Type | Rotary Servo Motors Without Gears |
Series | Sigma-7 SGM7A Series |
Rated Output | 600 W |
Voltage | 200 V |
Serial Encoder | 24-bit absolute |
Rotation Speed | 3000 RPM - 6000 RPM |
Specifications | Straight with key and tap |
Options | With holding brake (24 VDC) |
Time Rating | Continuous |
Thermal Class | UL |
Vibration | 15μm |
Withstand Voltage | 1500VAC 1 min |
Insulation Resistance | 500VDC, 10MΩ minimum |
Enclosure | - |
Ambient Temperature | 0 to 40ºC |
Ambient Humidity | 20 to 80% (non-condensing) |
Excitation | Permanent magnet |
Drive Method | Direct drive |
Mounting | Flange-mounted |
Yaskawa Servo Motor SGM7A-06A7A6C
People who bought this item also viewed
Yaskawa Servo Motor SGMGV-09ADA61
Yaskawa Servo Motor SGM-08V3B4
Yaskawa Servo Motor SJME-01AMA41
Yaskawa Servo Motor SGMGH-20DCA6H-OY
Lenze Servo Motor MDSKSRS071-33
Sanyo Denki Servo Motor L850T-012
Yaskawa Servo Motor SGMRS-55A2A-YR21
ESTUN Servo Motor EMJ-08AFB22
Mitsubishi Servo Drive MR-J2S-10B-PY096
Rockwell A-B HMI 2711P-T12C15B1
Honeywell Actuator NOM-P1A-E
COSEL Power Supply LFA150F-36-CJ1
Schneider Analog output module PLC TSXASY800
JSCC Reduction Drive 80YS25GV22
Kuroda Module A21PB-16U-2Y04
FLUKE Battery TI20 - RBP
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Mitsubishi PLC FX3S-14MT-ES
AVC Fan DD12038B12HP
AirTAC Air Cylinder TN32X170S
SANDVIK Welding Wire SANDVIK 25.20.L
HIWIN Linear Guideway HGH25CAC
MAHLE Filter LA1321
Recent related posts
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
09/15/2020
Matching selection for small internal compression process design
As a traditional process type, small internal compression process equipment has been produced in the okmarts.com factory for many years. It is well received by users for its inherent advantages.
-
06/14/2020
Central air-conditioning unit classification
Central air-conditioning unit classification The central air conditioning unit is the core part of the central air conditioning system. Reasonable selection of units is very important for a central air-conditioning project. Regarding the cooling mode and 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄
-
08/17/2020
Detecting and repairing methods for problems in shell and tube condensers
Since the central air conditioner is a kind of refrigeration equipment, it must be equipped with a condenser, and most of them are shell and tube condensers. When the device has been used for a long time, some inconveniences may occur.
-
03/15/2021
ALPHA Alpha Servo Drive Repair
Common faults of Alpha servo drives include: power-on without display, with display without output, overcurrent, overvoltage, undervoltage, overheating, overload, overspeed, phase loss, jitter, encoder abnormality, module damage, ground fault, parameters Errors etc.
-
06/14/2020
The Package of Compressor and H series Gas Turbine
The Mitsubishi Hitachi Power Systems H-100 100 MW Class twin shaft gas turbine is ideally suited as a main refrigeration compressor driver for 4 to 6 mtpa LNG plant
-
07/20/2020
What brand of refrigerator compressor is the best? Ranking of eight refrigerator compressor brands
Do you know what is the most important part of the refrigerator? Of course, it is the compressor. The refrigerator can work normally because of it. It can be said that the compressor is the core component of the refrigerator.
-
08/14/2020
Reasons for internal protection of industrial chiller compressors
There is a thermal switch inside some compressors. The function of this switch is to disconnect the power supply line to the compressor motor when the temperature of the compressor exceeds the set value.
-
03/12/2021
Four control modes of servo drive
1.Feedback compensation open loop control. The accuracy of open-loop system is low, because the step error , start stop error and mechanical system error of servo driver will directly affect the positioning accuracy. This system has the advantages of both open-loop and closed-loop, that is, it has the stability of open-loop and the accuracy of closed-loop.
-
09/14/2020
Analysis of common failures of air-cooled compressors (1)
There are three common failures in the main components of air-cooled compressors: 1. Failure of the gas circuit system 2. Failure of the oil circuit system 3. Failure of the transmission mechanism. Do some system analysis below