circuit breaker 3VM1 IEC frame 400 breaking capacity class S
Icu=55kA @ 415V 4-pole, line protection TM220, ATFM, In=400A
overload protection Ir=280A...400A short-circuit protection Ii=10 x In
N conductor unprotected nut keeper kit
Model
product brand name SENTRON
product designation Molded case circuit breaker
Product version Line protection
design of the overcurrent release TM220
protection function of the overcurrent release LI
number of poles 4
General technical data
Tension assignée d'isolement Ui 690 V
Max. rated operational voltage Ue with AC 50/60Hz 500 V
power loss W / maximum 92.1 W
Active power loss / for rated value of the current / at
AC / in hot operating state / per pole
30.7 W
mechanical service life (switching cycles) / typical 8 000
Electrical endurance (switching cycles) / at AC-1 / at
380/415 V 50/60 Hz
6 000
Neutral conductors / upgradeable/retrofittable No
ground-fault monitoring version Without
product function
communication function No
other measurement function No
net weight 5.1 kg
Current
Max. rated operational current of the frame size 400 A
Courant permanent assigné Iu 400 A
operational current
at 40 degrees centigrade 400 A
at 45 degrees centigrade 400 A
at 50 degrees centigrade 400 A
at 55 degrees centigrade 392 A
at 60 degrees centigrade 384 A
at 65 degrees centigrade 376 A
at 70 degrees centigrade 367 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breaker M
breaking capacity maximum short-circuit current (Icu)
at 240 V 85 kA
at 415 V 55 kA
at 440 V 55 kA
at 500 V 36 kA
breaking capacity operating short-circuit current (Ics)
at 240 V 63 kA
at 415 V 41 kA
at 440 V 41 kA
at 500 V 27 kA
short-circuit current making capacity (Icm)
at 240 V 187 kA
at 415 V 121 kA
at 440 V 121 kA
at 500 V 76 kA
design of short-circuit protection For switching capacity values in DC power systems, see the 3VA
Molded Case Circuit Breaker Manual; link available under Service
& Support in the last chapter
Adjustable parameters
Adjustable response value current / lg min. 280 A
Adjustable response value current / lg min. 400 A
Adjustable response value current / li min. 4 000 A
Adjustable response value current / li max. 4 000 A
design of the N-conductor protection Without
Ground fault protection / tripping switchable /
I2t=ON/OFF
No
Siemens Circuit Breaker 3VM1340-5EE42-0AA0
People who bought this item also viewed
Siemens Circuit Breaker 3RV1031-4HA10
Siemens Circuit Breaker 3RV1042-4KB10
Siemens Circuit Breaker 3RV1011-0BA10
Siemens Circuit Breaker 3RV1021-4BA10
Terasaki Circuit Breaker S100-NF
Siemens Circuit Breaker 5SY6316-7CC
TRIAD Transformer VPS12-3400
Eaton Contactor DILM1000/22
Ferraz Shawmut Fuse A130UD70LI100
TWIDEC Relay TC60D25D
EPCOS Resistor B72660M0200K072
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
VAISALA Transmitter GMW80
CIKACHI Switch AEPB-22
PARKER Filter G00587
AirTAC Air Cylinder SULF50X25S
THK Linear Guideway HSR45TA2UU+2406L
Recent related posts
-
06/14/2020
Comparison of semiconductor refrigeration technology and compressor refrigeration technology
Comparison of semiconductor refrigeration technology and compressor refrigeration technology The mechanical compression refrigeration system includes a compressor, a condenser, a filter, a solenoid valve, an expansion valve, an evaporator, a liquid reser ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧
-
01/13/2021
The role of refrigeration compressors, what is the role of refrigeration and air conditioning compressors?
We know whether it’s a freezer or a refrigerator All need a powerful compressor, So that the freezer can run normally.
-
09/14/2020
Explosion-proof human body static eliminator; explosion-proof human body static eliminator, petroleum-specific human body static eliminator
CM-003 touch static elimination ball, its appearance is made of stainless steel tube and stainless steel ball, it is suitable for chemical, metallurgy, military, oil field, fireworks, computer room, high-end hotels, high-end offices and other flammable and explosive places.
-
08/01/2022
What is A Overflow Valve
Overflow valve also called relief valve is a kind of hydraulic pressure control valve, which mainly plays the role of constant pressure overflow, pressure stabilization, system unloading and safety protection in hydraulic equipment.
-
08/23/2020
Why is it forbidden to use the refrigerator
We all know that with the continuous improvement of people’s material living standards, every household now has a refrigerator. The refrigerator is very useful in the home, especially in summer.
-
08/26/2020
The scroll refrigeration compressor is a new type of refrigeration compressor that has only been put into practical use in the past ten years.
The scroll refrigeration compressor is a new type of refrigeration compressor that has only been put into practical use in the past ten years. It is the most advanced compressor at present, with a refrigeration capacity ranging from 4000W to 40KW.
-
07/12/2023
eciprocating vs. Rotary Compressors: Which is Better for Your HVAC System?
When it comes to selecting the right compressor for your HVAC system, you may find yourself asking the question, "Which is better, reciprocating or rotary compressors?"
-
08/05/2020
Why does the refrigeration compressor produce overheat protection What matters should be paid attention to in the use of overload protector
The working principle and classification of the overload protector. The overload protector of the compressor for air conditioning generally adopts a snap-type bimetallic protector, which consists of a heating wire,
-
12/08/2022
How to Calculate the Service Life for Linear Guideways?
When the linear guideway is under load and moves, the surface of the ball track and the steel ball are constantly subjected to cyclic stress.
-
07/23/2020
The damage of air-conditioning refrigeration compressor and its preventive measures
An 82000DWT bulk carrier of a shipping company broke down on the 7th day after leaving the factory. The crew described that when it started, the air-conditioning refrigeration compressor could not run continuously, and a large current occurred and an alarm was triggered.