Maximum flow(L/min): 60
Maximum working pressure(Mpa): 31
Maximum allowable back pressure(Mpa): 16
Maximum commutation frequency(times/min): 240
Spool types: 2 positions
Wiring method: DIN socket method
Coil voltage: AC 220V/50Hz
WINMOST Solenoid Valve WD-G02-B2B-A2-N
People who bought this item also viewed
WINMOST Solenoid Valve WD-G03-B2A-A2-N
MAC Solenoid Valve 275B-780ENAR
Daikin Solenoid Valve JRP-G02-1-N-30
KOGANEI Solenoid Valve F10T1-R-PS
Endress Hauser Transmitter CM42-MAA001EAZ00
Festo Solenoid Coil MSW-110AC-OD
SMC Proportional Valve ITV2050-31N2S2
FESTO Check Valve GRLA-1/4-QS-8-RS-D
HENGYI Vane Pump 150T-48-LR
LEEMIN Filter HX-10-P31
CAREL Expansion Valve Coil E5VSTA0000V
SPRAGUE Capacitor 325P106X6440M30P3Q
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Delta Fan AFB0948HH-R00
Recent related posts
-
07/20/2020
How to judge the starter of the refrigerator compressor is broken
1. The heavy hammer starter, the part that is easily damaged is the poor contact of the start contact. During the measurement, the weight starter can be removed and measured with a multimeter ohm block according to the original installation direction.
-
07/10/2020
Hitachi central air conditioners are really strong. A few words about how powerful are Hitachi compressors
Hitachi central air conditioners are really strong. A few words about how powerful are Hitachi compressors. I saw many articles about Hitachi compressors, various parameters and terminology, and simply summarized the following points
-
09/07/2020
Standard summary of threads in the pneumatic industry
Threads are used to deal with machinery every day, especially hydraulic and pneumatic. For a long time, domestic and foreign, metric and imperial, straight cone, sealed and unsealed, inner and outer, 55 degrees and 60 degrees .
-
08/20/2020
The main difference between air-cooled chillers and water-cooled chillers
First of all, it is necessary to find out which types of chillers are divided into: General manufacturers will produce two types of water-cooled and air-cooled chillers.
-
06/13/2020
What to do if the refrigeration compressor is damaged
What to do if the refrigeration compressor is damaged After the refrigeration compressor in the refrigeration system is damaged, the new compressor cannot be replaced directly because there may be some incentives for the refrigeration compressor to be da 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령
-
09/09/2020
What are the criteria for the selection of air compressors
When choosing an air compressor, we actually need to pay attention to some principles, so that we can compare and choose the one that is more suitable for us. Today, the company will give the company that needs an air compressor, etc., let’s talk about what we should pay attention to when choosing an air compressor. matter.
-
09/11/2020
What are the tips for using screw air compressors
The set unloading pressure of the air compressor pressure regulator is adjusted with the upper adjusting bolt. Turn the bolt clockwise to increase the unloading pressure, and rotate it counterclockwise to reduce the unloading pressure. The differential pressure value is adjusted by the differential knob at the bottom. Turn it counterclockwise, the pressure differential value of the air compressor decreases, and clockwise
-
02/21/2024
HVAC Blowing Cold Air in Winter: Reasons & Ways to Fix
Winter is upon us, and there's nothing more uncomfortable than expecting your HVAC system to provide a warm refuge from the cold, only to find it blowing cold air. This unexpected issue can leave homeowners frustrated and chilly.
-
09/21/2020
Application of synthetic lubricating oil in processing and hydrocarbon gas presses
1. Hydrocarbon and process gas compressor lubricants Historically, hydrocarbon, chemical processing and inert industrial gas compressors have used traditional mineral oil-based lubricants. However, mineral oil cannot meet the needs of many modern rotary compressor designs and other complex applications. A typical gas processing application is at an outflow temperature of 80-1100C and a pressure of 7-70barg.
-
06/13/2020
Is PVC or PE good for domestic fresh air system pipes
Is PVC or PE good for domestic fresh air system pipes Fresh air system is a category of light equipment and heavy design. Fresh air equipment is highly dependent on design and construction.