Stroke: 10 mm
Piston diameter: 10 mm
Type code: DFC
Drive unit operating mode: Yoke
Cushioning: Elastic cushioning rings/pads at both ends
Mounting position: Any
Guide: Recirculating ball bearing guide
Design: Guide
Position sensing: For proximity sensor
Symbol: 00991737
Operating pressure: 1 bar - 10 bar
Max. speed: 1 m/s
Mode of operation: Double-acting
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC): 0 - No corrosion stress
Ambient temperature: -5 to 60 Celsius Degree
Impact energy in the end positions: 0.05 J
Max. torque Mx: 0.3 Nm
Max. payload as a function of the stroke at defined distance xs: 9.8 N
Theoretical force at 6 bar, retracting: 35 N
Theoretical force at 6 bar, advancing: 47 N
Moving mass: 27.2 g
Moving mass at 0 mm stroke: 27.2 g
Product weight: 100 g
Additional moving mass per 10 mm stroke: 7.2 g
Pneumatic connection: M5
Cover material: Wrought aluminum alloy
Seals material: NBR
Housing material: Wrought aluminum alloy
Piston rod material: High-alloy stainless steel
Festo Air Cylinder DFC-10-10-P-A-KF
People who bought this item also viewed
MINDMAN Air Cylinder MCRPLF-90-25-500
Festo Air Cylinder ADVU-20-15-A-P-A
Festo Air Cylinder KADVB-25-20-APA
Festo Air Cylinder DGP-40-1050-PPV-A-B
Festo Air Cylinder DSNU-50-50-P-A
MINDMAN Air Cylinder MCMA-11-16-25
Festo Air Cylinder DNC-63-80-PPV-A
MINDMAN Air Cylinder MCSF-8-10
SHAKO Air Cylinder PC20B450
UNIVER Solenoid Valve K1000500125M
Belimo Actuator GR230A-7
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
FUJITSU Relay FTR-LYCA006V
SMC Solenoid Valve SY7120-4GZ-02
SHAKO Air Cylinder JC16B25-H
P+F Pepperl Fuchs Sensor OBT20-R2-E0
Recent related posts
-
09/10/2020
How to choose the specifications of the air compressor
Once the air volume (m3/min) and pressure (Mpa(G)) requirements of the factory's air consumption are determined, the specifications of the air compressor can be selected. Factors you may want to consider when choosing include:
-
03/21/2023
The Operation and Maintenance of Vacuum Pump
About 20 minute’s operation should be done in advance before vacuum pump starts to vacuumize assembling unit. And after oil temperature rises, open extraction valve of assembling unit to extract unit.
-
09/06/2020
The harm of poor quality air filter element to screw air compressor
Inferior air compressor air filters are those that are relatively rough in workmanship and have the same filtering effect. You must know that air filters are the protective umbrella for the heart of the screw air compressor (screw host). If the picture is cheap, use inferior air compressors.
-
05/08/2022
How to Clean Automobile Solenoid Valve?
Before removing the valve body from the bottom of the transmission, take extra care when removing the flat wire of the external solenoid valve.
-
08/21/2020
Useless for a lifetime. Dehumidification and refrigeration of air conditioners are completely different!
This summer, the heavy rain that has come in New York caught many friends off guard, and the humid and sultry weather made the big guys complain. A small partner told the author that at this time, dehumidification is enough. The air conditioner does not need to be cooled. principle of refrigeration of central air-conditioning chillers
-
08/07/2020
What is the temperature control range of industrial chillers and how to set the temperature
Industrial chillers are commonly used refrigeration equipment in the industrial refrigeration industry. They are characterized by a wide range of types, complete models, affordable prices, special customization, and a wide range of applications.
-
03/16/2021
FANUC spindle drive repair fault treatment
FANUC spindle drive maintenance problems mainly appear as stalls, abnormal speeds, motor oscillations, jitter during processing, and main circuit overcurrent alarms. Compared with AC FANUC spindle drive maintenance problems, the primary manifestations are motor overvoltage, fuse blown, etc.
-
09/09/2020
Talking about the development process and use situation of Chinese vacuum drying equipment
Since ancient times, humans have been accustomed to drying materials with natural heat sources and natural ventilation. Until now, some rural areas still use solar heat to dry materials. Although these natural methods are energy-saving and environmentally friendly, it is an indisputable fact that production efficiency is low.
-
04/17/2022
Why Electromagnetic Flowmeter Needs Grounding?
Before discussing grounding, I want to give you a question: what is grounding? We usually talk about all kinds of grounding including protection grounding, shielding grounding, working grounding, signal grounding and so on.
-
08/14/2020
Factors affecting the boiling heat transfer of refrigerant liquid
In the evaporator, the heat of the cooled medium is transferred to the refrigerant through the heat transfer wall, so that the liquid refrigerant absorbs heat and vaporizes.