Product name | DC Fan |
Frame material | Plastics |
Series | San Ace 80 |
Frame size(mm) | Square - 80mm L x 80mm H |
Frame thickness | 25.00mm |
Rated voltage[V] | 24VDC |
Rated current[A] | 0.06 |
Rated input[W] | 1.44 W |
Rated speed[min-1] | 2600 |
Max. airflow[m3/min] | 0.92 m3/min |
Max. airflow[CFM] | 32.5 CFM |
Max. static pressure[Pa] | 28.4 Pa |
Max. static pressure[inchH2O] | 0.114 |
SPL[dB(A)] | 26 dB(A) |
Expected life[h] | 60000/60℃ (90000/40℃) |
Sensor type | With a pulse sensor |
IP rating | - |
PWM control function | No |
Bearing Type | - |
Fan Type | - |
Features | - |
RPM | - |
Termination | - |
Operating Temperature | - |
Approval Agency | - |
Weight | - |
We can also provide the following models
9HV0612C0D001
9GA0805L102
9HV5748C10013
9GV0948E0001
9WL0424E401
9HV1412J00023
9WV1712F1011
9HV0412S9013
9HV5748J2D001
9GA1524D9D011
9HV1405B90013
9HV1524W50013
9GV3648D5D001
9L1424G4001
109BM12M016
9HV1724J002
9HV3648W302
9GV3612F90011
9HV0648G2D001
9HV1224D7D0011
9HV4705B6002
9GA1224F2013
9GA0924W102
9GA0412L0D013
9GV1312M90021
9GV1505D5D0011
9CRL0648J302
9GV0312S3013
9GA1705D10011
9HV1248D9D001
9GA4724W0001
9GA1405D0D013
9GV2012J1023
9GV0312E70021
9GA1724H902
9WP1748M5D01
9WL1748F402
9GV0324C6D01
9HV1448W1011
9GA4748M7D001
9GA0512K00011
9GV1748F2021
9WL0612D1011
9HV2048L70011
9GV2024L60013
9HV1548A7D001
9HV1505L0013
9GA0524H40013
9HV0305D20011
9HV1505D4021
109BMC24G027
9GA0912K2023
9HV2048J90021
9WV0912F6021
9HV3612B9D01
9HV1348J1001
9GA2012E5002
9GA1205H3013
9WP0448J1D011
9GA5748D7002
9GA1205B902
9HV1512H1D01
9GV0612H2002
9GA0312F60021
9HV1705F1D0011
9WP1248J1D0011
9CRL0912P5SD01
9GV1712D5D001
9GA1705D201
9WV0848G4D0011
9GA0405C1D013
9GA0605M6D013
9GV4724H7D013
9GA2048S5D001
109BM12S012
9CRH5748K002
9HV1712K9D011
9HV1312S60013
9HV3612B702
9GA4705K4D013
9GV0605W1011
9GA1424J0021
9HV1412G7001
9GA1712G90013
9GA1305E7D0011
9GA1524S60013
9HV5724F5013
9HV1524F9D013
9GA0424E6021
9HV0505S202
9GA1324D1D0011
For more information,please contact us freely
Sanyo Denki Fan 109R0824F401
People who bought this item also viewed
Ziehl Abegg Fan FN080-ZIQ-GL.V7P3
ROYAL Fan UT275DW-TP
Sanyo Denki Fan 9GV1212P1G01
Sanyo Denki Fan 9SG1224G1D01
Sanyo Denki Fan 9WF0424F6D04
Sanyo Denki Fan 9GV1512P5M031
Sanyo Denki Fan 9HV1248P1G008
Ebmpapst Fan S4D500-AE01-14
KAKU Fan KA1606HA1BMT
Nidec Fan W40S12BMF5-01Z90
Delta Power Supply DPS-1200FB A
Siemens Transformer BV7103
Moeller Contactor DIL3M80
PARKER Filter 932666Q
EMERSON Sight Glass AMI-1MM2
Beckhoff Module KS3122
OEG Relay OMI-SS-212L
MUNDORF Capacitor 450V 8.2UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Banner Light Curtain SLSP14-300Q8
Keyence Sensor IL-065
Kompass Vane Pump VQ225-52-52-FR
HONGFA Relay HF32FV-G-12-HTF
SHAKO Air Cylinder JCDA50B50
Repair Kit for Kubota V3800
DID Industrial Chain DID SCR-0409 SV
Recent related posts
-
09/04/2020
Have you heard of the 6S management of the compressor station on-site
For compressor users, on-site management is one of the daily management content of each enterprise.
-
06/14/2020
The main features of screw compressors What are the advantages of screw air compressors
Power balance is good. The screw compressor has no unbalanced inertial force, the machine can work smoothly at high speed, and it can be operated without foundation. It is particularly suitable for use as a mobile compressor, with small size, light weight ﰸ2 䀀 ᅵ皥
-
07/01/2020
How to check the compressor body for cracks
How to check the compressor body for cracks In winter, it is relatively common for compressors to crack. I believe many people have ideas to prevent this kind of problem. In fact, it is not impossible, as long as we conduct a detailed inspection of the compressor body during normal maintenance, this problem can be avoided.
-
07/27/2020
The refrigerator compressor keeps beeping after cleaning, but it is not cooling. What's the problem?
he compressor keeps ringing, so it keeps working. There is no intermittent start and stop sound, which means it has been working hard to refrigerate, but now there is no refrigeration output.
-
03/18/2024
What Is a Closed Loop System (Servo System / Servomechanism)?
As shown in the figures above, the closed-loop control system has a feedback device to feedback the position of the servo motor, but the open-loop control system does not.
-
06/14/2020
Cause Analysis of Refrigeration Compressor
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal,
-
06/14/2020
Working principle of rotary vane compressor
Working principle of rotary vane compressor
-
08/14/2020
Selection requirements for cold storage refrigerants
The nature of the refrigerant will directly affect the type, structure, size and operating characteristics of the refrigerator, as well as the form, equipment structure, and economic and technical performance of the refrigeration cycle.
-
05/09/2022
Common Faults and Solutions of Solenoid Valve?
Detection method: First, measure its make-break with a multimeter. If the resistance value approaches zero or infinity, it indicates that the coil is short circuited or open circuited.
-
07/27/2022
Working Principle of a Vane Pump
During a rotation cycle, the volume between adjacent vanes changes because of the rotor’s eccentric mounting position.