especially for machine tools
Suitable to carry liquids such as water, coolant, light oil and other clean, non aggressive matters
Operating pressure:Max. 10 kg/cm²
Liquid temperature range:0 ... 90 degrees Celsius
WALRUS Water Pump TPAK4-25
People who bought this item also viewed
WALRUS Water Pump TPK4T8-8
MINAMOTO Water Pump YLGB40-16
PROCON Water Pump 113S100F31GC095
MINAMOTO Water Pump YLGB50-18
Burgmann Mechanical Seal H7N-90
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Eaton Contactor DILM12-10(230V50HZ
PARKER Filter G02819
SIEMENS Servo Motor 1FL6092-1AC61-0AA1
EACO Capacitor SHB-900-15-4F
Syntron Electric Motor 56BYG250B
Recent related posts
-
07/17/2020
Difference between original and refurbished Emerson Copeland Scroll compressor
Difference between original and refurbished Emerson Copeland Scroll compressor Now the most important thing for customers to buy compressors is whether they are genuine. Nobody wants to buy a fake machine after spending money. Here, we briefly introduce how to distinguish the authenticity of the Copeland compressor.
-
09/05/2020
What is the basis for the rated flow when selecting the filter
When selecting a filter, the rated capacity should not be selected according to the diameter of the pipe, but the nominal flow of the filter (nameplate flow) should be selected according to the volumetric flow of the compressed air passing through the filter.
-
06/29/2020
Introduction of measures for compressor pressure protection
Introduction of measures for compressor pressure protection Measures for compressor pressure protection include the following: 1. Control of suction and exhaust pressure When the compressor is running, due to the system or the compressor itself, the discharge pressure may be too high or the suction pressure may be too low. For this reason, the suction and discharge pressures need to be controlled.
-
05/06/2022
10 Matters When Installing Water Solenoid Valve?
Solenoid valve is one of the commonly used valves in automatic control system. It is favored by users because of its low price, simple use, convenience and reliability.
-
07/15/2020
How to avoid overheat protection of scroll Copeland compressor
Friends who have used Copeland compressors know that Copeland compressors are relatively solid to use and are not so easily damaged. This is because Copeland compressors have several built-in protection programs. Overheat protection is one of them. Today we will talk about the internal temperature protector of the scroll compressor.
-
01/02/2024
High Performance Solution for Medical Equipment Cooling (SANYO San Ace G Proof Fan)
Nowadays, cooling fans have been used in all walks of life, from simple electronic devices to high-end intelligent products, smart homes, car seat cushions, medical equipment, etc.
-
08/14/2020
The reason why the fan of air-cooled chiller does not run
In many areas where water sources are lacking, or air-cooled chillers for cooling and cooling of supporting machinery and equipment, after several years of use, such and other small failures may occur.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/17/2020
How to clean the central air conditioning system
Many companies need the central air conditioner of the all-in-one machine to cool the equipment. If the equipment takes a long time or if one of the accessories in the system is broken, we need to replace it. If the equipment is used for a long time, many impurities will remain in the system.
-
08/24/2020
What to do if the air conditioner protection light is flashing and not cooling
In the entire home repair industry, what can quickly arouse the attention of users is the previous TV repair, and the current air conditioning repair is also one.