Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.16 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.11...0.16 A |
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.11...0.16 A N-release 2.1 A screw terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 ... +60 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
0.11 ... 0.16 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 0.16 A
operating current
at AC-3
at 400 V rated value 0.16 A
operating power
at AC-3
at 230 V rated value 20 W
at 400 V rated value 40 W
at 500 V rated value 60 W
at 690 V rated value 60 W
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 2.1 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.16 A
at 600 V rated value 0.16 A
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97 mm
width 45 mm
depth 97 mm
required spacing
for grounded parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
for live parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
Top and bottom
type of connectable conductor cross-sections
for main contacts
single or multi-stranded 2x (0,75 ... 2,5 mm?), 2x 4 mm?
finely stranded with core end processing 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?)
at AWG conductors for main contacts 2x (18 ... 14), 2x 12
tightening torque
for main contacts with screw-type terminals 0.8 ... 1.2 N.m
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Pozidriv 2
design of the thread of the connection screw
for main contacts M3
Safety related data
B10 value
with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
with low demand rate acc. to SN 31920 50 %
with high demand rate acc. to SN 31920 50 %
failure rate FIT
with low demand rate acc. to SN 31920 50 FIT
T1 value for proof test interval or service life acc. to
IEC 61508
10 y
display version
for switching status Handle
Siemens Circuit Breaker 3RV2011-0AA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1011-0DA15
Siemens Circuit Breaker 3RV1041-4KA15
Siemens Circuit Breaker 3RV1011-0EA10
Siemens Circuit Breaker 3RV1011-0BA15
Siemens Circuit Breaker 3RV1011-0CA15
Schneider Circuit Breaker LV510337
Mitsubishi Circuit Breaker NF100-SS
COOPER Transformer CTX01-13804
Eaton Contactor DILM12-10(400V50HZ
Ferraz Shawmut Fuse PC71UD13C200PA
TYCO Relay V23154D 531B117
VISHAY Resistor RTO050F4R700JTE1
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Delta Fan EFB0812HHB
THK Linear Guideway SHS25V2SS+1120L
DHF Tool for Metal Cutting UME0162
Recent related posts
-
11/26/2021
Why DC 4~20mA is Chosen for Signal Transmission of Transmitters?
In industry, it is necessary to measure all kinds of electric and non electric parameters, such as current, power, temperature, pressure, speed and angle, etc.
-
10/12/2023
How Long Does It Take to Make Ice Cubes? Answers to All Your Ice-Making Questions
Ice cubes are a convenient way to keep drinks cold, especially during the hot summer months. They are also used in cocktails, smoothies, and many other recipes. However, have you ever wondered how long it takes to make ice cubes?
-
11/16/2022
How to Fix an Industrial Fan?
Industrial fans can effectively control the air circulation in industrial production workshops. However, industrial fans can also fail due to improper use and prolonged use.
-
12/22/2023
AC Fan Turns on and off Repeatedly: 6 Causes and Solutions
Your air conditioning system is designed to provide comfort by maintaining a consistent temperature in your home.
-
08/11/2020
How to solve various problems such as water leakage, noise, and excessive fluorine leakage of air conditioners
When the air conditioner is in use, there are problems such as water leakage, electric leakage, insufficient cooling and heating, excessive noise, etc., which makes the friends feel particularly heartbroken. Buying an air conditioner to solve this problem and that problem is a headache.
-
08/20/2020
Introduction and characteristics of several throttling devices in refrigeration equipment
Among the four major components in the refrigeration system, the throttling device is one, and its function makes it have its own role.
-
09/03/2020
German dairy giant highly praises Ultima compressor
ULTIMA new generation innovative oil-free compressor German dairy giant highly praises Ultima compressor Ultima works perfectly, a compressor that satisfies all your fantasies
-
06/29/2020
How to calculate the number of Copeland compressors
How to calculate the number of Copeland compressors Copeland compressors are divided into L, C, 3S, 4S, and 6S series air-cooled compression and condensation units, which can be used as the main components of various refrigeration devices. The refrigerant can obtain various temperatures required for the preservation of fruits and vegetables, quick freezing of food or refrigeration. How to calculate the number of Copeland compressors?
-
03/11/2022
Is It Necessary to Replace Your Refrigerator Compressor?
The compressor is like the heart of humans, which plays a vital role in the refrigerator. A compressor is key to improve the performance of your refrigerator.
-
07/02/2020
The compressor lacks oil, so the harm is so great!
The compressor lacks oil, so the harm is so great! Compressors are complex machines that operate at high speeds. Ensuring adequate lubrication of moving parts such as compressor crankshafts, bearings, connecting rods, and pistons is the basic requirement for maintaining normal operation of the machine.