UNIVER Solenoid Valve CP-9320
People who bought this item also viewed
UNIVER Solenoid Valve Coil DA-0106
UNIVER Solenoid Valve Coil DC24V
Hitachi Compressor ASH280TV-08CU
Honeywell Sensor T7414A1008
SMC Solenoid Valve/Coil SF4-7FC-30
Schneider Contactor LC1F800MW
WINMOST Overflow Valve SVC-03T-3A
PARKER Filter 270L122A
Danfoss Sight Glass SG12N
Nichicon Capacitor NC 400V 3900VF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch FD 2279-M2
NORGREN Air Cylinder RT/57240/M/80
AirTAC Air Cylinder ACP50X80
SMC Solenoid Valve VP4170-124TL
Sanyo Denki Fan 109P0405H904
NORGREN Air Cylinder RM/92050/M/5
NMB-MAT Fan 2410ML-05W-B20
Recent related posts
-
08/20/2020
Introduction of solenoid valve and troubleshooting method
1. Symptoms-the solenoid valve does not open possible reason: 1 The coil has no voltage. 2 Incorrect voltage/frequency 3 Coil burned out 4 Pressure
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/14/2021
Do you know these 10 questions about air conditioning?
Fluorine deficiency: If the air conditioner in your home is an old-fashioned air conditioner that has been used for a long time, it may be because the Freon refrigerant in the air conditioner is gone, and you can continue to use it only by adding Freon. 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧֖ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
07/21/2023
Heat Pump vs Air Conditioner: Which One is Right for You?
When it comes to cooling your home, you have two main options: a heat pump or an air conditioner. Both of these systems work to keep your home comfortable during hot weather, but there are some key differences between the two.
-
09/01/2022
Advantages of a Permanent Magnet Contactor
The permanent magnet contactor is a new type of low-voltage switchgear. Using the working principle of electromagnetic operation and permanent magnet holding
-
09/11/2020
Discussion on the Key Technology of DC Inverter Air Conditioner Control
Inverter air conditioners have become a hot spot for the development of air-conditioning companies because of their energy-saving, comfortable, and high-energy-efficiency advantages and conform to the national policy of "energy saving and emission reduction".
-
06/14/2020
Air conditioning with fresh air Is it useful
Air conditioning with fresh air Is it useful 2020 is a year where you can write a strong sum in history. The epidemic ushered in at the beginning of the year directly affected the industry.
-
06/29/2020
What are the causes treatment and prevention methods of compressor liquid blow
What are the causes, treatment and prevention methods of compressor liquid blow Liquid blow means that the refrigerant liquid or wet steam is sucked into the compressor by the compressor due to failure or insufficient absorption of heat, which is called liquid blow. First, the main reasons are as follows:
-
08/19/2020
Different types of condensers have different layout requirements
There are several types of condensers: vertical, horizontal, spraying and evaporating, which should be arranged according to different types of cold storage. The installation height of the condenser must ensure that its liquid flows into the liquid reservoir under self-flow conditions.
-
09/06/2020
Application of synthetic compressor oil
At present, synthetic lubricants are widely used in the compressor field. Among them, oil-injected and oil-immersed rotary screw air compressors and large reciprocating compressors are one of the most used markets. For example, the sales volume of synthetic compressor oil in Western Europe was 6000t in the late 1980s, and it rose to 10000 in the early 1990s. The sales volume in the United States has exceeded 15,000 tons, and it is increasing at a rate of more than 10% per year.