Circuit breaker 22 A rated current 22 A, n tripper 260 A, used for starter combination, screw
Pattern connection, standard switching capacity
Product brand name SIRIUS
Product Name Circuit Breaker
The specification of the product is used for starter combination
Product type name 3RV6
Comprehensive technical data
Structural dimension S0 of circuit breaker
The loss power W totals 8 W typically
The measured value is 690 V at AC when the pollution degree of isolation voltage is 3
The measured value of impulse voltage resistance is 6 kV
Protection level IP
IP20 on the front
connection terminal IP20
dent resistance
comply with IEC 60068-2-27 25g/11 ms
environmental conditions
The installation height is higher than the horizontal plane
the maximum value is 2 000 m.
Ambient temperature
-20 ...+60 c during operation
-50 ...+80 C during transportation
Relative air humidity during operation 10 ... 95%
main circuit
The number of poles is used for the main circuit 3
Working voltage
the measured value is 690 V
the maximum measured value is 690 V at AC-3
The measured working frequency is 50 ... 60 Hz
Measured value of working current 22 A
Working current
AC-3 AC-3
measured value 22 A at 400v
Switching frequency
the maximum value at AC-3 is 15 1/H.
Protection and monitoring functions
Working short circuit current (Ics) breaking capacity AC
the measured value at 400v is 25 kA
Breaking capacity of limit short circuit current (Icu)
the measured value at 400 V at AC is 55 kA
Current action value
286 A of short circuit release without delay
Protection device to prevent short circuit from causing damage to switching device.
Product function short circuit protection yes
Specification of short circuit release magnetic
Mounting/fixing/outline dimensions
The loading position is arbitrary
Fastening type: screw fastening and snap fastening on 35mm mounting rail according to DIN EN 60715
Height 97 mm
Width 45 mm
Depth 96 mm
Siemens Circuit Breaker 3RV6321-4CC10
People who bought this item also viewed
Fuji Circuit Breaker EW32AFC-2P015
Siemens Circuit Breaker 3RV2021-0JA10
Siemens Circuit Breaker 3RV1021-1KA10
Siemens Circuit Breaker 3RV2011-4AA10
Siemens Circuit Breaker 3VL7712-2SB36-0AA0
Terasaki Circuit Breaker S1000-CE
Siemens Circuit Breaker 3RV1021-1HA10
ABB Circuit Breaker E1N16 R1250A SACE PR121
Siemens Circuit Breaker 3VA1463-5EF32-0AA0
TRIAD Transformer F-215U
Schneider Contactor LC1D09E7
OBO Surge Protection Device MC 50-B-OS
Ferraz Shawmut Fuse DN00GB69V40D1L
SAWANA Relay SHZ1-A8(ST8A) AC12V/21c
Siemens Resistor JJY:023422620001
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TOWA SEIDEN Switch CA-A1WA-200
Omron PLC CS1W-CN523
COSEL Power Supply PBA300F-36-GF4
Recent related posts
-
06/20/2020
Common fault phenomena, causes and elimination methods of piston compressors
Common fault phenomena, causes and elimination methods of piston compressors Common faults of piston compressor (1) Phenomenon: the compressor cannot start Reasons: 1. Electrical circuit failure; 2. High and medium voltage relay and oil pressure relay are disconnected.<img src="{{media url="Common_fault_phenomena_causes_and_elimination_methods_of_piston_compressors.jpg"}}" alt="" />
-
11/02/2023
What is a Rotary Screw Air Compressor? Everything You Need to Know
Rotary screw air compressor (screw air compressor, screw type air compressor, rotary screw compressor), is a positive displacement air compressor
-
08/08/2020
Reasons for condensation at the bottom of the condenser
Reasons for condensation at the bottom of the condenser 1. It is abnormal if condensation occurs at the bottom of the condenser when the unit is running. It may be the reason for the low amount of refrigerant.
-
09/11/2020
Ways to reduce bearing noise
Ways to reduce bearing noise (1) Method of using chemical additives Adding certain chemical additives to the bearing lubricant can reduce bearing noise. For example, a low-noise grease containing noise-reducing additives produced by a factory in Tianjin can reduce bearing noise by 3.9-9.2dB from the original basis. , Suitable for use in miniature or small bearings.
-
11/19/2023
Difference in 2 Pin, 3 Pin and 4 Pin Computer Fans: Which is better?
If a computer does not have a radiator, its internal temperature will be infinitely high, and eventually the hardware will be burned directly. Whether it is for the CPU, graphics card, chassis, or power supply, heat dissipation is required.
-
02/16/2023
Installation and Maintenance of Gearbox
When you select gearbox model, four factors should be given comprehensive consideration.
-
08/14/2020
Maintenance method of ultra-low temperature chiller refrigeration system
An ultra-low temperature chiller refers to a refrigeration unit whose chilled water temperature reaches below minus 35°C. The unit adopts two-stage compression refrigeration.
-
07/12/2022
How to Use an Air Compressor
Air compressors enable the usage of pneumatic tools, which make DIY work a breeze. Compressors are also beginner-friendly, since assembling one is as simple as plugging in the hose and electrical cord.
-
07/13/2022
What is Air Compressor
An air compressor is a pneumatic device that converts power (using an electric motor, diesel or gasoline engine, etc.) into potential energy stored in pressurized air (i.e., compressed air).
-
12/08/2021
Differences Between Smart Pressure Transmitter and Analog Pressure Transmitter
Pressure transmitter is composed of single chip microcomputer and micro displacement (differential) pressure sensitive element, which can complete multi-function detection and conversion from non electric quantity to electric quantity.