Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 36 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 28...36 A |
Circuit breaker size S2 for motor protection, CLASS 10 with overload
relay function A-release 28...36 A N-release 520 A Standard
switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 20?W
at AC in hot operating state per pole 6.7?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
28?...?36?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 36?A
operating current
at AC-3
at 400 V rated value 36?A
operating power
at AC-3
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 30?000?W
operating frequency
at AC-3 maximum 15?1/h
Siemens Circuit Breaker 3RV2131-4PA10
People who bought this item also viewed
AEG Circuit Breaker MBS 25 0.63-1A
Siemens Circuit Breaker 3RV1011-1CA15
Siemens Circuit Breaker 3RV1011-1EA10
Siemens Circuit Breaker 3VA1463-5EE32-0AA0
Siemens Circuit Breaker 3VL7712-2SB36-0AA0
Fuji Circuit Breaker CP30FM-1P010
GE Circuit Breaker SFKOG 1.6-2.5A
Schneider Circuit Breaker LV516332
Siemens Circuit Breaker 3RV1021-4BA15
TRIAD Transformer FS10-3600
Schneider Contactor LC2K0610M7
CITEL Surge Protection Device DS41S-280
Fuji Fuse BLA030
OMRON Relay MK3P5-S 6VDC
Panasonic Resistor EXB-Q16P472J
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HENGSTLER Encoder RI58-D/1250AF.42RD
Nidec Fan L34908-58
TTO Oil Seal TB 96*114*12
SIEMENS Actuator SSP31
Recent related posts
-
06/20/2020
Common fault phenomena, causes and elimination methods of piston compressors
Common fault phenomena, causes and elimination methods of piston compressors Common faults of piston compressor (1) Phenomenon: the compressor cannot start Reasons: 1. Electrical circuit failure; 2. High and medium voltage relay and oil pressure relay are disconnected.<img src="{{media url="Common_fault_phenomena_causes_and_elimination_methods_of_piston_compressors.jpg"}}" alt="" />
-
09/21/2020
Noise Control of Ash Removal Air Compressor Room in Thermal Power Plant
The 240 mm clay bricks are closed to eliminate the influence of direct sound on the outside world. The steel window on the other side of the workshop is fixed (not open), and a layer of airtight and fixed sound insulation windows is added on the outside. The distance between the two windows is 100 mm, the sound insulation window uses 8 mm thick glass.
-
03/06/2023
Types of Cylinder Seals and Factors Affecting Sealing Performance
Cylinder sealing is an important parameter to characterize the technical condition of engine. Cylinder sealing is related to the technical condition of cylinder block, cylinder head, cylinder gasket, piston, piston ring, inlet and exhaust valves and other parts.
-
04/11/2022
What Does an Expansion Valve Do?
Expansion valve is an important part of refrigeration system, which is generally installed between liquid storage tank and evaporator.
-
06/14/2020
Refrigeration compressor motor burnout detection and maintenance methods, quickly collect it!
Refrigeration compressor motor burnout detection and maintenance methods, quickly collect it! What are the methods of detection and maintenance of refrigeration compressor motor burnout? Do your friends know? Let's get to know more with the coldest bacte 器2 䀀
-
06/15/2023
Freezer Compressor Hot: Causes and Solutions
A freezer/refrigerator is an essential appliance in most households, used to store food at low temperatures to preserve its freshness and quality.
-
06/20/2020
The main reason for the slow heating of air conditioners
There are several reasons for the slow heating of air conditioners: The dirt of the transpiration device and the condenser is too thick, which will cause air flow blockage, affect the heat declaration, and make the air conditioning heating a big discount. The filter is not cleaned for a long time<img src="{{media url="The_main_reason_for_the_slow_heating_of_air_conditioners.jpg"}}" alt="" />
-
08/17/2020
What are the effects of water quality on water-cooled chillers
If the cooling performance of water-cooled chillers is to be kept in a stable state, very strict requirements on the water source are required. In the daily use of chillers, if the company does not pay enough attention to the quality of the water source
-
01/07/2022
How to Check and Replace Refrigerator Compressor Relay
If your refrigerator has been in use for some time, there may be some faults with the compressor. To troubleshoot the compressor, check whether there is abnormal noise or overheating phenomenon in the relay.
-
09/10/2020
Application of pressure sensor in air compressor control system
Take a single screw air compressor as an example to illustrate the working principle of an air compressor. The working process of a screw air compressor is divided into four processes: suction, sealing and conveying, compression and exhaust.