Operating Voltage:48-280 VA
Rated Load Current:125 Amps
Operating Voltage (47-440Hz) [Vrms] 24-280
Transient Overvoltage [Vpk] 600
Maximum Off-State Leakage Current @ Rated Voltage[mArms] 1
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] 500
Maximum Load Current [Arms] 10
Minimum Load Current [Arms] 150
Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 380/400
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.3
Thermal Resistance Junction to Case (Rjc) [°C/W] 0.35
Maximum 1/2 Cycle I² t for Fusing (50/60Hz, 1/2 cycle) [A² sec] 720/660
Minimum Power Factor (with Maximum Load) 0.5
HP Rating UL 508/IEC60947 [-10 Option][HP (KW)]: 120 VAC 0.5 (0.37)
Overvoltage Protection:Included
Sensata-Crydom Relay CWU48125P
People who bought this item also viewed
Riken Relay RAB-150N
TOGAMI Relay TJ-125-3F
PARKER Relay SCPSD-400-14-27
Tamura Transformer 3FL34-75
Mitsubishi Circuit Breaker NF125-SXV 4P
Schneider Contactor LC1D12T7
Littelfuse Fuse 0287030.PXCN
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Shinko Temperature Controller PCB1S10-33
BOURNS Encoder ECW0J-B24-EC0006
TTO Oil Seal SB 45*65*9
Recent related posts
-
08/20/2020
Trouble phenomenon the air conditioner is not cooling, the outdoor unit starts and stops frequently
When the air conditioner is frequently used in summer, many friends will encounter this problem, that is, the outdoor unit of the air conditioner frequently starts and stops, but the indoor unit is not cooled.
-
08/17/2020
Detecting and repairing methods for problems in shell and tube condensers
Since the central air conditioner is a kind of refrigeration equipment, it must be equipped with a condenser, and most of them are shell and tube condensers. When the device has been used for a long time, some inconveniences may occur.
-
03/19/2024
Servo Motor vs. Stepper Motor: Unraveling the Differences and Choosing the Right Fit
In the realm of automation and precision control, the choice between servo motors and stepper motors plays a pivotal role in determining the efficiency and accuracy of various systems.
-
06/14/2020
The main features of screw compressors What are the advantages of screw air compressors
Power balance is good. The screw compressor has no unbalanced inertial force, the machine can work smoothly at high speed, and it can be operated without foundation. It is particularly suitable for use as a mobile compressor, with small size, light weight ﰸ2 䀀 ᅵ皥
-
07/07/2020
The aging of air conditioners caused fires. The heat is coming.
The aging of air conditioners caused fires. The heat is coming. Are your home appliances overaged? The police reminded: As summer is approaching, we should pay attention to the service life, quality and installation environment of household appliances. The wires of many electrical appliances are mainly insulated by a layer of rubber on the outside.
-
02/03/2023
6 Types of Commonly Used Gear Reducers
Gear reducers are generally used for transmission equipment with low speed and high torque. The ratio of the numbers of teeth of the big and small gears equals the transmission ratio.
-
01/26/2024
Computer Room Air Conditioning: Work Principle, Characteristics and Technical Requirements, Benefits
Computer room air conditioners (CRACs), to put it simply, are air conditioners dedicated to computer rooms.
-
08/26/2020
The development history of scroll refrigeration compressors
1. In 1905, Frenchman Leon Creux proposed the working principle of scroll machinery and applied for a US patent.
-
09/16/2020
Air compressor sharing air storage method
When multiple pneumatic tools are used at the same time, multiple air compressors need to be used for combined air supply. In order to reduce the pulsation of the air supply pressure and prevent the air pressure from falling instantaneously when multiple pneumatic tools are started at the same time on the working surface
-
06/25/2020
Classification of air-conditioning compressors
The air-conditioning compressor plays the role of compressing and driving the refrigerant in the air-conditioning refrigerant circuit. The working circuit is divided into an evaporation area (low pressure area) and a condensation area (high pressure area). The indoor unit and outdoor unit belong to the high-pressure or low-pressure area (depending on the working state), and the compressor is generally installed in the outdoor unit.