Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 12.5 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 9...12.5 A |
Suitable for induction motors with P | 5.5 kW |
Instantaneous overcurrent releases | 163 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.426 kg |
Circuit breaker size S0 for motor protection CLASS 10 with overload
relay function A-release 9...12.5 A Short-circuit release 163 A Screw
terminal Standard switching capacity !!! Phased-out product !!!
Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2111-
1KA10<<
product brand name SIRIUS
product designation circuit breaker
design of the product For motor protection with relay overload functionality
General technical data
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 9.25 W
at AC in hot operating state per pole 3.1 W
surge voltage resistance rated value 6 000 V
protection class IP
on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
continuous current rated value 12.5 A
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
9 ... 12.5 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating current
at AC-3
at 400 V rated value 12.5 A
operating power
at AC-3
at 400 V rated value 5.5 kW
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 42 kA
at AC at 690 V rated value 6 kA
Short-circuit protection
design of the overcurrent release and short-circuit
release
thermomagnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 50022
height 97 mm
width 45 mm
depth 96 mm
required spacing
with side-by-side mounting
backwards 0 mm
at the side 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals
for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
front side
type of connectable conductor cross-sections
for main contacts
solid 2x (1 ... 2.5 mm?), 2x (2.5 ... 6 mm?)
stranded 2x (1 ... 2.5 mm?), 2x (2.5 ... 6 mm?)
finely stranded with core end processing 2x (1 ... 2.5 mm?), 2x (2.5 ... 6 mm?)
at AWG conductors for main contacts 2x (14 ... 10)
Siemens Circuit Breaker 3RV1121-1KA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1031-4AB10
Siemens Circuit Breaker 3RV2031-4WA10
Siemens Circuit Breaker 3WN6361-0GV58-0AK1
Siemens Circuit Breaker 3RV1021-1KA10
ABB Circuit Breaker 10113715
Terasaki Circuit Breaker ZS50-NF
Siemens Circuit Breaker 3RV2011-1AA20
Siemens Circuit Breaker 3RV1011-0BA10
Delixi Transformer CDDZ-2000VA
Shilin Contactor S-P30T 35
OBO Surge Protection Device MDP-4 D-5-Ex
Schurter Fuse 0090.0020
TYCO Relay 7012AC
IRC Resistor 20190907 1W 658R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TYCO Relay KUP93-14D13-24
Rockwell Allen-Bradley AB VFD 20G14NC085AA0NNNNN
ZAGA Worm Gear Reducer HPF60-3
Recent related posts
-
07/22/2020
The working principle of cooling and heating of air conditioning
In addition to the cooling function, the heating and cooling air conditioner also has the heating function. The biggest difference from a single-cooling air conditioner is that an electromagnetic four-way reversing valve is installed in the heating and cooling air conditioner.
-
02/09/2022
7 Reasons Why an Air Compressor is Overheating
As hot summer is coming, air compressor maintenance workers will also usher in the busiest season of the year.
-
03/12/2021
Four control modes of servo drive
1.Feedback compensation open loop control. The accuracy of open-loop system is low, because the step error , start stop error and mechanical system error of servo driver will directly affect the positioning accuracy. This system has the advantages of both open-loop and closed-loop, that is, it has the stability of open-loop and the accuracy of closed-loop.
-
08/06/2020
How to maintain the lubrication system of the chiller
In the operation system of the chiller, more attention is paid to the refrigerant circulation system, the chilled water circulation system and the electrical control system of the refrigerator. The lubrication system is often overlooked. As everyone knows, this system is also very important to the chiller.
-
08/11/2020
Pay attention to these details. The air energy heat pump can be used for more than 10 years.
In a few months, the northern heating season will officially begin. In addition to central heating, this year's "coal-to-electricity conversion" has also received much attention.
-
01/13/2021
What is the reason why Mitsubishi air conditioner does not start
What is the reason why Mitsubishi air conditioner does not start Mitsubishi air conditioners have been trusted by consumers for their high quality for many years, but Mitsubishi air conditioners will also have some failures after a long time of use. Amon 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦
-
08/25/2020
Mitsubishi inverter air conditioner basic principle training
1. The difference between inverter air conditioner and fixed frequency air conditioner <br></br> 1. Different compressors
-
06/14/2020
Introduction of refrigeration compressor structure and working principle
The role of refrigeration compressors in the system In order to be able to continuously cool, the compressor needs to suck the vaporized low-pressure vapor from the evaporator and work on it, compress it into high-pressure superheated vapor, and then d 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Բ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
01/17/2023
How does Variable Valve Timing Work?
The valve timing system of a traditional engine is a mechanical system in which the valve timing (i.e., valve opening and closing) remains unchanged.
-
06/14/2020
What are the types of refrigeration compressors Introduction of refrigeration compression types【Detailed explanation】
Speaking of air conditioning, each of us is no stranger, especially in the hot summer, I am afraid that without air conditioning, we don’t even know how to live. But when it comes to refrigeration compressors, I am afraid that many consumers are not parti 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ