Structure: open type with a lever
Application: steam, air
Working pressure: 0.05-1.0 MPa
Yoshitake Safety Valve AL-160L(DN40)
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder TCMJ40X40-20
Honeywell Sensor XCXL10DNC
LG LS PLC Conversion Module G6F-AD2A
HENGSTLER Encoder AC58/0017EF.42SBH
Recent related posts
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
11/24/2021
As 5G is on the Way, Do You Really Understand the Use of HMI?
What is HMI (Human Machine Interface)? This era is smart and full with information. We have already been placed in the age of smart technology and filled with all kinds of new devices and inventions every day.
-
06/29/2020
Introduction of measures for compressor pressure protection
Introduction of measures for compressor pressure protection Measures for compressor pressure protection include the following: 1. Control of suction and exhaust pressure When the compressor is running, due to the system or the compressor itself, the discharge pressure may be too high or the suction pressure may be too low. For this reason, the suction and discharge pressures need to be controlled.
-
06/30/2020
Structural differences between three common compressors
Structural differences between three common compressors The three common structures of compressors are rotor compressors, scroll compressors and piston compressors. The structures of these three compressors are different. It is precisely because of their different structures that different functions exist.
-
06/29/2020
Time node of compressor refrigeration oil replacement
Time node of compressor refrigeration oil replacement 1. The long-term operation of the entire refrigeration system, after the initial maintenance, if there are no special circumstances, the compressor refrigeration oil should be replaced when the refrigeration system working time reaches 10,000-12,000 hours.
-
01/16/2024
Industrial Fans: Advantages, Functions and Differences from Ordinary Fans
Industrial fans are widely used in factory workshops, logistics warehouses, basketball stadiums, stations, dairy farms, etc.
-
07/20/2022
Structure and Working Principle of Diaphragm Pump
Diaphragm pump is a novel mechanical transportation equipment, which can absorb all kinds of corrosive liquids, liquids with particles, and liquids with high viscosity, volatile, flammable and highly toxic.
-
03/15/2022
A Brief Introduction to the Chiller
The chiller, whose full name is the evaporative cooler, is also known as the air cooler, water-cooled air conditioner, industrial air conditioner, energy-saving
-
06/25/2020
Classification of air-conditioning compressors
The air-conditioning compressor plays the role of compressing and driving the refrigerant in the air-conditioning refrigerant circuit. The working circuit is divided into an evaporation area (low pressure area) and a condensation area (high pressure area). The indoor unit and outdoor unit belong to the high-pressure or low-pressure area (depending on the working state), and the compressor is generally installed in the outdoor unit.
-
07/31/2020
The 8 accessory usages that must be mastered when using computer room air conditioners!
The electrical control and air circulation of the computer room air conditioner are independent units. During maintenance and overhaul, the air conditioner does not need to be turned off, and the stable air flow and temperature gradient in the air conditioner room can also be ensured