There is no price at present, you can Request a Quote
Yageo Resistor RC2512JK-076M2L
There is no price at present, you can Request a Quote
People who bought this item also viewed
Delixi Fuse RT16-00 32A
IDEC Relay RU4S-CD1-D24
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron Switch Z-01HD
HONGFA Relay HF41F-24-Z8SG
Fuji Fuse FCK2-600
vickers Gear Pump GPA3-40-E-20R6.3
Ferraz Shawmut Fuse NH000GG50V25
Panasonic Light Curtain SF4B-H20C
Recent related posts
-
01/10/2021
Don't understand the compressor It's enough to see these
Don't understand the compressor It's enough to see these Many people say that buying an air conditioner means buying a compressor. This is true. Simply put, the quality and life of the compressor determine the attitude of most people to buy. So what are 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/23/2020
Installation foundation of compressed air pipeline
Basic knowledge is very important for sheet spray work, and the same is true during equipment installation. When installing compressed air pipelines, everyone must pay attention to the following precautions:
-
09/04/2020
Eight core issues warn compressor companies, and the rapid changes in the market cannot be ignored
When we find that the hot companies a few years ago have become traditional enterprises, you will understand how fast we are in an era of change! Most compressor companies now have a very serious sense of crisis-dealers are difficult to manage
-
05/12/2022
6 Considerations When Selecting PLC?
The operating functions of PLC include logic operation, timing and counting functions. The simple operating functions include data shift, comparison, etc
-
08/11/2020
Correct adjustment method of opening degree of thermal expansion valve
The expansion valve is one of the four major components of the refrigeration system. It is an important device for regulating and controlling the flow and pressure of the refrigerant entering the evaporator, and it is also the "boundary line" between the high and low pressure sides.
-
02/17/2021
How about the cooling effect of the air-conditioning fan
Air-conditioning fans are becoming more and more popular in summer. Of course, the price of air-conditioning fans is cheaper than air-conditioning. Of course, the cooling effect is not comparable to that of air-conditioning. So what about the cooling effect of air-conditioning fans? This is also a problem that everyone is more concerned about. In addition, the principle of the air-conditioning fan is also what you want to know. Let's take a look at the cooling effect of the air-conditioning fan with the editor, for your reference.
-
08/19/2020
Precautions during use of industrial chiller compressor
One of the most important components in industrial chillers is the compressor. Compressor damage means that the chiller is scrapped. Therefore, the compressor is a very important consideration when choosing a chiller.
-
08/08/2022
Squirrel Cage Induction Motor Vs Wound Rotor Induction Motor: Rotor Structure, Pros and Cons
The three-phase induction motor consists of two basic parts: the stator and the rotor.
-
09/08/2020
Comparison of direct drive and belt drive of air compressor
The two transmission modes of air compressors are direct gear transmission and transmission through a certain medium, namely belt transmission, generally speaking, direct drive and belt transmission.