07/31/2020
What are the specific operation methods for maintenance of screw compressors in cold storage
Before the cold storage screw compressor must be overhauled, if possible, unload the slide valve to the "0" position, shut down normally, and cut off the power supply.
-
08/15/2020
What should I do if wall cracks appear after the cold storage is built
After the construction of the cold storage project, there may be many problems. For example, we have seen a lot of news recently. It is said that the wall cracks appeared after the construction of the cold storage
-
09/04/2020
The difference between air compressor inverter and soft starter
Soft starter concept Soft start (also known as soft starter, motor soft starter, soft starter) Soft start is a novel motor control device that integrates motor soft start, soft stop, light load energy saving and multiple protection functions.
-
08/05/2020
How to choose the distance between cold storage air coolers
As the evaporator commonly used in the refrigeration system, the air cooler directly affects the efficiency of the refrigeration system. As we all know, the air cooler will use different fin spacings according to the required ambient temperature.
-
08/08/2020
The cold water (freezing) machine displays the reverse phase loss fault quick troubleshooting
The cold water (freezing) machine shows a reverse phase loss fault, which is a common fault of abnormal power supply. The reason for this failure is simple, and it is very convenient to repair, as long as there is a little electrician foundation, it can bﰨ2 䀀 湠疖
-
08/20/2020
The main difference between air-cooled chillers and water-cooled chillers
First of all, it is necessary to find out which types of chillers are divided into: General manufacturers will produce two types of water-cooled and air-cooled chillers.
-
07/26/2023
Heat Pump Makes Loud Noise When Turning Off: Causes and Solutions
A heat pump is an essential part of many homes, providing both heating and cooling to keep the indoor environment comfortable. Like any other appliance, it can sometimes develop issues that require attention. One common problem that homeowners may face is a heat pump making loud noise when turning off.
-
06/30/2022
Types of Check Valve
Depending on the design of the check valve, they will operate slightly differently. The most common check valve is a spring loaded in-line check valve, however, we will discuss multiple types below.
-
07/25/2020
This is the "3 times", "8 steps" and "5 keys" of central air conditioning installation~~
It is not an exaggeration to say that the central air conditioner is installed with 3 points and 7 points for quality. The central air conditioner needs to be properly matched with the interior decoration. In fact, the equipment itself is only a "semi-finished product".
-
02/18/2020
The principle of central air conditioning refrigeration
The principle of central air conditioning refrigeration The liquid Freon enters the evaporator through the capillary. The space suddenly increases and the pressure decreases. The liquid Freon will vaporize and absorb a lot of heat. The evaporator will become cold. The indoor unit fan will remove the indoor air from the evaporator. Blow through, so the cold air blows out from the indoor unit. Let's take a look at the cooling principle of the central air conditioner with the editor for your reference<img src="{{media url="magefan_blog/The_principle_of_central_air_conditioning_refrigeration.jpg"}}" alt="" />