Connections:Gasket mount type
Nominal diameter:1/4
Spool operating method:Spring center type
Maximum operating pressure MPa {kgf/cm2}:35 {350}(25 {250}) *1
Maximum flow rate L/min:100
Permissible back pressure MPa {kgf/cm2}: 17.5 {175}
Maximum switching frequency times/minute
AC, DC:240
With rectifier:120
With built-in surge killer DIN connector type with lamp:100
External coating protection:IEC Pub529 IP65
Daikin Solenoid Valve LS-G02-2CB-30-EN
People who bought this item also viewed
Daikin Solenoid Valve KSO-G02-2AB-30
Daikin Solenoid Valve JRP-G02-1-N-30
Daikin Solenoid Valve KSH-G04-3CC-20
Daikin Solenoid Valve KSO-G03-3CC-20
CHELIC Solenoid Valve SV-6101-L
Mitsubishi Compressor HNB78FAC-YBC
TRIAD Transformer FS28-200
Contrinex Sensor LLK-3031-204
PARKER Overflow Valve DSDU
CAT Piston Pump 2510
MAHLE Filter LX3316
Danfoss Sight Glass SG19N
SCHNEIDER Capacitor BRS186AXID23B48
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
IFM Sensor O8P204
PIZZATO Switch FD 693-F2
Recent related posts
-
06/13/2020
Do you know the two methods of evacuating the refrigeration system?
Do you know the two methods of evacuating the refrigeration system? Vacuuming is an indispensable important process before charging refrigerant in the production or maintenance of refrigeration equipment. The process of removing the non-condensable gas a 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥
-
09/08/2020
Compressed air filter selection method and related technical parameters
In the air compressor system, the air processed by the air compressor cannot be used directly. It must be purified by the dryer filter before it can be put into the air equipment. The role of the filter in the air compressor system is to remove liquid water, dust, oil, dust and other impurities in the compressed air.
-
08/25/2020
The cleaning and maintenance of the chiller is of great care in autumn and winter!
How to ensure the normal operation of our chiller equipment in the cold winter? Now I will explain to you the relevant precautions and maintenance methods of the chiller when the ambient temperature is harsh in winter.
-
11/21/2021
Benefits of Rosemount Fieldbus Transmitter
It is reasonable to say that Rosemount fieldbus transmitter series can help customers reduce the overall cost of the system.
-
07/23/2020
Analysis of common failure causes of hermetic refrigeration compressors
1. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.<br></br>
-
01/26/2022
A Quick Look at the Submersible Pressure Transmitter
Submersible pressure transmitters use imported chip assembly, reflecting the superior technology. Their structure is compact and firm and is light for installation.
-
12/06/2022
How to Maintain a Linear Guideway?
Linear guideways are precision transmissions and require careful maintenance in order to give full play to their functions and prolong their service life. The followings are tips for the maintenance of the liner guideway
-
06/15/2020
Reasons for refrigerator compressor not working
Reasons for refrigerator compressor not working Reason one: Is the external power supply and compressor input voltage normal? Check whether the power supply and compressor input voltage meet the standard requirements (187 volts to 242 volts), whether 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦
-
08/10/2020
Refrigerant classification and selection requirements
Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south. It is a working substance that continuously circulates in the refrigeration system and realizes refrigeration through its own state changes.
-
03/01/2023
The Types of Air Cylinder and Notices for Use
Air cylinder is a tube-shaped metal mechanical part that guides the piston to do linear reciprocating motion in its insides.