There is no price at present, you can Request a Quote
Piston diameter: 25 mm
Type code: DGPI: DGPL: DGP: DGPIL
Cushioning: Pneumatic shock absorber, hard characteristic curve: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Guide: Recirculating ball bearing guide: Sliding guide: Heavy-duty guide: Basic guide
Driver principle: Positive locking (slot)
Position sensing: With integrated linear potentiometer: For proximity sensor: With linear potentiometer attached
Variants: Supply port at both ends: Clamping unit, bottom version: Protected version: Standard slide: Extended slide: Front clamping unit: Rear clamping unit
Operating pressure: 2 bar - 8 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb X
Explosive ambient temperature: -10Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 2 (ATEX): Zone 1 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:-:-]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 1 - Low corrosion stress: 0 - No corrosion stress: 2 - Moderate corrosion stress
Degree of protection: IP65
Ambient temperature: -10 to 60 Celsius Degree
Cushioning length: 18 mm
Theoretical force at 6 bar, retracting: 295 N
Theoretical force at 6 bar, advancing: 295 N
Alternative connections: See product drawing
Pneumatic connection: G1/8
Note on materials: Free of copper and PTFE
Cover material: Cast aluminum: Coated
Seals material: NBR: TPE-U(PU)
Housing material: Anodized: Aluminum
Festo Air Cylinder DGP-25-940-PPV-A-B
There is no price at present, you can Request a Quote
People who bought this item also viewed
CHANTO Air Cylinder JUR25X15
AirTAC Air Cylinder JSI100X400S
STNC Air Cylinder TGC80x50-S
Festo Air Cylinder DGC-K-25-150-PPV-A-GK
Festo Air Cylinder DSEU-40-80-P-A
Festo Air Cylinder DGP-32-1150-PPV-A-B
Festo Air Cylinder ADVUL-20-10-P-A
Festo Air Cylinder DPZJ-25-80-P-A-S2
Festo Air Cylinder DGC-18-700-G-PPV-A
Festo Air Cylinder ADVU-32-40-A-P-A
SHAKO Air Cylinder IC100B175
Belimo Actuator BLF24-T-ST
SMC Proportional Valve ITV2010-32N2N4
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
DANFOSS Switch RT30AW
Daikin Piston Pump V50A2RX-95
COMAIR ROTRON Fan PD24B2
Recent related posts
-
08/11/2020
The load calculation formula of computer room air conditioner
The load calculation formula of computer room air conditioner<br></br> How to obtain heat and cooling load in the computer room and how to calculate the cooling capacity required in the constant temperature and humidity room.
-
06/14/2020
Newly installed air conditioner, it trips when plugged in, what's going on
Newly installed air conditioner, it trips when plugged in, what's going on This question is about the problems that occur when the newly purchased appliances are used for the first time.
-
03/08/2022
What’s the Difference between Semi-Hermetic Compressors and Hermetic Compressors?
In the hermetic compressor, the motor and the compressor share the main shaft (reciprocating type)
-
08/30/2022
How to Calculate the Breaking Capacity?
The breaking capacity of the circuit breaker is an important indicator of the circuit breaker, which refers to the ability of the circuit breaker to safely cut off the fault current. There are 36KA, 50KA and other specifications.
-
08/02/2021
Mitsubishi Heavy Industries - Haier Vs. Toshiba Commercial Air Conditioners
Because of the acceleration of urbanization, commercial air conditioners have developed rapidly in recent years.
-
07/26/2020
Why is the refrigeration compressor always overheating protection?
Compressor overheating protection means to protect the compressor motor from being burned. When the motor temperature or the compressor's own temperature exceeds a certain value, some built-in or external protection devices are used to disconnect the compressor's working power supply to achieve protection The role of the compressor.
-
06/14/2020
Introduction to screw refrigeration compressors and precautions for use (technical sharing)
Introduction to screw refrigeration compressors and precautions for use (technical sharing) Screw refrigeration compressors and piston refrigeration compressors have the same gas compression method, and both belong to volumetric compressors, which means 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ڬ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
03/12/2021
Composition of servo drive system
The controller is usually a computer or PID control circuit, and its main task is to transform and process the deviation signal output by the comparison element, so as to control the executive element to act as required.
-
09/04/2020
Do you know the classification of commonly used filters
The impurities contained in the compressed air of the pneumatic system are divided into four categories: solid dust, moisture, oil mist and odor. In order to meet the requirements of different industrial sectors on the quality of compressed air,
-
08/15/2020
The main cause of cold storage fire is cold storage installation or cold storage construction
In recent years, we have seen a lot of news about cold storage fires. Once a cold storage causes a fire, it will not only cause economic losses to us, but also may cause safety problems.