Type | 3VA1 |
Breaker Type | 3VA Molded Case Circuit Breakers |
Breaker Designation | Thermal magnetic breakers |
Frame Size | 400A |
Rated Current | 400 A |
Interrupting Capacity | 36 kA |
Number of Poles | 3 pole |
Connection Technology | Nut keeper kit |
Regional Specifics | Standard |
circuit breaker 3VA1 IEC frame 400 breaking capacity class S
Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=400A
overload protection Ir=280A...400A short-circuit protection Ii=5...10 x
In nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM240
protection function of the overcurrent release LI
number of poles 3
General technical data
Tension assignée d'isolement Ui 800 V
Max. rated operational voltage Ue with AC 50/60Hz 690 V
Max. rated operational voltage Ue with DC 500 V
power loss W / maximum 92.1 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
30.7 W
mechanical service life (switching cycles) / typical 15 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
6 000
Electrical endurance (switching cycles) / at AC-1 / at
690 V 50/60 Hz
6 000
Neutral conductors / upgradeable/retrofittable No
ground fault monitoring version Without
product function
communication function No
other measurement function No
net weight 3.9 kg
Current
Max. rated operational current of the frame size 400 A
Courant permanent assigné Iu 400 A
operating current
at 40 degrees centigrade 400 A
at 45 degrees centigrade 400 A
at 50 degrees centigrade 400 A
at 55 degrees centigrade 392 A
at 60 degrees centigrade 384 A
at 65 degrees centigrade 376 A
at 70 degrees centigrade 367 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker S
maximum short-circuit current breaking capacity (Icu)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 36 kA
at 500 V 25 kA
at 690 V 7 kA
operational short-circuit current breaking capacity
(Ics)
at 240 V 55 kA
at 415 V 36 kA
at 440 V 36 kA
at 500 V 25 kA
at 690 V 5 kA
short-circuit current making capacity (Icm)
at 240 V 121 kA
at 415 V 76 kA
at 440 V 76 kA
at 500 V 53 kA
at 690 V 10.5 kA
design of short-circuit protection For switching power values in DC networks, see the 3VA molded
case circuit breaker device manual; link to be found under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 280 A
Adjustable response value current / lg min. 400 A
Adjustable response value current / li min. 2 000 A
Adjustable response value current / li max. 4 000 A
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
Mechanical Design
height in 9.8 in
Height 248 mm
width in 5.4 in
Width 138 mm
depth in 4.3 in
depth 110 mm
Connections
arrangement of electrical connectors / for main
current circuit
Front terminal
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
Accessories
product extension / optional / motor drive Yes
Environmental conditions
protection class IP / on the front IP40
ambient temperature
during operation / minimum -25 degrees centigrade
during operation / maximum 70 degrees centigrade
during storage / minimum -40 degrees centigrade
during storage / maximum 80 degrees centigrade
Certificates
reference code / acc. to DIN EN 81346-2 Q
Siemens Circuit Breaker 3VA1340-4EF32-0AA0
People who bought this item also viewed
GE Circuit Breaker SFKOG 1.6-2.5A
Siemens Circuit Breaker 3RV2011-1DA10
Siemens Circuit Breaker 3RV1011-0EA10
Siemens Circuit Breaker 3VL5763-2AE36-0AA0
Terasaki Circuit Breaker XS100NS
Siemens Circuit Breaker 5SY5263-7CC
Danfoss Transformer 052F4034
Nader Contactor NDC2J-20/20
Littelfuse Fuse 0287035.PXCN
HONGFA Relay HF116F-G1-12-1HTF
Yageo Resistor MFR3WSFTE73-3K3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch FD 2002-M2R24
Sanyo Denki Fan 109P0924H2J03
Daikin Air Conditioner FFDP50CA
IFM Sensor IB0006
Recent related posts
-
07/27/2021
7 Ways to Save Energy on Your Air Compressor
As one of the power sources of manufacturing and production enterprises, compressed air requires continuous operation of equipment to ensure the stability of air supply pressure
-
09/06/2020
What are the requirements of modern industry for oil-free air compressors
After the air is mechanically compressed, it becomes compressed air. The equipment used to produce compressed air is usually called an air compressor. Compressed air is an indispensable pneumatic energy source in people's production and life.
-
11/05/2021
10 Methods for VFD Troubleshooting
It is important to learn the helpful methods for VFD troubleshooting. In order to let everyone be capable of solving VFD problems, we have summarized 10 methods here.
-
06/16/2020
The world’s leader in oil-free compressor technology
The world’s leader in oil-free compressor technology Danfoss is the leading manufacturer of oil free compressors and is the pioneer of the Danfoss Turbocor® compressor - the world’s first oil-free magnetic bearing compressor for the HVAC industry.
-
06/28/2020
Which air conditioners are used by Hitachi compressors
Hitachi compressor technology is mature, good quality, reliable performance, is the first compressor used by Gree, Midea, Chigo, Haier and other air-conditioning manufacturers. okmarts.com is an authorized dealer of Hitachi compressors, with complete specifications and sufficient supply, which can meet your purchasing needs at any time.
-
09/14/2020
Technical standards for silent oil-free air compressors
Technical standard for silent oil-free air compressor 1. Subject content and scope of use 1. This standard specifies the terminology, technical requirements, test methods and inspection rules of silent oil-free air compressors.
-
08/02/2021
Mitsubishi Heavy Industries - Haier Vs. Toshiba Commercial Air Conditioners
Because of the acceleration of urbanization, commercial air conditioners have developed rapidly in recent years.
-
07/03/2020
Building & Construction Hold Over 20 % Share in Portable Air Compressor Market 2019 to 2027
LOS ANGELES, United States: QY Research published latest market research report on global Mute Oil Free Air Compressor market 2020 with industry detail study, growth analysis, latest and future trends, leading companies analysis, regional analysis and forecast by 2026.
-
08/16/2020
What is the emergency treatment method for R22 refrigerant leakage
R22 refrigerant has low toxicity, but some of the cracked gas and residual liquid components produced by using it to prepare tetrafluoroethylene are highly toxic, which can cause acute poisoning.
-
06/14/2020
Do summer air-conditioning rooms need air purifiers
Do summer air-conditioning rooms need air purifiers It is high temperature in summer again. Many people have disputes about whether an air purifier is needed in summer.