Type | AC Fan |
Series | DP Series |
Voltage | 220-240 VAC |
Frame Size | 120 mm |
Frame Thickness | 38 mm |
Speed | High |
Bearing Type | Sleeve |
Terminals | Terminal |
Size / Dimension | Square - 119.5mm L x 119.5mm H |
Air Flow | 100.0 CFM (2.80m3/min) |
Static Pressure | 0.350 in H2O (87.2 Pa) |
Noise | 47dB(A) |
Power (Watts) | 21 W |
RPM | 2900 RPM |
Ingress Protection | - |
Operating Temperature | - |
Approval Agency | CE, CUR, TUV, UL |
Weight | 1.03 lbs (467.2 g) |
Power Current (AMP) | - |
Frequency | - |
Housing Material | - |
Power Current(AMP): 0.13/0.12
Power Consumption(WATTS): 22/21
Speed(RPM): 2500/2900
Air Flow(CFM): 85/100
Static pressure(inch-H2O): 0.28/0.35
Noise(dB(A)): 41/47
SUNON Fan DP209WR 2123HST.GN
People who bought this item also viewed
KAKU Fan KA17023HA2
SUNON Fan DP201AT 2122HSL.GN
SUNON Fan A2175-HBT.TC.GN
SUNON Fan SF23092A 2092HBT.GN
SUNON Fan PF80384BX-Q12U-S99
SUNON Fan AB2123-HBL.GN
SUNON Fan EG50060S1-C380-S9A
Sanyo Denki Fan 9GA0412P3J01
APISTEK Fan GA81B2U
Tecumseh Compressor AE4430Y-AA1ASK
OMRON Power Supply S8FS-C01512J
TRIAD Transformer FD6-12
Mitsubishi Circuit Breaker NV100-HP 100A
TE Contactor TYCO PRD11AG0240
Nidec Electric Motor 704K500
Danfoss Sight Glass SGP19SN
CRYDOM Relay ED06C6
KAMCAP Capacitor 25V 1800UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Contactor 3RT2023-1AT60
PIZZATO Switch FM 1314
Rosenberg FAN DD165-120-4
Recent related posts
-
08/16/2020
What factors will cause the cooling performance of water-cooled chillers to decline
Water-cooled chillers are especially suitable for places with abundant water resources. The operation is more stable. It has the characteristics of large single-unit cooling capacity and high cooling efficiency.
-
06/28/2020
Which air conditioners are used by Hitachi compressors
Hitachi compressor technology is mature, good quality, reliable performance, is the first compressor used by Gree, Midea, Chigo, Haier and other air-conditioning manufacturers. okmarts.com is an authorized dealer of Hitachi compressors, with complete specifications and sufficient supply, which can meet your purchasing needs at any time.
-
10/25/2023
Mini Split vs. Window AC: Which Cooling System is Right for You?
Choosing the right cooling system for your home or office is essential for creating a comfortable and pleasant environment. Two popular options are mini-split air conditioners and window AC units. Each system has its unique advantages and considerations.
-
06/20/2020
Common faults and maintenance of air compressor
Common faults and maintenance of air compressor <img src="{{media url="Common_faults_and_maintenance_of_air_compressor.jpg"}}" alt="" /> Common faults and maintenance of air compressor Air compressors are widely used in various industries with the development of technology, but no matter what type of air compressor, there will be some problems in the process of use. The following editors will now introduce some common faults and maintenance methods, let's take a look.
-
06/13/2020
Screw compressor oil system workflow and common faults
Screw compressor oil system workflow and common faults 1. Working process of screw refrigeration unit The working process of screw refrigeration unit can be divided into refrigerant process and oil system process. Friends who are familiar with screw uni 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ـ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/12/2022
Differences between a Sensor and an Actuator
A sensor is a detection device that can sense the measured information, and can transform the sensed information into electrical signals or other required forms of information output according to certain rules to meet the requirements of information transmission
-
03/06/2023
Selection Guide of Air Cylinder: Types and Characteristics
Air cylinder is used in many positioning, driving and clamping applications.
-
07/15/2020
What you need to know about the electrical connection of Copeland refrigeration compressors
Please pay attention to the direction of the terminals in the junction box (single-phase: R, S, C; three-phase: T1, T2, T3). In order to ensure the normal start-up and operation of the Copeland refrigeration compressor, the power supply voltage cannot be lower than 10% of the Copeland compressor rated voltage.
-
08/18/2020
Reasons for the high low pressure value of the chiller
In the application of industrial refrigeration, the chiller is used in conjunction with production and processing equipment, so it runs for a long time. If the customer lacks professional maintenance and routine equipment maintenance for the chiller in daily life
-
09/06/2022
How to Select Overflow Valve
The nominal pressure of the overflow valve is determined by the operating pressure, the service temperature range of the safety valve is determined by the operating temperature