Proof pressure: 1.5MPa
Operating temperature: -5 degrees - 50 degrees Remove moisture perfectly from the fluid to prevent freezing when used at 5 degrees or lower.
Temperature rise: 60 degrees Max.
Insulation: JIS C 4003 class B
Power consumption AC:2W DC:3W
Performance(response)time: 0.05s(0.1s)
Performance frequency: Max. 4 cycle/s, Min. 1 cycle/mon.
Applicable cylinder size(for reference): 100-160
KONAN Solenoid Valve 414S303C-ZA5-G6005
People who bought this item also viewed
Honeywell Solenoid Valve VE4015B1004
Bristol Compressor H26A46QDBF
Baumer Sensor IFRM 12N17X1/L
Asco Solenoid Coil 272614-129-D
SMC Proportional Valve ITV2050-31N2CN5
Amico Check Valve 8412 DN32
HAWE Overflow Valve MVCS66F-50
Rexroth Piston Pump A11VLO130DRS10R-NPD12N00
Eaton Vickers Vane Pump 4525V-50A12-1DD22R
KEMET Capacitor T491A475K010AT
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Copeland Compressor EAVA-021E-TAD
KEMET Capacitor C0603C101J5GACTU
Winmost Vane Pump VP-SF-40-B-10-20
Shilin Contactor S-P30T220
Recent related posts
-
07/16/2020
Compressor overheating
The compressor is overheated, causing it to stop shortly after start-up (protector action). Please check whether it is:; Insufficient or excessive refrigerant, please fill the leak and evacuate, add enough refrigerant or release excess refrigerant. The capillary assembly (including the filter) is clogged and the suction temperature rises. Please replace the capillary assembly.
-
08/20/2020
Introduction and characteristics of several throttling devices in refrigeration equipment
Among the four major components in the refrigeration system, the throttling device is one, and its function makes it have its own role.
-
06/20/2020
Common fault phenomena, causes and elimination methods of piston compressors
Common fault phenomena, causes and elimination methods of piston compressors Common faults of piston compressor (1) Phenomenon: the compressor cannot start Reasons: 1. Electrical circuit failure; 2. High and medium voltage relay and oil pressure relay are disconnected.<img src="{{media url="Common_fault_phenomena_causes_and_elimination_methods_of_piston_compressors.jpg"}}" alt="" />
-
08/02/2023
Step-by-Step Guide: How to Fix Heat Pump Freezing Up in Winter
A heat pump is an essential component of your HVAC system that helps regulate indoor temperatures during the winter months. It is designed to work efficiently even in sub-zero temperatures, but sometimes, it may freeze up, causing discomfort and inconvenience.
-
09/16/2020
The development of screw air compressor
Since the advent of screw compressors in 1934, after decades of technological improvement, screw compressors have been widely used, especially in refrigeration.
-
06/14/2020
Air compressors are gradually diversifying. Air compressor industry energy-saving products will become winners
The air compressor industry is a technology-intensive industry with relatively complex production processes and high processing accuracy requirements. From the perspective of demand, air compressors are gradually diversifying. The emergence of general- ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់變ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦
-
06/14/2020
Don't be afraid if the refrigeration system is clogged. Here are retrieval and cleaning methods
Don't be afraid if the refrigeration system is clogged. Here are retrieval and cleaning methods Typical features of clogging 1. The refrigerator or air conditioner does not cool for a long time. 2. The suction pressure drops, and even a vacuum stat ﰸ2 䀀 ᅵ皥 䖒皦
-
12/21/2021
How to Calibrate a Pressure Transmitter Before Use
Pressure transmitter is a kind of commonly used measuring instrument, which can convert the physical parameters such as gas and liquid sensed by load cell into standard signal output.
-
07/15/2022
Common Faults of Gear Pump
Cause: A. the rotation direction is opposite; B. the suction or discharge valve is closed
-
09/08/2022
Brushless Vs Brushed Motor
The following article introduces some differences between brushed motors and brushless motors in terms of working principle and performance, hoping to deepen your understanding of them.