STEIN Welding Wire MEGAFIL A 760 B
People who bought this item also viewed
ROTEN Mechanical Seal 8E5K-22-X
AirTAC Air Cylinder SC40X620
SUNON Fan PSD1204PHB1-A
HIWIN Linear Guideway CGH45CAZAC
AEROVOX Capacitor ALS30A1249DA
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
BGE Industrial Heater BGP1403-05
COSEL Power Supply FAN-MA1-B
Duelund Resistor CAST 22R ±5% 10W
Recent related posts
-
12/27/2023
Troubleshooting the "Air Conditioner Fan Not Spinning But Hums" Issue
When your air conditioner's fan refuses to spin but emits a distinctive hum, it can be a frustrating and perplexing situation.
-
06/20/2020
Working principle of scroll compressor_Characteristics of scroll compressor
Working principle of scroll compressor <img src="{{media url="Working_principle_of_scroll_compressor_Characteristics_of_scroll_compressor.jpg"}}" alt="" /> Scroll compressor is a kind of positive displacement compression compressor, the compression part is composed of movable scroll and static scroll. This includes many structural features that divert the flow of gas through the compressor housing to reduce entrained oil.
-
08/11/2020
Several common causes of compressor bearing damage
There are many important precision parts in first-class compressors, and the most worn part during regular operation is the bearing, so the bearing is one of the parts that need frequent maintenance and replacement.
-
08/28/2020
Analysis of working principle of screw air compressor oil system
The oil circuit system of screw air compressor includes oil tank, oil cooler, oil filter, oil cut valve, temperature control valve, etc.
-
09/17/2020
Sensor basic knowledge and common terms
1. Sensor: a device or device that can sense the prescribed measurement and convert it into a usable output signal according to a certain rule. Usually composed of sensitive components and conversion components. ① Sensitive element refers to the part of the sensor that can be directly (or responded) to be measured.
-
06/14/2020
Refrigerator industry ushered in major changes, compressor refrigeration or history
Refrigerator industry ushered in major changes, compressor refrigeration or history
-
09/01/2021
What is VFD?
A VFD (Variable-frequency Drive, frequency converter) is a power control device that uses frequency conversion technology
-
08/05/2020
Why does the refrigeration compressor produce overheat protection What matters should be paid attention to in the use of overload protector
The working principle and classification of the overload protector. The overload protector of the compressor for air conditioning generally adopts a snap-type bimetallic protector, which consists of a heating wire,
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/13/2020
Danfoss medium temperature refrigeration compressor M series
liquid 1. Liquid back: When the refrigerant returned to the compressor is not a pure gas state, but contains liquid, the influence of the liquid refrigerant on the compressor is negative. If there is too much liquid, it may even cause liquid shock, even if there is no liquid shock, it will happen. Wet compression causes oil to run away.