Shinco Air Conditioner KY-26F2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
LEEMIN Filter LH0500R030BNHC
Schneider Transmitter RMTK80BD
EVAC Mechanical Seal 109-48
COSEL Power Supply FCA200F-24-C
AirTAC Air Cylinder SC250X30S
Yaskawa Encoder UTOPH-200WC
Recent related posts
-
08/13/2020
Water-cooled chillers need to be cautious when choosing cooling towers
In many special use environments, companies need to apply water-cooled chillers. Because water-cooled chillers need the help of cooling towers during operation, they need to follow the
-
09/06/2020
Application of Piston Rod Settlement Monitoring System in Reciprocating Compressor
1. Introduction A petrochemical plant imported a reciprocating compressor from abroad, the model is: B254-4118N3.3, 4 rows of symmetrical balanced type, the import and export parameters are: 135kPa (A)@14℃, 3.4MPa (A)@35℃, rotation speed: 425r/min, stroke: 240mm.
-
07/30/2020
Do you know all about the setting of fire damper in HVAC system?
In the HVAC design, there are many types of valves for fire prevention and smoke exhaust, and the valve settings are different for different applications.
-
09/10/2020
Discussion on Reasons and Protection of Air Compressor Motor Damage
Air compressor is abbreviated as air compressor. As a general-purpose mechanical equipment, it is widely used in the field of industrial and agricultural production. The problem is that the motor (three-phase asynchronous motor) as the power equipment of the air compressor generally has a higher failure rate than other motors.
-
07/30/2020
Causes and troubleshooting of industrial chillers
1. High condensing pressure (higher than the specified value) failure causes and remedies:<br></br> ①There is non-condensable gas in the system: release non-condensable gas.
-
07/30/2020
How to detect inferior refrigerants What's the harm
Inferior refrigerants will affect the performance and stability of the system, and even more serious will cause damage to system components and compressors. The following methods can be used to distinguish whether it is a low-quality refrigerant:<br></br
-
06/25/2020
Is Hitachi air-conditioning compressor Toshiba brand
"I obviously bought a Hitachi air conditioner. It was discovered that the air conditioner used a Toshiba compressor during maintenance." A few days ago, some media reported this complaint about Hitachi air conditioners. Therefore, many consumers questioned the difference between the case and the internal machine brand: the purchase clearly identified a certain brand, why did you change the brand of the contents inside without telling it? Is there any difference between the products of the two brands? What if the after-sales service is not guaranteed?
-
08/14/2020
What is the hazard of high temperature to compressor motor and lubricating oil
The heat generated by the compressor during normal operation should not cause overheating. Normal motor heating, compression heat and friction heat have been carefully considered when designing the compressor,
-
07/29/2020
Common reasons and maintenance methods for the fan not rotating outside the air conditioner
Common reasons and maintenance methods for the fan not rotating outside the air conditioner After the air conditioner is used for a long time, or the installation process is not in place,
-
11/09/2021
PLC (Programmable Logic Controllers) and HMI (Human-Machine Interface) for Intelligent Factory
The development of "intelligent factory" has put forward a new direction for manufacturers. It is necessary for manufacturers to master the production and marketing process clearly