It is applied to many fields, like Industrial Industrial transport (non-car & non-light truck) Enterprise systems Enterprise projectors Personal electronics Tablets .
And the main parameters of this part is: Spartan-6 FPGA, 480 Max User I/O, Speed Grade-3, Logic Cells 101261, FGG484, RoHS.
Additionally, it is green and compliant to RoHS (Lead free / RoHS Compliant).
XILINX IC Integrated Circuit XC6SLX100-3FGG484I
People who bought this item also viewed
Omron PLC CJ1W-CT021
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Ingersoll Rand Sensor 22823199
VICKERS Filter V0411B8C20
MINDMAN Air Cylinder MCJQ2-12-12-10M
Recent related posts
-
09/06/2020
Characteristics and Control of Exhaust Noise of Air Distribution Valve in Pneumatic System
In a pneumatic system, the air intake and exhaust of the cylinder are controlled by an air distribution valve, and the noise generated by the air discharged into the atmosphere through the exhaust port of the distribution valve is often greater than the noise generated by any part of the pneumatic system. And cause serious damage and pollution to the operators and the surrounding environment [2].
-
07/17/2020
The effect of insufficient refrigerant charge on the chiller
1. If the suction pressure and discharge pressure of the compressor are lower than the normal value, then you need to check to see if it is due to insufficient refrigerant charge.
-
06/25/2020
Compression refrigerator
A refrigerator that relies on a compressor to increase the pressure of a refrigerant to achieve a refrigeration cycle. Compression refrigerator is composed of compressor, condenser (condenser), refrigeration heat exchanger (evaporator), expander or throttle mechanism and some auxiliary equipment. The compressor is its core equipment.
-
03/22/2022
How to Replace a Circuit Breaker?
A circuit breaker is a switching device connected to an electrical circuit that interrupts the current flow when it is excessive.
-
07/17/2020
refrigerating system
4.1 Pressure vessels and pipelines are often contacted by refrigeration and air-conditioning technicians;; components of various systems; for example, placing an R--22 refrigerant storage tank on the rear panel of a car with a common barrier; The hot summer sun can make the temperature of the steel pipe reach 110F; the total area of
-
01/07/2021
Today in the air-conditioning market is tomorrow for fresh air systems
Today in the air-conditioning market is tomorrow for fresh air systems Now we have a fresh air system for work and life, so that even if we are in a closed building environment, we can breathe fresh air. In fact, today's fresh air system has also gone 器2 䀀
-
08/19/2020
Can the fresh air system, air purifier and air conditioner replace each other
1. Fresh air system Fresh air system is based on the use of special equipment on one side of a closed room to send fresh air to the room, and then discharge from the other side by special equipment to the outside,
-
08/20/2020
How to adjust the energy of the compressor of the screw chiller
The compressors used in screw chillers generally have brands such as Taiwan Hanbell and German Bitzer, which belong to the screw compressor series. An obvious feature of this type of compressor is that it can perform an energy adjustment action on it according to different
-
07/18/2020
A coup to avoid the oil return problem of the refrigeration compressor of the piston chiller
Compressor: It is a complex machine running at high speed. Ensuring adequate lubrication of moving parts such as compressor crankshafts, bearings, connecting rods, pistons, etc. is the basic requirement for maintaining the normal operation of the machine. For this reason, compressor manufacturers require the use of specified grades of lubricating oil, and require regular inspection of the lubricating oil level and color
-
03/23/2023
Common Faults, Reasons of Faults, and Solutions of Vacuum Pump
common faults like falling vacuum degree, abnormal operation, even being jammed, large noises and oil leakage resulting from not well-sealed pump body appears in the operation