 12,000-26,000 hours of operation. In addition to all the work required for intermediate maintenance,
-
05/07/2022
Working Principle of 5 Kinds of Solenoid Valves?
When the power is on, the electromagnetic coil generates electromagnetic force to lift the closing part from the valve seat and open the valve
-
08/21/2023
Swimming Pool Heat Pump: Definition, Working Principle and Benefits
If you're a pool owner, you know that keeping your pool at the perfect temperature is crucial for a comfortable and enjoyable swimming experience.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/14/2021
Do you know these 10 questions about air conditioning?
Fluorine deficiency: If the air conditioner in your home is an old-fashioned air conditioner that has been used for a long time, it may be because the Freon refrigerant in the air conditioner is gone, and you can continue to use it only by adding Freon. 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧֖ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
06/13/2020
Rotor compressor
The rotor compressor is driven by the engine or the motor (mostly driven by the motor), and the other rotor (also known as the female rotor or the concave rotor) is driven by the oil film formed by the main rotor through oil injection, or by the main roto 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然
-
08/15/2022
What is DC Motor and How Does It Work?
A DC motor (direct current motor) refers to a rotating electrical machine that can convert direct current electrical energy into mechanical energy (DC motor) or convert mechanical energy into direct current electrical energy (DC generator).
-
11/21/2021
Benefits of Rosemount Fieldbus Transmitter
It is reasonable to say that Rosemount fieldbus transmitter series can help customers reduce the overall cost of the system.
-
08/05/2020
Can you judge whether the refrigeration compressor is leaking in 5 steps
Insert the power plug of the air conditioner into the power source, and the air switch will trip immediately! Compressor leakage? Follow the following five steps to confirm the compressor leakage fault.
-
08/23/2022
Choose the Right Electric Valve Actuator
The actuator is an indispensable and important part of automatic control system. Its function is to accept the control signal sent by the controller and change the size of the controlled medium