Series | SUPER V |
Outer diameter of motor | 87.5 mm |
Rated output | 400W |
We can also provide the following models
P10B10050BCAA0
R2AA08008DCP00
R2AA22075LBH00
V520BT-011E16
KA511JC6
V550-011EL8
R2AA13075LCH00
R2GAD102RFBC00M
P60B13350HBN00
P50B08075DXM00
R1CA13180MXH03
R1CA28180RXH03
R2EA06040LCP00
R1AA10250HBH00M
R2EA08050DBP00MA
R2CA10150RXH03M
R2CA32150BCH03
P60B22050MBN00E
R1GA02D20DXC03
R2AA04120DXP000A
R2AA04020LXH01M
KA804JS6
R2CA18100BXR00
R2GA0202RDCR03
R1GA04D30BCR50
V540B-011EL8
Q1AA04010DBF00M
R2AA04200LCH01MA
Q2AA13100HBD00
R1GAD1005DXR50
P60B1325kHBM00
R1GAD1003HCH03
R2GA02D20LCR50M
R2AA04010FBH00MA
R1GAD1D20MCH50M
P60B18750BXN00E
R2CA28150MXH03M
R1GA06005HXH50
R2GA06D20DXR03
R1GA02005RBR50M
For more information,please contact us freely
Sanyo Denki Servo Motor V840T-012
People who bought this item also viewed
XINJE Servo Motor MS-130ST-M10015B-21P5
Panasonic Servo Motor MSMD042P1U
Sanyo Denki Servo Motor V850T-012
Sanyo Denki Servo Motor R2AA06040FXH00W
Sanyo Denki Servo Motor R2AA06040FXH11M
Sanyo Denki Servo Motor SM80T-251
Mitsubishi Servo Motor HA-FF38-UE-S1
Panasonic Servo Motor MSM022P1E
XINJE Servo Motor MS-180ST-M19015B-43P0
Inovance Servo Motor ISMH4-40B30CB-U234Z
Allen Bradley Servo Drive 1394-SJT05-C
HITACHI VFD Frequency Converter SJ300-015LF
Honeywell Actuator M9484F1049
Hossoni Power Supply HB17300SL5A
JSCC Speed Reducer 70GK18H
MITSUBISHI Spindle Amplifier MDS-A-SPJ-22
Schneider Controller Module LUFC00
SANYO Battery 12N-1600SCB
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Sensor DAME-MVC-420
P+F Pepperl Fuchs Sensor NBN50-L2K-E2-V1
Panasonic Servo Motor MHME104S1D
UNIVER Solenoid Valve E-0722
Recent related posts
-
06/23/2020
The air conditioner suddenly stopped cooling.
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
-
08/03/2020
The difference between refrigerant R404A and R507
Refrigerant is also called refrigeration working fluid, which is the blood of refrigeration system. It is called refrigerant, refrigerant or Freon in many places.
-
07/26/2020
Common faults and troubleshooting methods of refrigeration compressors
The compressor is the "heart" of the refrigeration system. The compressor sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and then discharges the high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle to realize the refrigeration cycle. The editor summarizes the common faults and troubleshooting methods of the compressor to help you better maintain the compressor.
-
07/27/2020
Most high and low temperature test chambers choose Taikang compressors
The refrigeration compressor of the high and low temperature test chamber adopts the original French Tecumseh compressor. Its working principle is to suck in low temperature and low pressure refrigerant gas from the suction pipe, drive the piston to compress it through the operation of the motor
-
07/18/2020
The role of precision chillers in various industries
Piston refrigeration compressor liquid hammer process and reasons for liquid hammer 1. Introduction The phenomenon that liquid refrigerant and/or lubricating oil is sucked into the compressor cylinder with the gas and damaged the suction valve plate
-
12/27/2022
How do Programmable Logic Controllers Work?
When a programmable logic controller (PLC) is put into operation, its working process is generally divided into three steps, namely input scan, executing program(s), and output scan.
-
09/10/2020
Working principle of scroll compressor
Features of scroll refrigeration compressor 1. The pressure difference between two adjacent chambers is small, and the leakage of gas is small.
-
06/25/2020
What are the three tubes of the refrigerator compressor
What are the three tubes of the refrigerator compressor 1. The general refrigerator compressor has three pipe ports;
-
01/14/2021
2p air-conditioning compressor how much money
2p air-conditioning compressor how much money Whether at work or in life, everyone has the feeling that the development of science and technology is getting faster and faster and more and more economically powerful. It is also because of the development 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ծ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
02/18/2020
Refrigerator does not cool repair price
The price of refrigerator repair is not familiar to everyone. In summer, it is the most frequently used period of refrigerators, and it is also the period when refrigerators are most prone to failure. The most prone to failures in refrigerators are freezing and non-refrigeration inside the refrigerator. The editor looks at the repair price of the refrigerator without refrigeration and the reasons for the refrigerator without refrigeration, for your reference.<img src="{{media url="magefan_blog/Refrigerator_does_not_cool_repair_price.jpg"}}" alt="" />