There is no price at present, you can Request a Quote
Type | Semi-Hermetic Compressors |
Body Type | 6D Compressor |
Compressor Cooling | Discus |
Motor Rating Power | 35 HP |
Phase | Three Phase |
Electrical | 200-3 |
Copeland Compressor 6DN3A3500-TSE-001
There is no price at present, you can Request a Quote
People who bought this item also viewed
Daikin Compressor JT100GCVDKW@SB
Mitsubishi Compressor RB173NPF
Hitachi Compressor BSA645DT-R1EN
Tecumseh Compressor RK5480Y
Copeland Compressor DKLP-15X-EWL
Copeland Compressor ZR125KC-TF5-522
Copeland Compressor ZR34KH-TFD-522
Copeland Compressor ZP182KCE-TW5-550
Hitachi Compressor TH508SG-C9EU
Danfoss Compressor MTZ64HM4BVE
Huaguang Compressor ATA72XL
Hitachi Compressor 303DHV-47B2
TRIAD Transformer F7-10
Saginomiya Expansion Valve ATX-71160DUS
Fuji Contactor SC-E1P-G
Sanyo Denki Fan 109P0612T7H142
EMERSON Sight Glass AMI-1MM3
SAMYOUNG Capacitor 63V 22UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CHELIC Air Cylinder JGD32*75-B
Yaskawa Servo Motor SGMGV-05ADA21
TOYOOKI Gear Pump TCP3-F20-MR1-B
Recent related posts
-
08/20/2020
How to calculate air conditioner power-what is air conditioner power
The cooling power of the air conditioner refers to the total power consumed within the rated time when the air conditioner is in cooling operation, and the unit is W. It should be noted that the cooling power and cooling capacity are different.
-
07/28/2020
Common faults and solutions of screw chillers
Low voltage overrun protection:<br></br> Solution: Replace or clean the filter element; clean the suction port filter.<br></br> Dirty or ice blockage at the inlet of the expansion valve:<br></br> Solution: Dirty blockage: remove the expansion valve and clean it. Ice blockage: replace the filter drier and run again
-
08/02/2020
Why do some compressors have to soft start
We know that the motor's direct starting current is 4 to 7 times the rated current, so if the power of the motor is relatively small, then the impact on the grid is not great, we allow it to start directly, generally the motor power is allowed below 7.5KM Started directly
-
08/13/2020
Adding method of refrigerant in central air conditioner
How to add refrigerant to central air-conditioning, what operating methods do you know? Let’s take a look with the editor of okmarts.com today!
-
06/22/2020
Why is the air conditioner not cooling
Why is the air conditioner not cooling There are many factors for not cooling, for example: the selected air conditioner does not match the area of the room; improper installation of the air conditioner will cause the air circulation of the air conditioner to be unsmooth; when the indoor temperature is relatively high, the air conditioner cannot be cooled when turned on; It has been aging, or the service life has expired; the air conditioner has not been cleaned for a long time, and the filter surface is covered with dust; and the freon of the air conditioner has been seriously lacking. <img src="{{media url="magefan_blog/Why_is_the_air_conditioner_not_cooling.jpg"}}" alt="" />
-
10/13/2023
Samsung Refrigerator Ice Maker Not Working: Common Causes and Solutions
If you own a Samsung refrigerator, you may rely on its ice maker to provide you with a steady supply of ice cubes. However, like any other appliance, the ice maker in your Samsung refrigerator can sometimes experience issues that prevent it from producing ice.
-
01/05/2021
Real Gas Model for an Electric Swashplate Refrigeration Compressor
Real Gas Model for an Electric Swashplate Refrigeration Compressor Author links open overlay panelMohammadArqam1Dzung VietDao1AmirJahangiri2MarkMitchell2PeterWoodfield1 1 School of Engineering and Built Environment, Griffith University, Australia 2 U 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
08/09/2020
The harm of overheating of industrial water chiller to equipment during use
The overheating problem of industrial chillers has a serious negative impact on the efficiency of the equipment. In order to maintain the safety and stability of industrial chillers, when using industrial chillers,
-
11/26/2021
Why DC 4~20mA is Chosen for Signal Transmission of Transmitters?
In industry, it is necessary to measure all kinds of electric and non electric parameters, such as current, power, temperature, pressure, speed and angle, etc.
-
09/14/2020
Troubleshooting of high pressure air compressor
1-0.27/150 Type High Pressure Air Compressor Troubleshooting Method Fault Features Sound in the crankcase Possible cause a. The screw and nut of the connecting rod are loose. Whether the big-end bearing of the connecting rod is loose.