There is no price at present, you can Request a Quote
Body Type | CR Compressor |
Product Type | Copelaweld |
App | HT |
Capacity BTU/HR | 49300 |
EER BTU/WH | 9.9 |
Freq | 60Hz |
Phase | 3Ph |
Voltage | 208/230 |
Ref | 22 |
Copeland Compressor CRN5-0500-TFV-230
There is no price at present, you can Request a Quote
People who bought this item also viewed
Tecumseh Compressor TRK5480Y
Bristol Compressor H29B32UABCA
Carrier Compressor 06DR241BCC06C0
Mitsubishi Compressor LNB42FSCMC
Copeland Compressor ZR125KC-TF5-522
Copeland Compressor QR90K1-TFD-521
Copeland Compressor ZR36K3-PFJ-522
Copeland Compressor CRNQ-0500-TFD-598
GMCC Compressor PH150X1C-4DZDE3
Hitachi Compressor ASG151RDNB7BT
Sanyo Compressor C-RV214H2NC
Danfoss Compressor MT64HM4DVE
TRIAD Transformer F56-650
carrier Expansion Valve 034G1709
Siemens Contactor 3RT1065-6AT36
Sanyo Denki Fan 9G0948H202
LIMING Electric Motor CM08IG25SBVB
LEEMIN Filter DFX-850-20
Danfoss Sight Glass SGI6
MUNDORF Capacitor 250V 10UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Hossoni Power Supply CWY-3-6000VA
UniOhm Resistor 1206W4F820KT5E
Schneider Contactor LC1D323BL
IRC Resistor RNC65J9093FS
Recent related posts
-
01/03/2021
Danfoss expansion valves
New Design for Danfoss T2/TE2 Danfoss has implemented a new patent registration design to protect our expansion valve and the applications of our customers against counterfeit products. Take a closer look at the valve body and you will see that it has 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧֢ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
08/20/2021
Things You Need to Know about Refrigerator Compressor Hot
A lot of people are worried about whether the compressor overheating is due to refrigerator quality problems.
-
09/08/2020
Compressed air filter selection method and related technical parameters
In the air compressor system, the air processed by the air compressor cannot be used directly. It must be purified by the dryer filter before it can be put into the air equipment. The role of the filter in the air compressor system is to remove liquid water, dust, oil, dust and other impurities in the compressed air.
-
09/25/2023
Chilled Water System: Basics, Working Principle Diagram, Types and More
A chilled water system is a type of HVAC (heating, ventilation, and air conditioning) system that provides cooling through the circulation of chilled water.
-
08/02/2020
Characteristics of R12, R22, R407C refrigerants in cold storage
don’t know if you still remember that okmarts.com wrote "How to Choose Refrigerant for Cold Storage Design" some time ago. Today okmarts.com will introduce several different cold storage refrigerants in detail, namely R12, R22, R407C
-
07/15/2020
About the built-in pressure relief valve (IPR valve) of Copeland compressors
About the built-in pressure relief valve (IPR valve) of Copeland compressors Among the built-in protection devices of Copeland compressors ZB15-ZB48, ZF06-ZF25, there is a small pressure protection device called built-in pressure relief valve (IPR valve). Below we briefly talk about the work of the built-in pressure relief valve.
-
08/08/2020
Reasons for condensation at the bottom of the condenser
Reasons for condensation at the bottom of the condenser 1. It is abnormal if condensation occurs at the bottom of the condenser when the unit is running. It may be the reason for the low amount of refrigerant.
-
08/20/2020
Installation and placement conditions of cooling tower of thermal shock tester
Let's learn about the installation and placement conditions of the cooling tower of the thermal shock tester with the editor of okmarts.com! 1. The ground is flat and well ventilated;
-
06/24/2020
Why is the air conditioner not cooling
1.Check whether the compressor is working normally. If the compressor is broken, the air conditioner cannot start normally and there will be no cooling effect. 2. There is not enough refrigerant in the air conditioner. At this time, you need to add Freon, and the time for adding Freon can be very long. 3. The air conditioner itself has quality problems and the electrical components have failed. In this case, you need to find a master to repair it.
-
06/30/2020
Broken suction valve of Bristol compressor
Broken suction valve of Bristol compressor A Bristol compressor is a machine that compresses gas. Generally, the piston compresses gas 1450 times per minute (half-sealed compressor) or 2900 times (full-sealed compressor), that is, the time to complete an intake or exhaust process is 0.02 seconds or even shorter.