There is no price at present, you can Request a Quote
Fan Type | DC Fan |
Series | M Series |
Voltage | 24 VDC |
Frame Size | 60 mm |
Frame Thickness | 25 mm |
Frame Material | - |
Bearing Type | Vapo |
Speed | Low |
Function | AutoRestart |
Size | 60 mm x 25 mm x 60 mm |
Power Current | - |
Power Consumption (WATTS) | 530 mW |
Speed | 3100 RPM |
Air Flow | 16 CFM (0.45 m3/min) |
Static Pressure | - |
Noise | 16.7dB(A) |
Termination | Wire Leads - 2 |
IP Rating | - |
Approval Agency | - |
Operating Temperature | - |
Weight | - |
We can also provide the following models
GB0538ANV3-A
MF60150S1-10000-G99
EE45102S1-10000-Q99
VF38561S3-0000-F99
MF60100V3-10000-Q99
SF23080A2083LSL.GN
PMD2409PHV3-A
PMB1297AOV1-A
PMB2412AGB1-AY
PMD4838PLB4-A
GB0506AFB1-A
PMB1235ATB4-A
PMD1212PNB4-A
GB2404PNVX-A
PMB4801AKV2-AY
SF11580AT1093XBL.GN
EE50101B4-0000-G99
GB4812PGB3-A
GB2497PHV3-AY
GB2403PWB4-AY
PMB1235ALV3-AY
HA30102B2-10000-999
HA92252B3-10000-A99
MF92251V1-10000-C99
MF50151S1-1B000-C99
EE40204S4-10000-F99
PMB4804POVX-A
GB4809AYVX-AY
PMB0512PMB3-AY
EE40100B2-10000-F99
MF40064B1-0000-H99
PF60761V2-0000-H99
GB2401PHV4-AY
PMD1297AKVX-A
GB1202AHV4-A
EF50152B4-B000-H99
GB2438AQB2-A
GB0506PGB1-A
GB0505AOB3-AY
ME45100V3-10000-G99
MF60250V2-10000-999
PMB2445PTB3-AY
PF40562V3-10000-G99
GB4838PQV2-A
PMB1217AFV2-A
MF17084S4-10000-H99
GB4802ATV3-A
PMD4801PGB1-A
PMD1212PBB3-A
PMD4805AYB3-A
PMB0545PQV4-A
For more information,please contact us freely
SUNON Fan MF60252V3-1000U-A99
There is no price at present, you can Request a Quote
People who bought this item also viewed
Nidec Fan C35129-51API
SUNON Fan MF25060V1-1000U-A99
SUNON Fan EEC0382B3-0000-A99
SUNON Fan AB1123-HBT.GN
SUNON Fan MF40102VX-Q00U-A9D
Delta Fan EFB1524VHG-5A63
SUNON Fan MG75090V1-C070-S9A
Ebmpapst Fan 4600Z
Sanyo Denki Fan 109-150
Bristol Compressor H21R483CBC
COSEL Power Supply CBS1004828-RT
ABB Circuit Breaker 10142870
Schneider Contactor LC1N25004B7N
BROAD-OCEAN Electric Motor Y6S443B211
VICKERS Filter V2682B2C05
Danfoss Sight Glass SGP16SN
Honeywell Controller Module PUL6438S
HELLA Relay 4RA931774.02
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Ebmpapst Fan 8318HL
FRAKO Capacitor 63V 100uf
CHANTO Air Cylinder JUK16X20
Recent related posts
-
09/07/2020
The most common problems and solutions of adsorption dryers!
Adsorption dryer is a very important part of the compressed air purification process. Whether it operates normally and whether it is running well is directly related to the quality of compressed air.
-
06/14/2020
Danfoss cocuses on providing energy efficient, sustainable and smart refrigeration compressors for a varied range of commercial applications such as cold rooms
-
06/25/2020
Basic knowledge of air energy
At present, the most commonly used vapor compression heat pumps, compressors, evaporators, condensers, and throttle valves are the four main components. Other auxiliary components include fans, four-way valves, liquid storage tanks, gas-liquid separators, copper pipes, and Protectors and electronic control parts used to ensure the normal operation of the machine, etc. Direct-heating models also include a water flow regulating valve. Schematic diagram of commercial air source heat pump system
-
07/16/2020
Three factors determine the quality of cold storage
The size of the cold storage should be designed according to the highest amount of agricultural products to be stored throughout the year. This capacity is calculated based on the volume that the stored products must occupy in the cold storage, plus the aisles between the rows, the space between the stack and the wall and ceiling, and the gap between the packaging.
-
09/10/2020
Summary of features and failures of scroll compressors Deep analysis
The scroll compressor is a positive displacement compressor, and multiple compression chambers are formed by the meshing of the scroll rotor and the scroll stator. With the translation and rotation of the vortex rotator, the volume of each compression chamber continuously changes to achieve gas inhalation and compression.
-
12/16/2022
Classifications of SD Cards
As a type of memory cards, Secure Digital card is referred to as SD card. It outperforms CF card and early SM card in terms of security.
-
08/11/2020
The load calculation formula of computer room air conditioner
The load calculation formula of computer room air conditioner<br></br> How to obtain heat and cooling load in the computer room and how to calculate the cooling capacity required in the constant temperature and humidity room.
-
09/09/2020
What are the problems of traditional air compressors compared with frequency conversion air compressors
Variable-frequency air compressors have certain advantages in many aspects, so what are the problems of traditional air compressors compared to variable-frequency air compressors? Today I will tell you about the problems of traditional air compressors.
-
07/23/2020
How to reduce the discharge temperature of refrigeration compressor
The refrigeration compressor is the core and heart of the refrigeration system. The capacity and characteristics of the compressor lead to the capacity and characteristics of the refrigeration system. In a sense, the design and matching of the refrigeration system is to reflect the capacity of the compressor.
-
06/14/2020
Design and selection of compressor unit for mobile cold storage
1. Regardless of the brand selection of the compressor unit, it is determined according to the evaporation temperature of the active cold storage and the effective working volume of the cold storage. In addition, the condensation temperature of the frozen 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ