Family Name | MINAS A5 |
Series | MDME Series |
Type | Middle inertia |
Product | Servo Motor |
Voltage (V) | 400 |
Rated output (W) | 400 |
Rated rotational speed (r/min) | 2000 |
Rated rotational Max. speed (r/min) | 3000 |
Rated torque (N ⋅ m) | 1.91 |
Momentary Max. peak torque (N ⋅ m) | 5.73 |
Moment of inertia of rotor [x10-4 kg ⋅ m²] | 1.61 |
Recommended moment of inertia ratio of the load and the rotor | 10 times or less |
Flange sq. dimension (mm) | 100 mm sq. |
Motor encoder connector | Connector |
Rotary encoder | Specifications |
Shaft | Round |
Holding brake | without |
Oil seal | with |
Enclosure | IP67 |
Panasonic Servo Motor MDME044S1C
People who bought this item also viewed
Panasonic Servo Motor MSME022G1C
Panasonic Servo Motor MDM152A4C
Panasonic Servo Motor MUMA042P1S
Panasonic Servo Motor MDMA102A1H
Panasonic Servo Motor MDME102G1H
Panasonic Servo Motor MHME402GCG
SIEMENS Servo Motor 1FK7022-5AK71-1HG0
Sanyo Denki Servo Motor R2AA06040FXH11M
Fuji Servo Motor GYH102C6-TC2
Allen Bradley Servo Drive 2094-BM02-M
ATOS Servo Valve E-RI-TEB-N-NP-01H 10
Honeywell Actuator N2024-SW2
Omron PLC CQM1-CIF11
MITSUBISHI Spindle Amplifier MDS-A-SPJ-04
SEMIKRON IGBT Module SK100GH12T4T
HOPPECKE Battery OPzV-250AH
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TYCO Relay IM42DGR
AirTAC Air Cylinder TCM32X275S
Festo Air Cylinder DGC-32-250-KF-YSRW-A
PIZZATO Switch FX 693-E3D2
Panasonic Servo Drive MSDA015D1A
MAC Solenoid Valve 45A-N00-DAAA-1BA
Schneider Sensor XS530BLPAM12
ADDA Fan AD07012HB159300
Recent related posts
-
08/20/2020
Tips on Air Conditioning Extension Tube
Many friends know that if the air conditioner is installed, there will be an extra charge, and this fee does not seem to be low, but you don’t know that after the air conditioner connecting pipe is extended to a certain distance,
-
07/02/2020
okmarts.com platform compressor technology experts tell you why the air conditioner can be cooled
okmarts.com platform compressor technology experts tell you why the air conditioner can be cooled In the summer, I believe that many people's feelings must be hot, scorching heat, sweating, etc. At this time, air conditioning is naturally essential equipment. If the air conditioner in your home is not cooling, then the air conditioner becomes a decoration.
-
06/14/2020
What to do if the refrigeration compressor is damaged
What to do if the refrigeration compressor is damaged After the refrigeration compressor in the refrigeration system is damaged, the new compressor cannot be replaced directly because there may be some incentives for the refrigeration compressor to be da 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령
-
08/06/2020
Precautions for drainage problems in cold storage design
In the era of modern technology development, the combination of cold storage design and automatic control is not too much. Now it is mainly concerned with the standardization of cold storage design.
-
06/19/2023
How Much is a Compressor for a Fridge?
When your refrigerator stops working or is not cooling properly, it can be a cause of concern.
-
08/27/2021
Why a Compressor is Used in the Refrigeration System
Why are refrigeration compressors used in small and medium-sized refrigeration systems? The compressor is the core equipment in the refrigeration system
-
06/14/2020
In doing so, there is no need to worry about reversing the refrigeration compressor! (technology sharing)
In doing so, there is no need to worry about reversing the refrigeration compressor! (technology sharing) When the refrigeration compressor unit is in normal operation, it should also be checked accordingly to prevent the refrigeration compressor from re 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
06/14/2020
Broken refrigeration compressor bearings? What can be repaired? Which must be thrown?
Broken refrigeration compressor bearings? What can be repaired? Which must be thrown? How to judge whether the bearing can be used again and the defects of the bearing need to be replaced To determine whether the bearing can be used again, it should be 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱
-
09/05/2020
What is the difference between single screw compressor and twin screw compressor
Single-screw and twin-screw manufacturing process of twin-screw is more complicated than single-screw in terms of structure, and the difference in service life and working efficiency is not very big,
-
09/08/2020
21 problems that should be paid attention to when using air compressor inverter
Improper use of the inverter will not only fail to give full play to its excellent functions, but may also damage the inverter and its equipment, or cause interference, etc. Therefore, the following matters should be noted during use: