There is no price at present, you can Request a Quote
Product Type | Scroll |
App | AC |
Capacity BTU/HR | 85500 |
EER BTU/WH | 11.8 |
Freq | 60Hz |
Phase | 3Ph |
Voltage | 460 |
Ref | 22 |
Copeland Compressor ZR84KC-TFD-455
There is no price at present, you can Request a Quote
People who bought this item also viewed
Daikin Compressor 2YC45ZXD
Tecumseh Compressor RK5512Y-NA3A
Tecumseh Compressor AHA2490ZXG
Mitsubishi Compressor TNB306FPNMC-L
Copeland Compressor ZPI72KCE-TFD-420
Copeland Compressor ZR11M3E-TWD-561
Copeland Compressor ZR61KCE-TFD-522
KONOR Compressor GP14TG
Sanyo Compressor C-9RVN393H0V
Bitzer Compressor 4NCS-20.2-40P
Panasonic Compressor 2P17C3R225A
TRIAD Transformer VPL26-1800
Saginomiya Expansion Valve VPX-3415DHC
Schneider Contactor LP4K0901BW3
Nidec Fan D05F-12BM
Foyo Electric Motor FY56EM300A
PARKER Filter 937757Q
Danfoss Sight Glass SGI 16S
MURATA Capacitor DEA1X3A470JN2A
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SCHNEEBERGER Linear Guideway BMD45-G0V1
Eaton Vickers Vane Pump 4520V-50A11-1CC22R
Recent related posts
-
03/02/2021
Connection between Arduino and servo motor
The connection of the servo motor using Arduino is as follows: Connect the black wires on the two servo motors to the GND on the Arduino Connect the red wires on the two servo motors to the 5V pin on the Arduino Connect the yellow wire on the first motor to pin 8 on the Arduino
-
07/23/2020
FAQs about refrigeration compressors, do you know these?
Why control the impurity content and moisture content of the compressor and air conditioning system? Impurities entering the friction surface of the moving parts in the compressor pump body will cause abnormal scratches and wear. Impurities entering the solenoid valve, expansion valve, control valve, capillary tube and stop valve in the refrigerator system will block the valve hole or make the valve close tightly. And fail.
-
01/11/2021
[Case] Air conditioner compressor does not work after Mitsubishi Pajero overhaul Failure phenomenon:
[Case] Air conditioner compressor does not work after Mitsubishi Pajero overhaul Failure phenomenon: The Mitsubishi Pajero off-road vehicle uses a 6G72 engine. The air-conditioning compressor does not work after the car is overhauled and the condenser 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁
-
12/20/2021
Battle of Giants - Differences of PLC by Siemens, Allen-Bradley and ABB
Many industrial equipment manufacturers in the world are producing PLC. The product and market competition between different companies is unavoidable.
-
09/07/2020
What happens if the air compressor uses three filters and one oil for an extended period of time
The "three filters and one oil" of the air compressor have a specified service life, which is generally replaced after 2000 hours of use. If you continue to use it beyond the service period, it will bring a lot of harm to the normal operation of the air compressor,
-
04/24/2023
How to Change Air Compressor Oil (5 Steps)
Air compressor oil is mainly used for the lubrication of the moving parts in the compressor cylinder and the exhaust valve, and plays the role of anti-rust, anti-corrosion, sealing, sound reduction and cooling.
-
06/21/2020
Composition principle of refrigeration system of refrigerator
Composition principle of refrigeration system of refrigerator Refrigerators have a larger cooling capacity than household refrigerators, and there are more refrigerants filled in the system. Therefore, a liquid storage tank is installed on the pipeline between the condenser and the filter, and a shut-off valve is installed on the tank to shut down the system for a long time. When closing the shut-off valve, the refrigerant liquid is stored in the tank.<img src="{{media url="Composition_principle_of_refrigeration_system_of_refrigerator.jpg"}}" alt="" />
-
07/28/2020
Simple and clear-graphic analysis of central air conditioning cleaning
Simple and clear-graphic analysis of central air conditioning cleaning<br></br> Three steps for central air conditioning cleaning: air outlet first, air return, focus on cleaning the filter<br></br> 1. Clean the air outlet<br></br> Adjust the swing leaf of the air outlet panel of the indoor unit to a level, and wipe the outer air outlet of the room with a clean towel. If you want to clean the inner louver, you need to remove the air outlet and clean it.
-
08/20/2020
How much is the temperature of the industrial chiller to prevent condensation
Condensation water in the industry is mainly caused by the large temperature difference between the ambient temperature and the cooling water temperature of the chiller.
-
08/09/2020
Rosemount 3144P temperature transmitter FF fieldbus manual!
power supply Rosemount temperature transmitter FOUNDAIION fieldbus uses standard fieldbus power supply. The operating voltage of the transmitter is 9 to 32Vdc with a maximum of 11 mA. The rated voltage at the transmitter end is 42.4V dc, Wiring diagram